Product Details

Model NO.
COVERED ACSR CONDUCTOR
Current
DC Cable
Insulation Material
XLPE
Sheath Material
Crosslinking
Material Shape
Round Wire
Wire Core Material
AAC, AAAC, ACSR
Certification
ISO, CCC, CE
Model
Covered ACSR Conductor
Brand
Hongda Cable
Conductors
Stranded, AAC (1350-H19)
Inner Insulation
Natural Color (PE) or XLPE
Outer Insulation
PE or XLPE
Voltages
13.8kv - 46kv
Transport Package
Sold in Full Rolls or Cut to Specification
Specification
100sqmm, 150sqmm
Trademark
N/A
Origin
China
HS Code
8544601200
Production Capacity
500000 M Per Week

Product Description

Product Description

 

COVERED CONDUCTOR FOR MV LINES

Covered aluminum conductor steel reinforced for self-supporting system

Aluminum conductor Steel reinforced, water blocked, semi-conductor, XLPE layer, HDPE outer sheath (resistant to external conditions and to tracking).

Aluminum conductor steel reinforced The conductor shall be stranded circular (IEC 61089), based upon aluminum wires stranded around a core of steel wires. The number of wires per conductor and their diameter shall be as described on table.

1.1 Aluminum conductor steel reinforced

The conductor shall be stranded circular (EN 50182), based upon aluminum wires stranded around a core of steel wires.

The different layers conforming the conductor shall be stranded so that adjacent ones shall have opposite direction of lay and the outer layer shall be right-hand.

1.2 Semi-conductive screen

It shall consist of a fully bonded layer of black semi-conductive cross-linked compound. It shall be extruded over the conductor to provide a smooth surface without causing any damage to the conductor.

The conductor screen minimum thickness measured and accepted at any point shall not be less than 0,32 mm. In addition, the average of all the measures shall not be less than the nominal thickness (0,4 mm).

1.3 Outer sheath

1.3.1 Insulating layer

The first layer of the sheath is the insulating layer (not being the same level of insulation as a standard insulated cable). The insulation layer shall be applied by a suitable extrusion process, simultaneously with the semiconductive screen, and shall form a compact and homogenous body. In addition, it shall be possible to remove it without creating any damage to the conductor.

This layer shall be built in XLPE compliant with IEC 60502-2 characteristics, with nominal thickness as described in table follows. The minimum thickness measured and accepted at any point of the insulation layer shall not be less than 90% of the nominal value minus 0,1 mm.

1.3.2 Protective layer

The second layer will be an extruded covering layer and will provide resistance to adverse weather conditions, electrical tracking, ultraviolet radiation and mechanical abrasion. It shall be adhered to the insulating layer. Besides the characteristics indicated herein, the material shall be compliant with Polyethylene designation ST7 as described in standard IEC 60502-2.

The minimum thickness measured and accepted at any point of the protective layer shall not be less than 90% of the nominal value minus 0,1 mm.

 
Nominal voltage UMax (kV) Nominal Thickness Screen (mm) Minimum Thickness Screen (mm) Nominal thickness outer sheath (mm) 
XLPE HDPE
15 0.4 0.32 1.5 1.5
25 0.4 0.32 2.0 2.0
35 0.4 0.32 3.8 3.8

Aluminium conductor steel reinforced – ACSR – BS

AL1/ST1 (British Standard)

EN 50182

old: BS 215-Part 2

name actual section cond. Ø cond. Weight appr. calc. breaking force calc. cond. resistance. constr steel steel section constr. AL AL section
  EN 50182 mm kg/km kN Ohm/km mm mm² mm mm²
MOLE 10 4,5 43 4,1 2,702 1/1,50 1,77 6/1,50 10,62
SQUIRREL 20 6,33 85 7,9 1,370 1/2,11 3,49 6/2,11 20,94
GOPHER 25 7,08 106 9,6 1,093 1/2,36 4,37 6/2,36 26,24
WEASEL 30 7,77 128 11,4 0,908 1/2,59 5,27 6/2,59 31,61
FOX 35 8,37 149 13,2 0,783 1/2,79 6,11 6/2,79 36,66
FERRET 40 9,0 172 15,2 0,677 1/3,00 7,07 6/3,00 42,41
RABBIT 50 10,05 214 18,4 0,543 1/3,35 8,81 6/3,35 52,88
MINK 60 10,98 255 21,8 0,454 1/3,66 10,53 6/3,66 63,18
SKUNK 60 12,95 465 53.1 0,456 7/2,59 37.03 12/2,59 63,18
BEAVER 70 11.97 302 25,7 0,383 1/3,99 12,47 6/3,99 74,82
HORSE 70 13,95 538 61,2 0,394 7/2,79 42,80 12/2,79 73,37
RACCON 75 12,30 320 27,2 0,362 1/4,09 13,20 6/4,09 79,20
OTTER 80 12,66 339 28,7 0,342 1/4,22 13,98 6/4,22 83,88
CAT 90 13,50 386 32,7 0,301 1/4,50 15,90 6/4,50 95,40
HARE 100 14,16 425 36,0 0,273 1/4,72 17,50 6/4,72 105,0
DOG 100 14,15 394 32,7 0,273 7/1,57 13,50 6/4,72 105,0
COYOTE 125 15,89 522 46,4 0,219 7/1,91 20,09 26/2,54 132,1
COUGAR 125 15,25 419 29,8 0,221 1/3,05 7,24 18/3,05 130.3
TIGER 125 16,52 602 58,0 0,220 7/2,36 30,59 30/2,36 131,1
WOLF 150 18,13 726 69.2 0,183 7/2,59 36,88 30/2,59 158,0
DINGO 150 16,75 506 35,7 0,181 1/3,35 8,80 18/3,35 158,7
LYNX 175 19,53 842 79,8 0,157 7/2,79 42,77 30/2,79 183,4
CARACAL 175 18,05 587 41,0 0,156 1/3,61 10,24 18/3,61 184,3
PANTHER 200 21,00 974 92,2 0,136 7/3,00 49,49 30/3,00 212,0
JAGUAR 200 19,30 671 46,6 0,136 1/3,86 11,69 18/3,86 210,6
LION 225 22,26 1.095 100,6 0,121 7/3,18 55,65 30/3,18 238,5
BEAR 250 23,45 1.213 111,1 0,109 7/3,35 61,60 30/3,35 264,0
GOAT 300 25,97 1.489 135,7 0,089 7/3,71 75,67 30/3,71 324,3
SHEEP 350 27,93 1.718 155,9 0,077 7/3,99 87,29 30/3,99 374,1
ANTELOPE 350 26,73 1.411 118,2 0,077 7/2,97 48,37 54/2,97 373,1
BISON 350 27,00 1.444 120.9 0,076 7/3,00 49,49 54/3,00 381,8
DEER 400 29,89 1.971 178,5 0,067 7/4,27 100,2 30/4,27 429,3
ZEBRA 400 28,62 1.621 131,9 0,067 7/3,18 55,59 54/3,18 428,9
ELK 450 31,50 2.19 198,2 0,061 7/4,50 111,3 30/4,50 477,0
CAMEL 450 30,15 1.797 145,7 0,061 7/3,35 61,60 54/3,35 475,2
MOOSE 500 31,77 1.999 161,1 0,055 7/3,53 68,53 54/3,53 528,7

 

 

→ Other cross-sections on request.
Technical values can change. No responsibility is therefore taken for correctness.

 

Description

The conductors are stranded,circular compressed aluminum. The conductor screen is the extruded Semi-conducting conductor shield in Black. The inner Insulation is mainly natural color thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE). And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black or Grey with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.

After Sales Service

 

For more product details, please download our PDF files or contact with Vivian.

We are China Covered ACSR Conductor 150sqmm Dingo 100sqmm Dog XLPE Insulated Covered Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION