Medium Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable

China Medium Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable  manufacture and supplier

Medium Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
YJV YJV22 N2XSY YJV32
Current
DC & AC
Insulation Material
XLPE
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS
Model
YJV
Brand
Shan Cable
Color
White/Black
MOQ
500m
Conductor
Copper
Insulation
XLPE
Sheath
PE
Armored
Aluminum Wire
Armored2
Steel Wire Armored
Armored 3
Steel Tape Armored
Transport Package
Wooden Steel Drum
Specification
2.0*2.0*1.35
Trademark
Shanghai Shenghua Cable Group
Origin
Shanghai, China
HS Code
8544492100
Production Capacity
100000

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 35.00cm
Package Gross Weight
30.000kg

Product Description

Medium Voltage Copper Conductor  XLPE Insulation PVC Sheath Power Cable

Product Description

6600 V 12/20KV N2XSY Cable N2XSYBY MV cable 185MM

Voltage:  6.35/11 26/35kV

1) Copper (aluminium) cores / XLPE insulated / PVC(PE) sheathed power cable

2) Copper (aluminium) cores /XLPE insulated /steel tape armored/ PVC ( PE) sheathed power cable

3) Copper (aluminium) cores /XLPE insulated / thin steel wire armored/ PVC ( PE) sheathed power cable

4) Copper (aluminium) cores /XLPE insulated / thick steel wire armored/ PVC ( PE) sheathed power cable

The products can be produced according to our factory specification which is equivalent to the standard IEC, ASTM, DIN. BS. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.

Remarks: Including products for flame retardant, fire resistant and termite-proof
Packing: Export wooden drums

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
 No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 2.5 0.1 1.2 0.2 1.9 37.9 1.87 2.32
3 X 35 6.9 2.5 0.1 1.3 0.5 2 41.5 2.1 2.73
3 X50 8.2 2.5 0.1 1.3 0.5 2 44.3 2.37 3.22
3 X 70 9.7 2.5 0.1 1.4 0.5 2.1 47.9 2.77 4
3 X 95 11.3 2.5 0.1 1.4 0.5 2.2 51.6 3.21 4.91
3 X 120 12.8 2.5 0.1 1.5 0.5 2.4 55.4 3.69 5.84
3 X 150 14.2 2.5 0.1 1.5 0.5 2.5 58.6 4.15 6.85
3 X 185 15.9 2.5 0.1 1.5 0.5 2.6 62.5 4.73 8.11
3 X 240 18.3 2.6 0.1 1.6 0.5 2.7 68.5 5.62 10.05
3 X 300 20.4 2.8 0.1 1.7 0.5 2.9 74.5 6.55 12.11
3 X 400 23.2 3 0.1 1.9 0.8 3.2 83.6 8.78 15.86
3 X 500 26.4 3.2 0.1 2.1 0.8 3.4 93 10.52 18.85
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 3.4 0.1 1.3 0.5 2 43.4 2.16 2.61
3 X 35 6.9 3.4 0.1 1.3 0.5 2 45.4 2.36 2.99
3 X50 8.2 3.4 0.1 1.4 0.5 2.2 48.8 2.69 3.54
3 X 70 9.7 3.4 0.1 1.5 0.5 2.3 52.4 3.1 4.33
3 X 95 11.3 3.4 0.1 1.5 0.5 2.4 56.1 3.56 5.26
3 X 120 12.8 3.4 0.1 1.5 0.5 2.5 59.5 4.04 6.19
3 X 150 14.2 3.4 0.1 1.5 0.5 2.6 62.7 4.49 7.19
3 X 185 15.9 3.4 0.1 1.6 0.5 2.6 66.6 5.12 8.49
3 X 240 18.3 3.4 0.1 1.7 0.5 2.8 72.4 5.99 10.42
3 X 300 20.4 3.4 0.1 1.8 0.5 3 77.5 6.86 12.42
3 X 400 23.2 3.4 0.1 1.9 0.8 3.2 85.4 8.97 16.05
3 X 500 26.4 3.4 0.1 2 0.8 3.4 93.7 10.65 19.5
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25 6 4.5 0.1 1.4 0.5 2.1 48.6 2.53 2.98
3 X 35 6.9 4.5 0.1 1.4 0.5 2.2 50.7 2.76 3.39
3 X50 8.2 4.5 0.1 1.5 0.5 2.3 53.9 3.1 3.95
3 X 70 9.7 4.5 0.1 1.5 0.5 2.4 57.4 3.51 4.74
3 X 95 11.3 4.5 0.1 1.5 0.5 2.6 61.2 4.05 5.75
3 X 120 12.8 4.5 0.1 1.6 0.5 2.6 64.7 4.56 6.72
3 X 150 14.2 4.5 0.1 1.6 0.5 2.7 67.9 5.04 7.74
3 X 185 15.9 4.5 0.1 1.7 0.5 2.8 71.9 5.66 9.04
3 X 240 18.3 4.5 0.1 1.8 0.5 3 77.7 6.56 11
3 X 300 20.4 4.5 0.1 1.9 0.8 3.2 84.1 8.39 13.96
3 X 400 23.2 4.5 0.1 2 0.8 3.3 90.5 9.71 16.79
3 X 500 26.4 4.5 0.1 2.1 0.8 3.5 98.8 11.45 20.57
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35 6.9 5.5 0.1 1.5 0.5 2.4 55.6 3.14 3.77
3 X50 8.2 5.5 0.1 1.5 0.5 2.5 58.6 3.49 4.34
3 X 70 9.7 5.5 0.1 1.5 0.5 2.6 62.1 3.93 5.16
3 X 95 11.3 5.5 0.1 1.6 0.5 2.6 65.7 4.46 6.16
3 X 120 12.8 5.5 0.1 1.7 0.5 2.7 69.4 5 7.15
3 X 150 14.2 5.5 0.1 1.7 0.5 2.8 72.6 5.49 8.19
3 X 185 15.9 5.5 0.1 1.8 0.5 3 76.9 6.16 9.53
3 X 240 18.3 5.5 0.1 1.9 0.8 3.2 83.9 7.87 12.31
3 X 300 20.4 5.5 0.1 2 0.8 3.2 88.6 8.96 14.52
3 X 400 23.2 5.5 0.1 2.1 0.8 3.5 95.4 10.35 17.43
3 X 500 26.4 5.5 0.1 2.2 0.8 3.7 103.7 12.45 20.23
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of Conductor  Nominal Diameter of Conductor  Nominal Thickness of Insulation  Nominal Thickness of Copper Tape Screen Nominal Thickness of Inner Sheath Nominal Thickness of Steel Tape Armouring Nominal Thickness of PVC Sheath Approx. Overall Diameter Approx. Weight
Al Conductor Cu Conductor 
No. X mm 2 mm mm mm mm mm mm mm kg/m kg/m
3 X 25                  
3 X 35                  
3 X50 8.2 8 0.1 1.7 0.5 2.8 70.4 4.56 5.41
3 X 70 9.7 8 0.1 1.7 0.5 2.9 73.9 5.04 6.26
3 X 95 11.3 8 0.1 1.8 0.5 3 77.7 5.62 7.32
3 X 120 12.8 8 0.1 1.9 0.8 3.2 82.8 6.99 9.15
3 X 150 14.2 8 0.1 1.9 0.8 3.2 85.8 7.56 10.26
3 X 185 15.9 8 0.1 2 0.8 3.3 89.9 8.3 11.67
3 X 240 18.3 8 0.1 2.1 0.8 3.5 95.7 9.36 13.79
3 X 300 20.4 8 0.1 2.2 0.8 3.6 100.6 10.51 16.07
3 X 400 23.2 8 0.1 2.3 0.8 3.8 107.2 11.99 19.07
3 X 500 26.4 8 0.1 2.4 0.8 4 120.1 14.15 23.85

Description:

CU/XLPE/LSOH, IEC 60331

IEC 60502, IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

CE, CCC, KEMA

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: LSOH

Sheath: LSOH , black

Note: Insulation color as per standards or customer requirement

Applications

Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.

Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 601034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request 

Technical data

Rated voltage: 0.6-KV

Max. Conductor Temp.: normal (90ºC), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250ºC )

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0ºC

Min. Bending Radius: single core cable 20(d+D)±5%

                    Multi-core cable 15(d+D)±5%

Product Name Medium Voltage Copper Conductor  XLPE Insulation PVC Sheath Power Cable
Model/Standard CU/XLPE/LSOH, IEC 60331, IEC 60502, IEC 60227, IEC 60331, IEC 601034, IEC 60754, GB/T 12706-91, GB306.1-2001, GB/T18380.3-2001, CE, CCC, KEMA
Conductor Material Circular stranded copper conductor, conforms to IEC 60228 class 2
Insulation Material XLPE/A
Inner Covering PVC/LSOH
Sheath Material PVC LSOH
Insulation Color As per standards or customer requirement
Rated Voltage 6.35/11kV to 26/35kV
Max. Conductor Temperature Normal: 90°C; Short circuit (5 seconds): Maximum conductor temperature not exceeding 250°C
Min. Ambient Temperature Cable should be preheated if ambient temperature is below 0°C
Min. Bending Radius Single-core cable: 20(d+D)±5%; Multi-core cable: 15(d+D)±5%

We are China Medium Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION