IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core)

IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core) image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
IEC 60502 Type Cable
0.6/1 kV CVV-SWA
IEC 60502 (2-30 core)
Application : For use in duct, tray and for direct burying in ground. The cable subject to immerce in water all the
line.
Conductor : Concentric Stranded annealed copper wire
Insulation : PVC Black color
Identification : Printed White number on the surface of Black insulation
Filler : Suitable filler
Binding tape : Suitable tape
Inner sheath : PVC Black color
Armour : Galvanized steel wire
Binding tape : Suitable tape
Outher Sheath : PVC Black color
2 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thickn ess of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
2 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 36.0 | 0.0162 | 320 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 24.5 | 0.0142 | 345 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 16.0 | 18.1 | 0.0135 | 350 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 12.1 | 0.0115 | 390 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 0.80 | 1.8 | 17.5 | 7.41 | 0.0093 | 460 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 21.0 | 4.61 | 0.0092 | 710 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 22.0 | 3.08 | 0.0078 | 820 | 500/D |
3 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 36.0 | 0.0162 | 365 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 16.0 | 24.5 | 0.0142 | 370 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 18.1 | 0.0135 | 385 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 12.1 | 0.0115 | 430 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 7.41 | 0.0093 | 635 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 21.5 | 4.61 | 0.0092 | 800 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 23.0 | 3.08 | 0.0078 | 935 | 500/D |
4 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm | No.&dia.of wires No./mm | Thickness of insulation mm | Thickness of inner sheath mm | Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at 20C) Ohm/km |
Minimum insulation resistance (at 70C) Ohm/km |
Cable weight (Approx.) kg/km |
Stan dard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 36.0 | 0.0162 | 380 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 24.5 | 0.0142 | 410 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 18.1 | 0.0135 | 425 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 12.1 | 0.0115 | 480 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 7.41 | 0.0093 | 715 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 23.0 | 4.61 | 0.0092 | 915 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 24.5 | 3.08 | 0.0078 | 1075 | 500/D |
5 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 36.0 | 0.0162 | 420 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 24.5 | 0.0142 | 455 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 19.0 | 18.1 | 0.0135 | 595 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 12.1 | 0.0115 | 665 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 21.5 | 7.41 | 0.0093 | 805 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 24.5 | 4.61 | 0.0092 | 1040 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 27.0 | 3.08 | 0.0078 | 1385 | 500/D |
6 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thic kness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 36.0 | 0.0162 | 450 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 18.1 | 0.0135 | 635 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 12.1 | 0.0115 | 715 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 7.41 | 0.0093 | 870 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 26.5 | 4.61 | 0.0092 | 1270 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 28.5 | 3.08 | 0.0078 | 1515 | 500/D |
7 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thickn ess of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 36.0 | 0.0162 | 455 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 24.5 | 0.0142 | 620 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 18.1 | 0.0135 | 650 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 12.1 | 0.0115 | 730 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 7.41 | 0.0093 | 895 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 26.5 | 4.61 | 0.0092 | 1315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 28.5 | 3.08 | 0.0078 | 1580 | 500/D |
Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 36.0 | 0.0162 | 625 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 24.5 | 0.0142 | 680 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 18.1 | 0.0135 | 710 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 12.1 | 0.0115 | 810 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 7.41 | 0.0093 | 995 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 28.0 | 4.61 | 0.0092 | 1470 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 30.0 | 3.08 | 0.0078 | 1770 | 500/D |
9 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 36.0 | 0.0162 | 680 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 21.5 | 24.5 | 0.0142 | 750 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 18.1 | 0.0135 | 770 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 12.1 | 0.0115 | 885 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 26.0 | 7.41 | 0.0093 | 1230 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 29.5 | 4.61 | 0.0092 | 1630 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.9 | 32.0 | 3.08 | 0.0078 | 1975 | 500/D |
10 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 725 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 24.5 | 0.0142 | 800 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 18.1 | 0.0135 | 835 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 12.1 | 0.0115 | 955 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 7.41 | 0.0093 | 1385 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.0 | 4.61 | 0.0092 | 1775 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 24.5 | 3.08 | 0.0078 | 2170 | 500/D |
11 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
11 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 765 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 24.5 | 0.0142 | 840 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 18.1 | 0.0135 | 880 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 12.1 | 0.0115 | 1150 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 28.0 | 7.41 | 0.0093 | 1415 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.5 | 4.61 | 0.0092 | 1905 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 3.08 | 0.0078 | 2310 | 500/D |
12 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
12 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 765 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 24.5 | 0.0142 | 845 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 18.1 | 0.0135 | 885 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 12.1 | 0.0115 | 1160 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 28.0 | 7.41 | 0.0093 | 1435 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.5 | 4.61 | 0.0092 | 1940 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 3.08 | 0.0078 | 2365 | 500/D |
13 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
13 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 36.0 | 0.0162 | 820 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 24.5 | 0.0142 | 905 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 18.1 | 0.0135 | 950 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 12.1 | 0.0115 | 1230 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 29.0 | 7.41 | 0.0093 | 1545 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 34.0 | 4.61 | 0.0092 | 2085 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.1 | 38.0 | 3.08 | 0.0078 | 2820 | 500/D |
14 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thic kness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
14 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 36.0 | 0.0162 | 825 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 24.5 | 0.0142 | 915 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 18.1 | 0.0135 | 955 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 12.1 | 0.0115 | 1240 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 29.0 | 7.41 | 0.0093 | 1565 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 34.0 | 4.61 | 0.0092 | 2120 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.1 | 38.0 | 3.08 | 0.0078 | 2570 | 500/D |
15 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
15 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 36.0 | 0.0162 | 880 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 24.5 | 0.0142 | 1115 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.60 | 1.8 | 26.0 | 18.1 | 0.0135 | 1150 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 12.1 | 0.0115 | 1330 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 30.0 | 7.41 | 0.0093 | 1675 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 4.61 | 0.0092 | 2305 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 2.00 | 2.1 | 39.5 | 3.08 | 0.0078 | 3085 | 500/D |
16 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm | No.&dia.of wires No./mm | Thickness of insulation mm | Thickness of inner sheath mm | Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at 20C) Ohm/km |
Minimum insulation resistance (at 70C) Ohm/km |
Cable weight (Approx.) kg/km |
Stan dard Length m |
16 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 36.0 | 0.0162 | 885 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 24.5 | 0.0142 | 1225 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 18.1 | 0.0135 | 1160 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 12.1 | 0.0115 | 1345 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 30.0 | 7.41 | 0.0093 | 1700 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 4.61 | 0.0092 | 2340 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 2.00 | 2.1 | 39.5 | 3.08 | 0.0078 | 3135 | 500/D |
The table of 0.6/1 KV CVV-SWA shown concentric stranded conductor only
If you want to have solid or flexible conductor type, please contact with our Sales Department.
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: 2464 Control Cable, 4mm2 Control Cable, HENAN BAOFENG CABLE CO., Ltd.