Model NO.
YJV32 YJLV32
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS
Model
Yjv32 Yjlv32
Brand
Qif
Core Number
1, 2, 3, 4, 3+1, 5, 4+1, 3+2
Nominal Cross Section of Conductor
1.5~800mm²
Other Types
Zryjv32, Nhyjv32
Warranty
100% Qualified
Armored Layer
Steel Wire
Packing Material
Wooden Drum
Insulation Color
Black, Red, Green, Orange
Transport Package
Standard Export Packing
Specification
1c, 2c, 3c, etc.
Trademark
QIF
Origin
China
HS Code
854449210
Production Capacity
500000m/Month

Product Description

Product Description

Structure
1.    Conductor – Plain annealed class 2 stranded (compacted) copper
2.    Insulation – Cross linked polyethylene (XLPE)
3.    Filler – Non-hygroscopic material
4.    Binder tape – Non-hygroscopic material tape
5.    Inner sheath – Polyvinyl chloride compound (PVC)
6.    Armor – Galvanized steel wires
7.    Binder tape – Non-hygroscopic material tape
8.    Outer sheath – Polyvinyl chloride compound (PVC)

Application
To be used for main power supply such as in low voltage distribution power networks, indoor and outdoor areas. It can be installed in ducts, in dry or wet locations, recommended for direct burial where require higher electrical and mechanical protection.

Temperature characteristics                 
Conductor operating temperature: -15ºC~90ºC                  
Min. temperatrue laying condition: 0ºC                 
Conductor emergency operating temperature: 105ºC
Conductor short-circuit operating temperature (5s): 250ºC
 
Electrical Characteristics
Rated voltage: 0.6/1 (1.2) kV
High voltage test: 3.5kV / 5min
 
Color
Insulation: According to customer requirements
Outer sheath: Black or according to customer requirements
 
Standard
Cable design: IEC 60502-1 or AS/ZNS 5000.1
Conductor: IEC 60228 or AS/ZNS 1125

Detailed Photos

 

Product Parameters

Nom. Cross-Sectional Area of Conductor mm2 Insulation Thickness mm Inner Sheath Thickness mm Steel Wire Diameter mm Outer Sheath Thickness mm Overall Diameter mm Approx. Weight kg/km Max. D.C. Resistance of Conductor@20°C /km
2×1.5 0.7 1.0 0.9 1.8 15.0 330 12.1
2×2.5 0.7 1.0 0.9 1.8 16.0 376 7.41
2×4 0.7 1.0 0.9 1.8 17.0 554 4.61
2×6 0.7 1.0 0.9 1.8 18.2 633 3.08
2×10 0.7 1.0 1.3 1.8 21.0 797 1.83
2×16 0.7 1.0 1.6 1.8 23.5 1124 1.15
2×25 0.9 1.0 1.6 1.8 26.0 1417 0.727
2×35 0.9 1.0 1.6 1.8 30.5 1694 0.524
2×50 1.0 1.0 1.6 1.8 27.0 1787 0.387
2×70 1.1 1.0 1.6 2.0 30.0 2181 0.268
2×95 1.1 1.2 1.6 2.1 34.0 2768 0.193
2×120 1.2 1.2 2.0 2.2 36.5 3500 0.153
2×150 1.4 1.2 2.0 2.4 42.0 4233 0.124
2×185 1.6 1.2 2.0 2.5 45.0 4979 0.0991
2×240 1.7 1.4 2.5 2.8 61.0 8623 0.0754
2×300 1.8 1.5 2.5 2.9 66.0 10229 0.0601
2×400 2.0 1.7 2.5 3.2 73.8 12641 0.047

Nom. Cross-Sectional Area of Conductor mm2 Insulation Thickness mm Inner Sheath Thickness mm Steel Wire Diameter mm Outer Sheath Thickness mm Overall Diameter mm Approx. Weight kg/km Max. D.C. Resistance of Conductor@20°C Ω/km
3×1.5 0.7 1.0 0.9 1.8 15.8 359 12.1
3×2.5 0.7 1.0 0.9 1.8 16.8 378 7.41
3×4 0.7 1.0 0.9 1.8 18.0 454 4.61
3×6 0.7 1.0 0.9 1.8 19.0 545 3.08
3×10 0.7 1.0 1.3 1.8 22.0 721 1.83
3×16 0.7 1.0 1.6 1.8 24.5 951 1.15
3×25 0.9 1.0 1.6 1.8 29.2 1655 0.727
3×35 0.9 1.0 1.6 1.8 32.5 2033 0.524
3×50 1.0 1.0 1.6 1.9 33.0 2577 0.387
3×70 1.1 1.0 1.6 2.0 37.0 3688 0.268
3×95 1.1 1.2 1.6 2.1 43.0 4641 0.193
3×120 1.2 1.2 2.0 2.3 45.0 5561 0.153
3×150 1.4 1.4 2.0 2.4 51.0 7172 0.124
3×185 1.6 1.4 2.0 2.6 56.0 8619 0.0991
3×240 1.7 1.4 2.5 2.8 62.0 10711 0.0754
3×300 1.8 1.6 2.5 3.0 67.0 12862 0.0601
3×400 2.0 1.6 2.5 3.2 76.0 16879 0.047

Nom. Cross-Sectional Area of Conductor mm2 Insulation Thickness mm Inner Sheath Thickness mm Steel Wire Diameter mm Outer Sheath Thickness mm Overall Diameter mm Approx. Weight kg/km Max. D.C. Resistance of Conductor@20°C Ω/km
4×4 0.7 1.0 0.9 1.8 18.0 522 4.61
4×6 0.7 1.0 1.3 1.8 19.0 638 3.08
4×10 0.7 1.0 1.3 1.8 22.0 859 1.83
4×16 0.7 1.0 1.6 1.8 24.5 1458 1.15
4×25 0.9 1.0 1.6 1.8 29.2 1989 0.727
4×35 0.9 1.0 2.0 1.9 32.5 2487 0.524
4×50 1.0 1.0 2.0 2.0 33.0 3407 0.387
4×70 1.1 1.0 2.0 2.1 37.0 4533 0.268
4×95 1.1 1.2 2.0 2.3 43.0 5768 0.193
4×120 1.2 1.2 2.5 2.4 45.0 7438 0.153
4×150 1.4 1.4 2.5 2.5 51.0 8884 0.124
4×185 1.6 1.4 2.5 2.7 56.0 10794 0.0991
4×240 1.7 1.4 2.5 3.0 62.0 13437 0.0754
4×300 1.8 1.6 2.5 3.2 67.0 16224 0.0601
4×400 2.0 1.6 3.2 3.5 74.0 21291 0.047
3×4+1×2.5 0.7 1.0 0.9 1.8 18.7 624 4.61
3×6+1×4 0.7 1.0 0.9 1.8 20.0 752 3.08
3×10+1×6 0.7 1.0 1.3 1.8 23.3 1154 1.83
3×16+1×10 0.7 1.0 1.3 1.8 25.8 1456 1.15
3×25+1×16 0.9 1.0 1.6 1.8 30.0 1905 0.727
3×35+1×16 0.9 1.0 1.6 1.8 33.0 2259 0.524
3×50+1×25 1.0 1.0 1.6 1.9 35.5 2705 0.387
3×70+1×35 1.1 1.2 2.0 2.0 41.0 3729 0.268
3×95+1×50 1.1 1.2 2.0 2.1 46.0 4732 0.193
3×120+1×70 1.2 1.4 2.0 2.3 51.0 6071 0.153
3×150+1×70 1.4 1.4 2.5 2.4 56.5 7198 0.124
3×185+1×95 1.6 1.4 2.5 2.6 62.0 8558 0.0991
3×240+1×120 1.7 1.6 2.5 2.8 68.0 10580 0.0754
3×300+1×150 1.8 1.6 2.5 3.0 75.0 12742 0.0601

Nom. Cross-Sectional Area of Conductor mm2 Insulation Thickness mm Inner Sheath Thickness mm Steel Wire Diameter mm Outer Sheath Thickness mm Overall Diameter mm Approx. Weight kg/km Max. D.C. Resistance of Conductor@20°C Ω/km
5×4 0.7 1.0 1.3 1.8 17.4 597 4.61
5×6 0.7 1.0 1.3 1.8 18.7 734 3.08
5×10 0.7 1.0 1.6 1.8 23.0 1292 1.83
5×16 0.7 1.0 1.6 1.8 25.7 1688 1.15
5×25 0.9 1.0 1.6 1.8 30.2 2343 0.727
5×35 0.9 1.0 1.6 1.9 33.1 2941 0.524
5×50 1.0 1.2 2.0 2.1 38.5 4095 0.387
5×70 1.1 1.2 2.0 2.3 44.2 5407 0.268
5×95 1.1 1.4 2.5 2.5 50.3 7413 0.193
5×120 1.2 1.4 2.5 2.6 54.9 8904 0.153
5×150 1.4 1.4 2.5 2.8 60.8 10784 0.124
5×185 1.6 1.6 2.5 3.0 66.9 13030 0.0991
5×240 1.7 1.6 3.2 3.3 74.1 16291 0.0754
5×300 1.8 1.8 3.2 3.6 86.8 21197 0.0601
5×400 2.0 2.0 3.2 3.9 96.7 26275 0.047
3×4+2×2.5 0.7 1.0 0.9 3.2 18.7 735 4.61
3×6+2×4 0.7 1.0 1.3 1.8 21.0 879 3.08
3×10+2×6 0.7 1.0 1.3 1.8 24.2 1263 1.83
3×16+2×10 0.7 1.0 1.6 1.8 27.5 1616 1.15
3×25+2×16 0.9 1.0 1.6 1.8 32.5 2142 0.727
3×35+2×16 0.9 1.0 1.6 1.8 35.5 2492 0.524
3×50+2×25 1.0 1.0 2.0 1.9 40.0 3408 0.387
3×70+2×35 1.1 1.0 2.0 2.2 45.6 4338 0.268
3×95+2×50 1.1 1.2 2.0 2.4 50.0 5374 0.193
3×120+2×70 1.2 1.2 2.5 2.6 56.9 7145 0.153
3×150+2×70 1.4 1.4 2.5 2.7 62.4 8076 0.124
3×185+2×95 1.6 1.4 2.5 3.0 67.6 9779 0.0991
3×240+2×120 1.7 1.4 2.5 3.2 73.8 12024 0.0754
3×300+2×150 1.8 1.6 3.2 3.4 83.0 14366 0.0601
4×4+1×2.5 0.7 1.0 0.9 1.8 20.0 752 4.61
4×6+1×4 0.7 1.0 1.3 1.8 21.5 913 3.08
4×10+1×6 0.7 1.0 1.3 1.8 25.0 1323 1.83
4×16+1×10 0.7 1.0 1.6 1.8 28.6 1691 1.15
4×25+1×16 0.9 1.0 1.6 1.8 33.5 2256 0.727
4×35+1×16 0.9 1.0 1.6 1.9 36.0 2957 0.524
4×50+1×25 1.0 1.0 2.0 2.2 42.0 3643 0.387
4×70+1×35 1.1 1.2 2.0 2.4 47.0 4614 0.268
4×95+1×50 1.1 1.2 2.0 2.6 51.2 6140 0.193
4×120+1×70 1.2 1.4 2.5 2.8 59.0 7544 0.153
4×150+1×70 1.4 1.4 2.5 3.0 64.0 8733 0.124
4×185+1×95 1.6 1.4 2.5 3.1 71.0 10597 0.0991
4×240+1×120 1.7 1.6 2.5 3.3 78.0 13029 0.0754
4×300+1×150 1.8 1.6 3.2 3.5 88.0 17172 0.0601
*The information in this datasheet is for reference only and is subject to change without notice or liability.

Related Type

Type Description No. of cores Nominal Cross
Section of Conductor
YJV32 Copper conductor XLPE insulation Steel Wire Armoured PVC outer sheath Power Cable 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 1.5~800mm²
YJV33 Copper conductor XLPE insulation Steel Wire Armoured PE outer sheath Power Cable 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 1.5~800mm²
ZA-YJV32
ZB-YJV32
ZC-YJV32
Copper conductor XLPE insulation Steel Wire Armoured flame-retardant Power Cable 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 1.5~800mm²
WDZA-YJY33
WDZB-YJY33
WDZC-YJY33
Copper conductor XLPE insulation Steel Wire Armoured Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 1.5~800mm²
NH-YJV32 Copper conductor XLPE insulation Steel Wire Armoured fire-resistant Power Cable 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 1.5~800mm²

 

Workshop

 

Test Equipment

Packaging & Shipping

 

FAQ

How can I get some samples?

We provide free sample and will courier to you by DHL, FEDEX, UPS, TNT, etc. swiftly according to your requirements.

How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.   
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..

What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.

What’s the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement

What’s the lead time?
Usually 10-30 working days.

Welcome your inquiry and email soon……

We are China Wholesale Good Quality Cu/Al//XLPE/Swa/PVC Copper Aluminium Conductor Steel Wire Armoured Low Voltage Yjv32 Yjlv32 Electrical Wire Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION