Power Cables PVC Insulation 0, 66 Kv Cable Nyy, Nym, Nyby, Nayy, Nayby

China Power Cables PVC Insulation 0, 66 Kv Cable Nyy, Nym, Nyby, Nayy, Nayby  manufacture and supplier

Power Cables PVC Insulation 0, 66 Kv Cable Nyy, Nym, Nyby, Nayy, Nayby image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
PVC insulation Power cables
Current
DC & AC
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Copper or Aluminum
Certification
ISO, CCC, SGS
Model
YJV
Brand
Hongda
Rated Voltage
0.6/1kv, 600/1000V, 1.1kv
Transport Package
500m or 1000m Per Drum
Specification
1.5-300 mm2
Trademark
Hongda or OEM
Origin
China
HS Code
8544492100
Production Capacity
4000 Km / Year

Product Description

Power cables with PVC insulation 0,66 kV – NYY, NYM, NYBY, NAYY, NAYBY

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV at frequency 50 Hz at ambient temperature from -50 °C to +50 °C and relative humidity up to 98% at temperature up to 35 °C, cables are intended for laying in outdoors including. NYM and NAYY-J cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.

Description

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV at frequency 50 Hz at ambient temperature from -50 °C to +50 °C and relative humidity up to 98% at temperature up to 35 °C, cables are intended for laying in outdoors including. NYM and NAYY-J cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.

CONDUCTORS
Copper or aluminum round single-wire or multicore conductors (class 1 in accordance with IEC 60228(2004).

INSULATION AND OVERSHEATH
Insulation and oversheath are made from polyvinylchloride (PVC) compound.

COVERING
IN ACCORDANCE WITH IEC 60229 Armour is made from 2 galvanized steel tapes and PVC compound oversheath is applied over wrapping.

Technical specifications

  Number of conductors Nominal conductor crosssection (mm²)
NYY 1. 2. 3. 4 1,5 – 50
NYM 2. 3. 4 1,5 – 50
NAYY 1. 2. 3. 4 2,5 – 50
NAYM 2. 3. 4 2,5 – 50
NYY 5 1,5 – 25
NYBY,NAYBY 2. 3. 4 4,0- 50

Insulation resistance calculated for 1 km at temperature 20 °C:

Nominal conductor cross-section (mm²) IInsulation resistance, MOhm, no less
1 – 1.5 12
2.5 – 4 10
6 9
10 – 50 7

Insulation resistance calculated for 1 km at
temperature 20 °C indicated at protractedly
permissible temperature for the conductors
heating at operational period at least
0.005 MOhm.
Cables endure AC 3.0 kV test and 50 Hz
frequency during 10 minutes.
Cables are flame retardant with a single
laying.
Manufactured cable length:
– manufactured cable length must be min.

450 m for cables with main conductor crosssection
1.5-16 mm²;
– manufactured cable length must be min.
300 m for cables with main conductor crosssection
25-50 mm².
Minimal temperature of cable laying without
pre-heating: – 15 °C.
Minimum permissible bending radius of the
cable at installation and routing must equal
to min. 10 outer diameters of the cable for
single-core cable, and min.7.5 outer diameters
of the cable – for multicore cables.
 

Permissible current loads and permissible short-circuit currents for cables with copper conductors:

Nominal
conductor
cross-section(mm²)
Permissible current loads (A) Permissible shortcircuit
currents (kA)
  Single-core cables Double-core cables Three-core cables*  
  above
ground
under
ground
above
ground
under
ground
above
ground
under
ground
 
1.5 29 32 24 33 21 28 0.17
2.5 40 42 33 44 28 37 0.27
4 53 54 44 56 37 48 0.43
6 67 67 56 71 49 58 0.65
10 91 89 76 94 66 77 1.09
16 121 116 101 123 87 100 1.74
25 160 148 134 157 115 130 2.78
35 197 178 166 190 141 158 3.86
50 247 217 208 230 177 192 5.23

*The same and for four-core cables with neutral conductor lower cross-section. For determining of current loads (four-core cables) which are
equal to cross-section of four-wire networks in all loads in normal mode this loads must be multiplied by 0.93 coefficient.

Permissible current loads and permissible short-circuit currents for cables with aluminum conductors:

Nominal
conductor
cross-section(mm²)
Permissible current loads (A) Permissible shortcircuit
currents (kA)
  Single-core cables Double-core cables Three-core cables*  
  above
ground
under
ground
above
ground
under
ground
above
ground
under
ground
 
2,5 30 32 25 33 21 28 0,18
4 40 41 34 43 29 37 0,29
6 51 52 43 54 37 44 0,42
10 69 68 58 72 50 59 0,70
16 93 83 77 94 67 77 1,13
25 122 113 103 120 88 100 1,81
35 151 136 127 145 109 121 2,50
50 189 166 159 176 136 147 3,38

*The same and for four-core cables with neutral conductor lower cross-section. For determining of current loads (four-core cables) which are
equal to cross-section of four-wire networks in all loads in normal mode this loads must be multiplied by 0.93 coefficient.

 

More information and other cable inquiry, pls contact Vivian Yuan as follows:

Vivian Yuan
Mobile: +86 158 3829 0725

We are China Power Cables PVC Insulation 0, 66 Kv Cable Nyy, Nym, Nyby, Nayy, Nayby manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , , , , , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION