4×120 + 1×70 mm2 N2xy, Power Cable, 0.6 1 Kv, Cu XLPE PVC
Place of use
These cables have a low dielectric loss, used in Indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
N2XY CU/XLPE/PVC – Construction
Conductor: | : rigid red copper wire, class 1 (Φ ≤ 4 mm²) stranded circular compacted copper class 2 (Φ>4mm²) |
Insulation | : XLPE crosslinked polyethylene (no dry cool) / PVC |
Filler | : Filler |
Outer sheath | : PVC / PE |
N2XY – Technical data and tests | |
Standards | : NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100 |
Nominal voltage U0/U | : 0,6/1 kV |
Test voltage (50 Hz) | : 4 kV |
Maximun voltage Um | : 1,2 kV |
Maximun operating temperature | : +90° C |
Maximun short circuit temperature | : +250° C |
Min. operating temperature (without mechanical shocks) |
: -25° C |
Minimum installation and use temp. | : -10° C |
Minimum bending radius per D cable diameter (in mm) |
: 8 x D |
Maximum pulling stress | : 5 kg/mm² (of copper cross section) |
Core colours | single core : black two cores : blue-Red three cores : red-yellow-blue four cores : red-yellow-blue-black five cores : red-yellow-blue-black-green Or as customer requirements |
Sheath colour | : black |
N2XY CU/XLPE/PVC– Applications
This cable is for use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required.
Presents good resistance to low temperatures and chemical agents. It can be used without additional mechanical protection in open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general.
It can be laid underground with mechanical protection constucted from slabs, tiles, or bricks. It is not recommended to lay this cable in ground flooded for more than two months per year.
With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%.
Power cable 0.6/1 kV – Other standards | |
German | : N2XY |
British | : CU/XLPE/PVC |
Serbian | : XP 00 |
Turkish | : YXV-U (-R) |
Romanian | : C2XY |
DIMENSIONS | |||||||||
Cores number N° |
Cross section mm² |
Approx conductor diameter mm |
Insulation medium thickness mm |
Min. sheath thickness mm |
Max. external diameter mm |
Electric resistance at 20°C ohm/km |
Approx cable weight kg/km |
Current carrying air free A |
Current carrying burried A |
Single core | |||||||||
1x | 1.5 | 1.4 | 0.7 | 1.09 | 6.6 | 12.1 | 45 | 24 | 31 |
1x | 2.5 | 1.8 | 0.7 | 1.09 | 7 | 7.41 | 55 | 33 | 41 |
1x | 4 | 2.25 | 0.7 | 1.09 | 7.6 | 4.61 | 75 | 45 | 59 |
1x | 6 | 3.05 | 0.7 | 1.09 | 8.2 | 3.08 | 100 | 58 | 74 |
1x | 10 | 3.8 | 0.7 | 1.09 | 9.2 | 1.83 | 140 | 80 | 101 |
1x | 16 | 4.7 | 0.7 | 1.09 | 10.5 | 1.15 | 205 | 107 | 128 |
1x | 25 | 5.9 | 0.9 | 1.09 | 12.5 | 0.727 | 315 | 138 | 144 |
1x | 35 | 7.1 | 0.9 | 1.09 | 13.5 | 0.524 | 400 | 169 | 174 |
1x | 50 | 8 | 1 | 1.09 | 15 | 0.387 | 530 | 207 | 206 |
1x | 70 | 9.6 | 1.1 | 1.09 | 17 | 0.268 | 725 | 268 | 254 |
1x | 95 | 11.4 | 1.1 | 1.18 | 19 | 0.193 | 985 | 328 | 301 |
1x | 120 | 13.1 | 1.2 | 1.18 | 21 | 0.153 | 1260 | 382 | 343 |
1x | 150 | 14.6 | 1.4 | 1.26 | 23 | 0.124 | 1520 | 441 | 387 |
1x | 185 | 16.5 | 1.6 | 1.26 | 25.5 | 0.0991 | 1940 | 506 | 434 |
1x | 240 | 18.4 | 1.7 | 1.35 | 28.5 | 0.0754 | 2310 | 599 | 501 |
1x | 300 | 21.1 | 1.8 | 1.43 | 31 | 0.0601 | 3200 | 693 | 565 |
1x | 400 | 23.5 | 2 | 1.52 | 34.2 | 0.047 | 3931 | – | 639 |
1x | 500 | 26.5 | 2.2 | 1.6 | 38 | 0.0366 | 5020 | – | 713 |
1x | 630 | 30.1 | 2.4 | 1.69 | 44 | 0.0286 | 5324 | – | 785 |
Two cores | |||||||||
2x | 1.5 | 1.4 | 0.7 | 1.43 | 10.5 | 12.1 | 115 | 26 | 37 |
2x | 2.5 | 1.8 | 0.7 | 1.43 | 11.5 | 7.41 | 145 | 36 | 48 |
2x | 4 | 2.25 | 0.7 | 1.43 | 13 | 4.61 | 195 | 49 | 63 |
2x | 6 | 3.05 | 0.7 | 1.43 | 14 | 3.08 | 265 | 63 | 80 |
2x | 10 | 3.8 | 0.7 | 1.43 | 16 | 1.83 | 390 | 86 | 104 |
2x | 16 | 4.7 | 0.7 | 1.43 | 18.5 | 1.15 | 560 | 115 | 136 |
2x | 25 | 5.9 | 0.9 | 1.43 | 22 | 0.727 | 850 | 149 | 173 |
2x | 35 | 7.1 | 0.9 | 1.43 | 24.5 | 0.524 | 1080 | 185 | 208 |
Three cores | |||||||||
3x | 1.5 | 1.4 | 0.7 | 1.43 | 11 | 12.1 | 130 | 23 | 31 |
3x | 2.5 | 1.8 | 0.7 | 1.43 | 12.5 | 7.41 | 170 | 31 | 41 |
3x | 4 | 2.25 | 0.7 | 1.43 | 13.5 | 4.61 | 230 | 42 | 53 |
3x | 6 | 3.05 | 0.7 | 1.43 | 15 | 3.08 | 325 | 54 | 66 |
3x | 10 | 3.8 | 0.7 | 1.43 | 17 | 1.83 | 485 | 75 | 87 |
3x | 16 | 4.7 | 0.7 | 1.43 | 19.5 | 1.15 | 705 | 100 | 113 |
3x | 25 | 5.9 | 0.9 | 1.43 | 23.5 | 0.727 | 1080 | 127 | 144 |
3x | 35 | 7.1 | 0.9 | 1.43 | 26 | 0.524 | 1390 | 158 | 174 |
3x | 50 | 8 | 1 | 1.43 | 29 | 0.387 | 1840 | 192 | 206 |
3x | 70 | 9.6 | 1.1 | 1.52 | 34 | 0.268 | 2540 | 246 | 254 |
3x | 95 | 11.4 | 1.1 | 1.6 | 38.5 | 0.193 | 3430 | 298 | 301 |
3x | 120 | 13.1 | 1.2 | 1.69 | 42.5 | 0.153 | 4440 | 346 | 343 |
3x | 150 | 14.6 | 1.4 | 1.86 | 47.5 | 0.124 | 5380 | 395 | 395 |
3x | 185 | 16.5 | 1.6 | 1.94 | 53 | 9.91 | 6920 | 450 | 434 |
3x | 240 | 18.4 | 1.7 | 2.11 | 59.5 | 7.54 | 8420 | 538 | 501 |
3x | 300 | 21.1 | 1.8 | 2.28 | 66 | 6.01 | 11300 | 621 | 565 |
DIMENSIONS | |||||||||
Cores number N° |
Cross section mm² |
Approx conductor diameter mm |
Insulation medium thickness mm |
Min. sheath thickness mm |
Max. external diameter mm |
Electric resistance at 20°C ohm/km |
Approx cable weight kg/km |
Current carrying air free A |
Current carrying burried A |
Four cores | |||||||||
4x | 1.5 | 1.4 | 0.7 | 1.43 | 12 | 12.1 | 150 | 23 | 31 |
4x | 2.5 | 1.8 | 0.7 | 1.43 | 13 | 7.41 | 205 | 31 | 41 |
4x | 4 | 2.25 | 0.7 | 1.43 | 14.5 | 4.61 | 280 | 42 | 53 |
4x | 6 | 3.05 | 0.7 | 1.43 | 16 | 3.08 | 390 | 54 | 66 |
4x | 10 | 3.8 | 0.7 | 1.43 | 18.5 | 1.83 | 590 | 75 | 87 |
4x | 16 | 4.7 | 0.7 | 1.43 | 21 | 1.15 | 870 | 100 | 113 |
4x | 25 | 5.9 | 0.9 | 1.43 | 25.5 | 0.727 | 1365 | 127 | 144 |
4x | 35 | 7.1 | 0.9 | 1.43 | 28.5 | 0.524 | 1760 | 158 | 174 |
4x | 50 | 8.1 | 1 | 1.52 | 32.5 | 0.387 | 2466 | 192 | 206 |
4x | 70 | 9.7 | 1.1 | 1.6 | 37.5 | 0.268 | 3442 | 246 | 254 |
4x | 95 | 11.4 | 1.1 | 1.69 | 42.5 | 0.193 | 4690 | 298 | 301 |
4x | 120 | 13.1 | 1.2 | 1.86 | 47.5 | 0.153 | 6119 | 346 | 343 |
4x | 150 | 14.6 | 1.4 | 1.94 | 52.5 | 0.124 | 7405 | 395 | 387 |
4x | 185 | 16.5 | 1.6 | 2.11 | 59 | 9.91 | 8820 | 450 | 434 |
4x | 240 | 18.5 | 1.7 | 2.28 | 66.5 | 7.54 | 11865 | 538 | 501 |
4x | 300 | 21 | 1.8 | 2.45 | 73.5 | 6.01 | 14716 | 621 | 565 |
3×50 + 1×35 | 8 | 1 | 1.52 | 31.1 | 0.387 | 2160 | 192 | 206 | |
3×70 + 1×50 | 9.6 | 1.1 | 1.6 | 36.2 | 0.268 | 3010 | 246 | 254 | |
3×95 + 1×50 | 11.4 | 1.1 | 1.69 | 40.6 | 0.193 | 3960 | 298 | 301 | |
3×120 + 1×70 | 13.1 | 1.2 | 1.86 | 45.4 | 0.153 | 5160 | 346 | 343 | |
3×150 + 1×70 | 14.6 | 1.4 | 1.94 | 49.5 | 0.124 | 6150 | 395 | 387 | |
3×185 + 1×70 | 16.5 | 1.6 | 2.11 | 54.4 | 9.91 | 7780 | 450 | 434 | |
3×240 + 1×95 | 18.4 | 1.7 | 2.28 | 61.5 | 7.54 | 9550 | 538 | 501 | |
Five cores | |||||||||
5x | 1.5 | 1.4 | 0.7 | 1.43 | 13 | 12.1 | 180 | 23 | 31 |
5x | 2.5 | 1.8 | 0.7 | 1.43 | 14.5 | 7.41 | 240 | 31 | 41 |
5x | 4 | 2.25 | 0.7 | 1.43 | 16 | 4.61 | 335 | 42 | 53 |
5x | 6 | 3.05 | 0.7 | 1.43 | 17.5 | 3.08 | 475 | 54 | 66 |
5x | 10 | 3.8 | 0.7 | 1.43 | 20 | 1.83 | 720 | 75 | 87 |
5x | 16 | 4.7 | 0.7 | 1.43 | 23 | 1.15 | 1060 | 100 | 113 |
5x | 25 | 5.9 | 0.9 | 1.43 | 28 | 0.727 | 1645 | 127 | 144 |
Multicores | |||||||||
7x | 1.5 | 1.4 | 0.7 | 1.43 | 13.5 | 12.1 | 220 | 15 | 22 |
7x | 2.5 | 1.8 | 0.7 | 1.43 | 15 | 7.41 | 310 | 20.5 | 28 |
10x | 1.5 | 1.4 | 0.7 | 1.43 | 16.5 | 12.1 | 310 | 13 | 18.5 |
10x | 2.5 | 1.8 | 0.7 | 1.43 | 19 | 7.41 | 440 | 18 | 24.5 |
12x | 1.5 | 1.4 | 0.7 | 1.43 | 17 | 12.1 | 370 | 12.5 | 18 |
12x | 2.5 | 1.8 | 0.7 | 1.43 | 19.5 | 7.41 | 525 | 17 | 24 |
14x | 1.5 | 1.4 | 0.7 | 1.43 | 18 | 12.1 | 430 | 12 | 17 |
14x | 2.5 | 1.8 | 0.7 | 1.43 | 20.5 | 7.41 | 610 | 16 | 22 |
19x | 1.5 | 1.4 | 0.7 | 1.43 | 19.5 | 12.1 | 560 | 10.5 | 15 |
19x | 2.5 | 1.8 | 0.7 | 1.43 | 22.5 | 7.41 | 745 | 14.5 | 19.5 |
24x | 1.5 | 1.4 | 0.7 | 1.43 | 22.5 | 12.1 | 710 | 10 | 14 |
24x | 2.5 | 1.8 | 0.7 | 1.43 | 25.5 | 7.41 | 1000 | 13 | 18 |
30x | 1.5 | 1.4 | 0.7 | 1.43 | 24 | 12.1 | 806 | 9 | 12.5 |
30x | 2.5 | 1.8 | 0.7 | 1.43 | 27.5 | 7.41 | 1135 | 12 | 16.5 |
37x | 1.5 | 1.4 | 0.7 | 1.43 | 25.5 | 12.1 | 972 | 8 | 12 |
37x | 2.5 | 1.8 | 0.7 | 1.43 | 29.5 | 7.41 | 1350 | 11 | 15.5 |
Packing
A: Reel of 1500 m.
B: Reel of 1000 m.
C: Reel of 500 m.
D: Multiple Reels of 1000 m.
E – Length to the client’s requirement.
Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping Port:
Shanghai, Qingdao, Tianjin or other ports as per your requirements.
Sea freight:
FOB/C&F/CIF/DAP quotation are all available.
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
We are looking forward to your inquiry and nice cooperation.
We are China 4X120 + 1X70 mm2 N2xy, Power Cable, 0.6/1 Kv, Cu/XLPE/PVC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: 0.6/1 Kv, Cu/ XLPE/ PVC, Henan Hongda Cable Co., Ltd., Power Cable, Power Cables