Power Cable Nyy 1X70mm2 Nyy-J Nyy-O Cable XLPE PVC Steel Wire Armroed Low Voltage Copper 0.6/1kv Yjv

Power Cable Nyy 1X70mm2 Nyy-J Nyy-O Cable XLPE PVC Steel Wire Armroed Low Voltage Copper 0.6/1kv Yjv image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
Our products are produced according to the standards of GB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA and so on. Meanwhile we can produce based on customers’ requirements and specifications. The company has passed ISO9001 2008 quality certification, CCC China Compulsory Certification, National Electrical Product Safety Certification, State Construction and ProjectCommitee Recommended Manufacturer of the Transformation of Urban and Rural Power Grid Construction.
Power Cable Nyy 1x70mm2 Nyy-j Nyy-o Cable Xlpe Pvc Steel Wire Armroed Low Voltage Copper 0.6/1kv Yjv
Item
|
Construction
|
Conductor
|
Annealed copper
|
Insulated
|
XLPE
|
Shielding
|
Semi-conductive tape
|
Metal shieding
|
Copper tape
|
Jacket
|
PVC
|
Rated voltage
|
8.7/15 KV
|
Conductor Size
|
3x120mm2
|
Color
|
Black
|
the range of distribution network, industrial equipments, high electricity consumption places etc.
Rated Voltage of cable U0/U(Um),as follow:
U0/U(Um)=8.7/15(17.5)kV.
2. The rated temperature of conductor
The maximum long-time working temperature of the cable conductor is 90ºC.
During having a short circuit, lasting less than 5 seconds, the maximum temperature of the cable conductor shall not be above 250ºC.
3. Ambient temperature for laying
The ambient temperature for laying shall be above 0ºC, otherwise the cable need be preheated.
4. The bend radius
The minimum bend radius of the cable see the table
Cross section area(mm²)
|
Insulated thickness(mm)
|
Metal shield thickness(mm)
|
Jacket thickness(mm)
|
OD(mm)
|
Weight(kg/km)
|
3×25
|
4.5
|
30×0.10
|
2.4
|
44.8
|
2251.6
|
3×35
|
4.5
|
40×0.10
|
2.5
|
47.2
|
2655.9
|
3×50
|
4.5
|
40×0.10
|
2.6
|
50.4
|
3217.3
|
3×70
|
4.5
|
40×0.10
|
2.7
|
54.0
|
3957.2
|
3×95
|
4.5
|
40×0.10
|
2.8
|
57.7
|
4884.7
|
3×120
|
4.5
|
40×0.10
|
2.9
|
60.9
|
5754.2
|
3×150
|
4.5
|
40×0.10
|
3.0
|
64.5
|
6788.0
|
3×185
|
4.5
|
40×0.10
|
3.1
|
68.2
|
7961.6
|
3×240
|
4.5
|
40×0.10
|
3.3
|
73.5
|
9801.3
|
3×300
|
4.5
|
40×0.10
|
3.4
|
78.3
|
11725.3
|
3×400
|
4.5
|
40×0.10
|
3.7
|
85.8
|
14799.2
|
Type |
Designation |
Applications |
YJV |
Copper conductor,XLPE insulated,PVC sheathed power cable |
For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. |
YJLV |
Aluminum conductor,XLPE insulated,PVC sheathed power cable |
|
YJY |
Copper conductor, XLPE insulated,PE sheathed power cable |
|
YJLY |
Aluminum conductor, XLPE insulated,PE sheathed power cable |
|
YJV22 |
Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable |
For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. |
YJLV22 |
Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable |
|
YJV23 |
Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable |
|
YJLV23 |
Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable |
|
YJV32 |
Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable |
For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. |
YJLV32 |
Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable |