7 Cores 0.75mm2 1.5mm2 2.5mm2 Kvv/Kvvr Control Cable

China 7 Cores 0.75mm2 1.5mm2 2.5mm2 Kvv/Kvvr Control Cable  manufacture and supplier

7 Cores 0.75mm2 1.5mm2 2.5mm2 Kvv/Kvvr Control Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
7 Core 0.75mm2 KVV Control Cable
Application
Overhead
Conductor Material
Copper
Sheath Material
PVC
Insulation Material
PVC
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CE, CCC, RoHS
Insulation
PVC
Cores Number
2 to 61 Cores
Standard
VDE
Quality Guarantee
10 Years
Sheath Color
Black
Mark
Laser Type
Manufacture
Yes
Sample
Yes
Cable Parts
Yes
Conductor
Cu/Al Core
Certificate
CE CCC ISO
Transport Package
Wooden Plate
Specification
0.5-10sqmm
Trademark
Hongda
Origin
China, Henan
HS Code
8544492100
Production Capacity
30000km/Per Months

Product Description

0.6/1kV 7 Core 0.75mm2 KVV Control Cable

  1. Application

Wiring for controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution with rated voltage up to 450/750V(0.6/1KV) A.C .For the operation and control of automation and interconnection between switchboard and machine, including tool machines.

  1. Standards

GB/T9330-2008 ,IEC 60502, etc. we can also design and produce for special application requirement.

  1. Operating features
    1. The maximum permissible continuous operating temperature is 70ºC
    2. The lowest installation temperature of the cable is 0ºC .
    3. Permissible Min. Bending radius not less than 6 times of the

completed cable diameter for unarmoured cable; not less than 12 times of the completed cable

diameter for armoured or copper tape screened cable; not less than 6 times of the completed cable diameter for screened fle xible cable.

  1. Type, descriptions and applications
Chinese Type Descriptions Applications
KVV Copper conductor PVC insulated PVC sheathed control cables For laying indoor, in tunnels, ducts, conduit etc. Permanent place
KVVR Copper conductor PVC insulated and sheathed flexible control cable For laying indoor ,in tunnels, ducts and movable using

 

 

KVVP Copper conductor PVC insulated and sheathed copper wire braiding shielded control cable For laying indoor, in tunnels, ducts, conduit etc. permanent place where shield required.
KVVRP Copper conductor PVC insulated and sheathed copper wire braiding shielded flexible control cable For laying indoor ,in tunnels, ducts and flexible and shield required etc.place ,easy to move
KVVP2 Copper conductor PVC insulated PVC sheathed copper tape shielded control cables For laying indoor, in tunnels, ducts, conduit etc. permanent place where shield required.
KVVP2-22 Copper conductor PVC Insulated PVC Sheathed Copper Tape shielded steel tape armored Control Cables Used in light-current control system and heavy-current magnetic interference region.

KVV22

Copper conductor PVC insulated PVC sheathed steel tape armored control cables For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force

KVV32

Copper conductor PVC insulated PVC sheathed steel wire armored control cables For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force

NOTE:Hongda cable company can produce “Flame-Retardant Series”, “Fire-Resistant Series”, “Low Smoke Halogen Free (LSHF/LSOH) Series”, “Low Smoke Low Halogen (LSLH) Series”, etc. control cable as customer required. Performance in line with IEC60332: 2004 requirements.

 

  1. Production range
Type Rated voltage U0/U Nominal conductor cross section (mm2) Standards
0.75 1.0 1.5 2.5 4 6 10
Number of cores
KVV

450/750V

2~61 2~14 2~10

GB/T9330-2008

KVVR KVVRP 2~61
KVVP2 KVVP 4~61 4~14 4~10
KVV22,KVV32,
KVVP2-22
7~61 4~61 4~14 4~10

Note::Recommended core numbers are 2,3,4,5,7,8,10,12,14,49,24,27,30,37and 61 Construction size and Properties of cable

 

    1. KVVR type, 450/750V(0.6/1kV) Copper Conductor PVC Insulated and Sheathed Control Cable to GB/T9330-2008

 

Number of cores×Nominal cross section
mm2
Nominal thickness of insulation mm Nominal sheath thickness
mm
Average overall diameter mm Max.DC resistance of conductor at 20 ºC Ω/km Approx. Weightof cable kg/km
Limit Caps
2×0.75 0.6 1.2 6.7 8.1 26.0 62.8
2×1.0 0.6 1.2 7.0 8.5 19.5 70.2
2×1.5 0.7 1.2 7.9 9.5 13.3 88.5
2×2.5 0.8 1.2 9.0 10.9 7.98 124.3
2×4 0.8 1.2 9.9 11.9 4.95 160.2
2×6 0.8 1.2 10.8 13.1 3.30 211.3
2×10 1.0 1.7 14.3 17.3 1.91 362.8

 

3×0.75
3×1.0
3×1.5
3×2.5
3×4
3×6
3×10
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.2
1.2
1.2
1.2
1.5
1.7
7.1
7.4
8.3
9.5
10.5
11.5
15.2
8.5
8.9
10.0
11.5
12.7
13.9
18.4
26.0
19.5
13.3
7.98
4.95
3.30
1.91
78.3
88.5
113.7
156.9
208.5
300.4
487.4
4×0.75
4×1.0
4×1.5
4×2.5
4×4
4×6
4×10
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.2
1.2
1.2
1.5
1.5
1.7
7.6
7.9
9.0
10.4
11.4
13.2
16.6
9.2
9.6
10.9
12.5
13.8
15.9
20.1
26.0
19.5
13.3
7.98
4.95
3.30
1.91
93.2
106.3
138.7
202.2
283.9
385.4
615.6
5×0.75
5×1.0
5×1.5
5×2.5
5×4
5×6
5×10
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.2
1.2
1.5
1.5
1.5
1.7
8.2
8.6
9.7
11.3
13.0
14.3
18.2
9.9
10.3
11.7
13.6
15.7
17.3
22.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
106.3
122.5
162.1
253.5
344.3
454.3
750.2
7×0.75
7×1.0
7×1.5
7×2.5
7×4
7×6
7×10
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.2
1.2
1.5
1.5
1.5
1.7
8.8
9.2
10.5
12.8
14.1
15.6
20.3
10.6
11.1
12.7
15.5
17.1
18.8
24.5
26.0
19.5
13.3
7.98
4.95
3.30
1.91
129.2
151.1
204.4
317.0
433.8
585.0
963.0
8×0.75
8×1.0
8×1.5
8×2.5
8×4
8×6
8×10
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.2
1.2
1.5
1.5
1.5
1.7
1.7
9.7
10.2
11.7
14.3
15.8
17.4
22.8
11.7
12.3
14.1
17.2
19.0
21.0
27.5
26.0
19.5
13.3
7.98
4.95
3.30
1.91
144.6
169.4
247.6
357.0
490.1
679.3
1076.8
10×0.75
10×1.0
10×1.5
10×2.5
10×4
10×6
0.6
0.6
0.7
0.8
0.8
0.8
1.5
1.5
1.5
1.5
1.7
1.7
10.8
11.4
13.7
16.0
17.8
20.1
13.1
13.8
16.6
19.4
21.5
24.2
26.0
19.5
13.3
7.98
4.95
3.30
193.4
225.2
303.2
439.5
623.3
849.1

 

Number of cores×Nominal cross section
mm2
Nominal thickness of insulation
mm
Nominal sheath thickness
mm
Average.overall diameter mm Max.DC resistance of conductor at 20 ºC Ω/km Approx. Weightof cable kg/km
Limit Caps
12×0.75 0.6 1.5 11.2 13.5 26.0 218.8
12×1.0 0.6 1.5 11.8 14.2 19.5 256.3
12×1.5 0.7 1.5 14.2 17.1 13.3 347.8
12×2.5 0.8 1.5 16.5 20.0 7.98 508.5
12×4 0.8 1.7 18.7 22.6 4.95 723.8
12×6 0.8 1.7 20.7 25.0 3.30 981.2
14×0.75 0.6 1.5 11.7 14.1 26.0 246.0
14×1.0 0.6 1.5 12.9 15.6 19.5 289.2
14×1.5 0.7 1.5 14.8 17.9 13.3 394.5
14×2.5 0.8 1.5 17.4 21.0 7.98 580.0
14×4 0.8 1.7 19.6 23.7 4.95 827.7
14×6 0.8 1.7 21.8 26.3 3.30 1126.1

 

16×0.75
16×1.0
16×1.5
16×2.5
0.6
0.6
0.7
0.8
1.5
1.5
1.5
1.7
12.9
13.5
15.6
18.3
15.5
16.4
18.8
22.1
26.0
19.5
13.3
7.98
273.5
322.5
441.7
670.7
19×0.75
19×1.0
19×1.5
19×2.5
0.6
0.6
0.7
0.8
1.5
1.5
1.5
1.7
13.5
14.2
16.4
19.6
16.3
17.2
19.8
23.7
26.0
19.5
13.3
7.98
312.8
370.3
509.9
776.8
24×0.75
24×1.0
24×1.5
24×2.5
0.6
0.6
0.7
0.8
1.5
1.5
1.7
1.7
15.6
16.4
19.4
22.8
18.8
19.8
23.4
27.6
26.0
19.5
13.3
7.98
386.2
458.4
653.0
967.6
27×0.75
27×1.0
27×1.5
27×2.5
0.6
0.6
0.7
0.8
1.5
1.5
1.7
1.7
15.9
16.7
19.8
23.3
19.2
20.2
23.9
28.2
26.0
19.5
13.3
7.98
423.2
503.7
718.6
1069.6
30×0.75
30×1.0
30×1.5
30×2.5
0.6
0.6
0.7
0.8
1.7
1.7
1.7
1.7
16.4
17.5
20.0
24.0
19.8
21.0
24.0
28.0
26.0
19.5
13.3
7.98
478.4
568.3
786.7
1174.6
37×0.75
37×1.0
37×1.5
37×2.5
0.6
0.6
0.7
0.8
1.7
1.7
1.7
1.7
18.0
19.0
22.0
26.1
21.5
23.0
26.6
31.5
26.0
19.5
13.3
7.98
569.4
679.2
945.1
1419.0

Control cables – VDE standards

the full portfolio of flexible control cables manufactured in accordance with VDE0250 standards, which includes:

YY cable (YSLY)  Versatile unscreened or unshielded cable suitable for most situations where there is only light mechanical stress
CY cable (YSLCY) Multicore screened flexible cable with Polyethylene Terephthalate (PETP) for electromagnetic interference free-transmission
SY cable (YSLYSY) Flexible shielded cable with galvanised steel wire braid for additional mechanical protection
LiYCY cable Screened and shielded cable for applications where moderate mechanical stress and electromagnetic screening is required
LiYY cable Unscreened and unshielded cable for light duty in dry and humid environments
LiHH cable Unscreened LSZH low capacitance control
LiHCH cable Screened LSZH data transmission cable

Depending on their construction properties, these flexible cables can be suitable for use under light, medium or high mechanical stresses. They also offer various degrees of protection against electrical interference and resistance to caustic substances and oils. 

CY cables, SY cables and YY cables are not suitable for fixed wiring applications requiring compliance with the requirements set out in BS7671.

Packaging&Delivery
 


 

Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 

 

We are China 7 Cores 0.75mm2 1.5mm2 2.5mm2 Kvv/Kvvr Control Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION