600V UL Listed Solid Copper12awgmetal Clad Cables Bx AC Cable

China 600V UL Listed Solid Copper12awgmetal Clad Cables Bx AC Cable  manufacture and supplier

600V UL Listed Solid Copper12awgmetal Clad Cables Bx AC Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
AC BX
Application
Underground
Conductor Material
Copper or Aluminum
Sheath Material
PVC
Insulation Material
PVC
Material Shape
Round Wire
Range of Application
Commercial, Industrial
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Huatong
Voltage
Low Voltage 600V, 2000V
Armored Material
Aluminum/Steel Interlock
Transport Package
Coils and Drums
Specification
12AWG to 2000KCMIL
Trademark
Renda
Origin
China
HS Code
8544492100
Production Capacity
200000m/Month

Product Description

 
 

 
APPLICATION

Type MC Cable – Isolated Ground is constructed with soft-drawn copper, Type THHN/THWN

conductors rated 90°C dry available in sizes 12 AWG and 10 AWG, and two insulated grounding conductors–one solid green and the second green with yellow stripes. The conductors are cabled together and a binder tape bearing the print legend is

wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. 

Type AC Cable BX is constructed with soft-drawn copper, Type THHN insulated conductors which are

individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.

 

Power Tray Cable Applications
  • Type MC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
    • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
 
  • Type AC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Dry locations only.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).

STANDARDS & REFERENCES

Type AC Cable meet or exceeds the following requirements

• UL 4, 83, 1581, 2556

• Federal Specification A-A59544 (formerly J-C-30B)

• National Electrical Code Article 320 Armored Cable: Type AC

Type MC Cable meets or exceeds the requirements of the following

• UL 83

• UL 1569

• UL 1685

• Federal Specification A-A59544 (formerly J-C-30B)

• FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test

• NEC

• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

CONSTRUCTION

Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry

available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.

Type AC Cable is constructed with soft-drawn copper, Type THHN insulated conductors which are

individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.

.

Conductor Size  Solid or Stranded  Grounding Conductor Size  Overall Diameter Weight  Ampacity (Amps)
 (AWG)   (AWG)  (inches)  (lbs./1000ft.)  60 75 90
14-2 Solid  14 0.439 77 15 15 15
14-3 Solid  14 0.464 94 15 15 15
14-4 Solid  14 0.494 112 15 15 15
12-2 Solid  12 0.527 137 20 20 20
12-3 Solid  12 0.505 129 20 20 20
12-4 Solid  12 0.539 155 20 20 20
10-2 Solid  10 0.542 150 30 30 30
10-3 Solid  10 0.58 189 30 30 30
10-4 Solid  10 0.623 229 30 30 30

 

 

We are China 600V UL Listed Solid Copper12awgmetal Clad Cables Bx AC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.