660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian

China 660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian  manufacture and supplier

660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
vv
Current
DC & AC
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
YJV
Transport Package
in Drum or in Coil
Specification
3*1.5 3*2.5 3*4 4*1.5 4*2.5 4*4 5*1.5 5*2.5 5*4
Trademark
OEM/Hongda
Origin
Henan
HS Code
8544492100
Production Capacity
10000m/Day

Product Description

Application

 

Construction:
1. Conductor – copper, single or multiwire, round- or sector-shaped, 1 or 2 class as per GOST 22483. 
2. Insulation – PVC. Insulated multiconductor cable conductors carry identification coloring. Neutral conductor insulation is blue. Grounding conductor insulation is in two colors (yellow-green). 
3. Twisting – Insulated conductors of two-, three-, four-, and five- conductor cables are twisted. Two conductor cables feature conductors of the same area. Three-, four-, and five- conductor cables feature all the conductors of the same area or one conductor (ground or neutral one ) of a smaller area. 
4. Jacket – PVC, VVng cables are sheathed with flameretardant PVC.

Application:
These cables are intended for distributing electric power in fixed installations rated for nominal alternating voltages of 0.66 KV and 1 KV 50 Hz. They are meant for laying inside both dry and wet industrial premises on special trestles, in assemblies as well as for laying outdoors. Cables are not recommended for burying in trenches.
VVG cables are flameretardant if laid individually.
VVGng cables are flameretardant if laid in bunches.

       
     
 

Technical details:
Type of climatization UHL, allocation category – 1 and 5 as per GOST 15150-69.
Operating temperature range………………………-500 to +500
Relative humidity of air…………………………..up to 98%
Cables shall be laid and installed without preheating at temperatures not lower than …-15
Minimum bending radius when laid: VVG single conductor cables………………………… 10 outer diameters
VVGng single conductor cables………………………….15 outer diameters
Multiconductor cables………………………………..7.5 outer diameters
Rated frequency…………………………………50 Hz
Testing alternating current voltage 50 Hz
For 0.66 KV……………………3 KV
For 1 KV……………………………………….3.5 KV
Continuously permissible conductor operating heating temperature…..…+70

Construction

 

1. Copper conductor

2. XLPE insulation

3. PP filling material

4. PVC outer sheath black

 

Properties

 

Max. admissible conductor temperature:  90 °C

Service temperature: – 20 … + 90 °C

Min. Laying temperature: – 5 °C

Min. bending  radius:

Multicourse: 12 x D

Single co C1: 15 x D

Flame C1tardant acc. to (IEC 60332-1)

 

Technical Specification

 

Conductor Type:

Class 1: rigidd conductor          Class 2, muliti-stranded conductor      

 

Cable Structure Data

Number of co C1s and size Insulation thickness Outer sheath thickness Outer diameter Weight of cable
mm2 mm mm D approx. mm approx. kg/km
1 x 16 C2 0,7 1,4 9,5 215
1 x 25 C2 0,9 1,4 11,0 310
1 x 35 C2 0,9 1,4 12,0 410
1 x 50 C2 1,0 1,4 13,5 540
1 x 70 C2 1,1 1,4 15,5 745
1 x 95 C2 1,1 1,5 17,5 1010
1 x 120 C2 1,2 1,5 19,0 1250
1 x 150 C2 1,4 1,6 21,0 1535
1 x 185 C2 1,6 1,6 23,5 1910
1 x 240 C2 1,7 1,7 26,0 2470
1 x 300 C2 1,8 1,8 28,5 3080
1 x 400 C2 2,0 1,9 32,0 3995
2 x 1,5 C1 0,7 1,8 10,5 145
2 x 2,5 C1 0,7 1,8 11,0 180
2 x 4 C1 0,7 1,8 12,0 225
2 x 6 C2 0,7 1,8 13,5 310
2 x 10 C2 0,7 1,8 15,0 420
2 x 16 C2 0,7 1,8 17,5 600
2 x 25 C2 0,9 1,8 20,5 880
2 x 35 C2 0,9 1,8 23,0 1160
3 x 1,5 C1 0,7 1,8 10,5 165
3 x 2,5 C1 0,7 1,8 11,5 210
3 x 4 C1 0,7 1,8 12,5 265
3 x 6 C2 0,7 1,8 14,5 370
3 x 10 C2 0,7 1,8 16,0 515
3 x 16 C2 0,7 1,8 18,5 750
3 x 25 C2 0,9 1,8 21,5 1110
3 x 35 C2 0,9 1,8 24,5 1475
3 x 50 C2 1,0 1,8 26,5 1865
3 x 70 C2 1,1 1,9 31,5 2680
3 x 95 C2 1,1 2,0 35,5 3600
3 x 120 C2 1,2 2,1 39,5 4515
3 x 150 C2 1,4 2,3 44,0 5555
3 x 185 C2 1,6 2,4 48,5 6930
3 x 240 C2 1,7 2,6 55,0 9010
3 x 300 C2 1,8 2,8 61,0 11195
4 x     1,5 C1 0,7 1,8 11,5 190
4 x 2,5 C1 0,7 1,8 12,5 245
4 x 4 C1 0,7 1,8 13,5 320
4 x 6 C2 0,7 1,8 15,5 445
4 x 10 C2 0,7 1,8 17,0 635
4 x 16 C2 0,7 1,8 20,0 930
4 x 25 C2 0,9 1,8 23,5 1390
4 x 35 C2 0,9 1,8 26,5 1850
4 x 50 C2 1,0 1,9 30,5 2450
4 x 70 C2 1,1 2,0 34,5 3410
4 x 95 C2 1,1 2,1 39,5 4640
4 x 120 C2 1,2 2,3 44,0 5780
4 x 150 C2 1,4 2,4 48,5 7075
4 x 185 C2 1,6 2,6 54,5 8965
4 x 240 C2 1,7 2,8 61,0 11510
4 x 300 C2 1,8 3,0 67,5 14370
5 x 1,5 C1 0,7 1,8 12,5 225
5 x 2,5 C1 0,7 1,8 13,5 290
5 x 4 C1 0,7 1,8 14,5 380
5 x 6 C2 0,7 1,8 17,0 540
5 x 10 C2 0,7 1,8 19,0 775
5 x 16 C2 0,7 1,8 21,5 1135
5 x 25 C2 0,9 1,8 27,0 1780
7 x 1,5 C1 0,7 1,8 13,5 275
7 x 2,5 C1 0,7 1,8 14,5 360
12 x 1,5 C1 0,7 1,8 17,0 450
12 x 2,5 C1 0,7 1,8 19,0 595
19 x 1,5 C1 0,7 1,8 20,0 615
19 x 2,5 C1 0,7 1,8 22,0 850
24 x 1,5 C1 0,7 1,8 23,0 785
24 x 2,5 C1 0,7 1,8 25,5 1050
27 x 1,5 C1 0,7 1,8 23,5 840
27 x 2,5 C1 0,7 1,8 26,0 1135
37 x 1,5 C1 0,7 1,8 26,0 1060
37 x 2,5 C1 0,7 1,8 29,0 1485

                    

        

     

 