Solidal Cable 0.6/1kv 10mm2 16mm2 with 4 X Cu Wires

China Solidal Cable 0.6/1kv 10mm2 16mm2 with 4 X Cu Wires  manufacture and supplier

Solidal Cable 0.6/1kv 10mm2 16mm2 with 4 X Cu Wires image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
SOLIDAL CABLE
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PE
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC
Model
Yjlv
Brand
Hongda
Transport Package
Wooden
Specification
10MM2 16MM2
Trademark
hongda
Origin
Henan/China
HS Code
8544492100
Production Capacity
20km/Day

Product Description

Aerial Concentric Service Cable with Communication Wire

APPLICATIONS OVERVIEW

Hongda Cables supplies a comprehensive range of concentric and split concentric cables manufactured in accordance with standard BS7870. These aluminium and copper cables are devised for use by Distribution Network Operators (DNOs) to provide the final connection to residential properties. Additional functionality includes use for sub-main distribution and within high-rise buildings and street lighting systems.

The choice between Concentric and Split Concentric cable is determined by the supply type: TN-C-S supply for Concentric and TN-S supply for Split Concentric. These are LSZH cables (low smoke zero halogen) with the outersheath suitable for installations requiring a reduction to the risk to human life or sensitive equipment in the event of fire.

CONCENTRIC AND SPLIT CONCENTRIC CABLES

CONCENTRIC CABLES

These cables are used for power supplies with Protective Multiple Earthing (PME) systems, where a combined Protective Earth (PE) and Neutral (N) – together known as the PEN – connects the combined neutral-and-earth to real earth at multiple locations to reduce the risk of electric shock in the event of a broken PEN.

  Aluminium concentric Copper concentric
Conductor Solid aluminium (Class 1) Stranded copper conductor (Class 2)
Insulation XLPE (Cross-linked Polyethylene) XLPE
Concentric conductor Single layer of plain copper wires Single layer of plain copper wires
Outer sheath PVC (Polyvinyl Chloride) PVC

SPLIT CONCENTRIC CABLES

These cables are used when the power supply has separate PE & N conductors and are only combined as PEN near the power source. The Protective Earth and Neutral are not connected after the building entry point.

  Aluminium split concentric Copper split concentric
Conductor Solid aluminium (Class 1) Stranded copper (Class 2)
Insulation XLPE PVC Type TI1
Neutral conductor Plain copper wires (Class 1) covered with blue polymeric insulation Plain copper wires (Class 1) covered with blue polymeric insulation
Earth continuity conductor Plain copper conductor (Class 1) Plain copper conductor (Class 1)
String separator Non-hygroscopic string separator Non-hygroscopic string separator
Outersheath PVC TM1 or LSZH PVC TM1

Voltage: 0.6/1kv.
Operating temperature: Maximum 90°C, minimum -30°C
.