IEC60502 Copper Conductor PVC Sheath Underground Cable

China IEC60502 Copper Conductor PVC Sheath Underground Cable  manufacture and supplier

IEC60502 Copper Conductor PVC Sheath Underground Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
underground cable
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, RoHS, VDE, Ma
Model
Myp
Brand
Qifan
Code
8544492900
Cable Voltage
Low & Medium Voltage
Cable Test
3.0/5 Min
Cable Length
as Requirement
Delivery Time
3-50 Days
Transport Package
Drums
Specification
4-150mm
Trademark
Qifan
Origin
China
HS Code
8544492900
Production Capacity
100000000km

Packaging & Delivery

Package Size
1100.00cm * 300.00cm * 1100.00cm
Package Gross Weight
1000.000kg

Product Description

Product Description

 

IEC60502 COPPER CONDUCTOR PVC SHEATH underground cable

Cable Mode
VV-0.6/1kV

Application scope
This product is suitable for use in AC 50Hz circuits with a rated voltage of not more than 0.6/1kV, for the purpose of power transmission and distribution.

Cable Structure
Conductor
Class 1 or Class 2 copper conductor

Insulation
(PVC)

Filling (optional)
Polypropylene mesh  rope

Sheath
(PVC)

Standard
GB/T 12706.1,IEC 60502-1

Mode Scope
1 Core :1.5~1000mm2
2 Core :1.5~400mm2
3 Core :1.5~400mm2
4Core:1.5~400mm2
5Core:1.5~400mm2
3+1Core:2.5~400mm2
3+2Core:2.5~400mm2
4+1Core:2.5~400mm2

 Core Identification

2 Core :Red Blue
3 Core:Yellow Green Red  Red BlueYellow /Green
4 Core:Yellow Green Red Blue
5 Core:Yellow Green Red blued Yellow/Green

Colour of Sheath
Black
 

Technical parameters
Rated voltage (U0/U)
0.6/1kV
Maximum system voltage (Um):
1.2kV

Temperature rating
Conductor maximum operating temperature: +70ºC
Ambient temperature for usage: -20ºC~+45ºC
Cable laying temperature: Not lower than 0ºC (When the ambient temperature is below 0ºC, the cable should be preheated)

Minimum bending radius:
Single-core cable: 20D
Multi-core cable: 15D
Note: D stands for the actual outer diameter of the cable

Installation methods:
Conduit laying, shallow groove laying, cable trench laying, tunnel laying, sandwich laying, support-type overhead laying, suspension-type overhead laying, etc.

Product Parameters

 

 

VV-0.6/1kVCable Structure Data Table 1  
Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
1×1.5 1.38 0.8 1.4 5.9 50
1×2.5 1.78 0.8 1.4 6.3 63
1×4 2.25 1.0 1.4 7.2 87
1×6 2.76 1.0 1.4 7.7 111
1×10 4.0 1.0 1.4 8.9 158
1×16 5.0 1.0 1.4 9.9 221
1×25 6.1 1.2 1.4 11.4 324
1×35 7.2 1.2 1.4 12.5 421
1×50 8.4 1.4 1.4 14.1 554
1×70 10.0 1.4 1.5 15.9 767
1×95 12.0 1.6 1.5 18.4 1042
1×120 13.0 1.6 1.6 19.6 1281
1×150 14.9 1.8 1.6 21.9 1575
1×185 16.5 2.0 1.7 24.1 1949
1×240 18.4 2.2 1.8 26.6 2529
1×300 21.0 2.4 1.9 29.8 3154
1×400 23.4 2.6 2.0 32.9 4010
1×500 26.6 2.8 2.1 36.7 5097
1×630 30.0 2.8 2.2 40.3 6429
1×800 34.0 2.8 2.3 44.5 8118
1×1000 38.2 3.0 2.5 49.5 10145

VV-0.6/1kVCable Structure Data Table 2

Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
2×1.5 1.38 0.8 1.8 10.4 123
2×2.5 1.78 0.8 1.8 11.2 152
2×4 2.25 1.0 1.8 13.0 212
2×6 2.76 1.0 1.8 14.0 264
2×10 4.0 1.0 1.8 16.4 373
2×16 5.0 1.0 1.8 18.4 515
2×25 6.1 1.2 1.8 21.4 746
2×35 7.2 1.2 1.8 23.6 963
2×50 8.4 1.4 1.8 27.1 1275
2×70 10.0 1.4 1.9 30.5 1739
2×95 12.0 1.6 2.0 35.5 2374
2×120 13.0 1.6 2.1 37.7 2885
2×150 14.9 1.8 2.2 42.6 3577
2×185 16.5 2.0 2.4 47.0 4424
2×240 18.4 2.2 2.6 52.0 5708
2×300 21.0 2.4 2.7 58.3 7112
2×400 23.4 2.6 3.0 64.5 9035

VV-0.6/1kVCable Structure Data Table3

Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
3×1.5 1.38 0.8 1.8 10.9 148
3×2.5 1.78 0.8 1.8 11.7 187
3×4 2.25 1.0 1.8 13.7 267
3×6 2.76 1.0 1.8 14.7 338
3×10 4.0 1.0 1.8 17.4 488
3×16 5.0 1.0 1.8 19.5 685
3×25 6.1 1.2 1.8 22.8 1011
3×35 7.2 1.2 1.8 25.4 1326
3×50 8.4 1.4 1.8 28.9 1750
3×70 10.0 1.4 2.0 32.8 2425
3×95 12.0 1.6 2.1 38.2 3319
3×120 13.0 1.6 2.2 40.5 4053
3×150 14.9 1.8 2.3 45.7 5017
3×185 16.5 2.0 2.5 50.5 6216
3×240 18.4 2.2 2.7 55.9 8051
3×300 21.0 2.4 2.9 62.8 10060
3×400 23.4 2.6 3.1 69.3 12775

VV-0.6/1kVCable Structure Data Table Table 4

Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
4×1.5 1.38 0.8 1.8 11.7 177
4×2.5 1.78 0.8 1.8 12.6 228
4×4 2.25 1.0 1.8 14.8 329
4×6 2.76 1.0 1.8 16.0 423
4×10 4.0 1.0 1.8 19.0 616
4×16 5.0 1.0 1.8 21.4 874
4×25 6.1 1.2 1.8 25.3 1306
4×35 7.2 1.2 1.8 27.9 1707
4×50 8.4 1.4 1.9 32.0 2276
4×70 10.0 1.4 2.1 36.3 3158
4×95 12.0 1.6 2.2 42.4 4330
4×120 13.0 1.6 2.4 45.2 5319
4×150 14.9 1.8 2.5 51.0 6582
4×185 16.5 2.0 2.7 56.3 8152
4×240 18.4 2.2 2.9 62.3 10566
4×300 21.0 2.4 3.1 70.0 13201
4×400 23.4 2.6 3.4 77.4 16806


VV-0.6/1kVCable Structure Data Table Table 5
Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
5×1.5 1.38 0.8 1.8 12.5 207
5×2.5 1.78 0.8 1.8 13.6 271
5×4 2.25 1.0 1.8 16.0 394
5×6 2.76 1.0 1.8 17.4 512
5×10 4.0 1.0 1.8 20.7 748
5×16 5.0 1.0 1.8 23.4 1068
5×25 6.1 1.2 1.8 27.7 1602
5×35 7.2 1.2 1.9 30.8 2114
5×50 8.4 1.4 2.1 35.6 2837
5×70 10.0 1.4 2.2 40.1 3914
5×95 12.0 1.6 2.4 47.1 5392
5×120 13.0 1.6 2.5 50.0 6600
5×150 14.9 1.8 2.7 56.6 8192
5×185 16.5 2.0 2.9 62.5 10146
5×240 18.4 2.2 3.1 69.2 13153
5×300 21.0 2.4 3.3 77.7 16428
5×400 23.4 2.6 3.7 86.1 20951

VV-0.6/1kVCable Structure Data Table Table 6

Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
3×2.5+1×1.5 1.78/1.38 0.8/0.8 1.8 12.4 216
3×4+1×2.5 2.25/1.78 1.0/0.8 1.8 14.2 302
3×6+1×4 2.76/2.25 1.0/1.0 1.8 15.6 398
3×10+1×6 4.0/2.76 1.0/1.0 1.8 18.1 564
3×16+1×10 5.0/4.0 1.0/1.0 1.8 20.7 807
3×25+1×16 6.1/5.0 1.2/1.0 1.8 24.0 1187
3×35+1×16 7.2/5.0 1.2/1.0 1.8 26.3 1497
3×50+1×25 8.4/6.1 1.4/1.2 1.9 30.4 2034
3×70+1×35 10.0/7.2 1.4/1.2 2.0 34.2 2786
3×95+1×50 12.0/8.4 1.6/1.4 2.2 39.9 3818
3×120+1×70 13.0/10.0 1.6/1.4 2.3 42.8 4762
3×150+1×70 14.9/10.0 1.8/1.4 2.4 47.6 5719
3×185+1×95 16.5/12.0 2.0/1.6 2.6 53.0 7191
3×240+1×120 18.4/13.5 2.2/1.6 2.8 58.4 9249
3×300+1×150 21.0/14.9 2.4/1.8 3.0 65.6 11543
3×400+1×185 23.4/16.5 2.6/2.0 3.2 72.4 14615

VV-0.6/1kVCable Structure Data Table Table 7

Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
3×2.5+2×1.5 1.78/1.38 0.8/0.8 1.8 13.2 246
3×4+2×2.5 2.25/1.78 1.0/0.8 1.8 15.2 347
3×6+2×4 2.76/2.25 1.0/1.0 1.8 16.9 465
3×10+2×6 4.0/2.76 1.0/1.0 1.8 19.5 654
3×16+2×10 5.0/4.0 1.0/1.0 1.8 22.4 941
3×25+2×16 6.1/5.0 1.2/1.0 1.8 26.2 1393
3×35+2×16 7.2/5.0 1.2/1.0 1.8 28.2 1696
3×50+2×25 8.4/6.1 1.4/1.2 1.9 32.6 2334
3×70+2×35 10.0/7.2 1.4/1.2 2.1 36.9 3204
3×95+2×50 12.0/8.4 1.6/1.4 2.2 42.9 4363
3×120+2×70 13.0/10.0 1.6/1.4 2.4 46.4 5532
3×150+2×70 14.9/10.0 1.8/1.4 2.5 50.9 6492
3×185+2×95 16.5/12.0 2.0/1.6 2.7 57.0 8251
3×240+2×120 18.4/13.5 2.2/1.6 2.9 62.9 10570
3×300+2×150 21.0/14.9 2.4/1.8 3.1 70.4 13164
3×400+2×185 23.4/16.5 2.6/2.0 3.3 77.7 16621


VV-0.6/1kVCable Structure Data Table Table 8
Mode
mm2
Conductor Diameter        mm Insulation Nominal Thickness
mm
Sheath Nominal Thickness mm Cable Dia. mm Cable Approx weight
kg/km
4×2.5+1×1.5 1.78/1.38 0.8/0.8 1.8 13.4 259
4×4+1×2.5 2.25/1.78 1.0/0.8 1.8 15.6 370
4×6+1×4 2.76/2.25 1.0/1.0 1.8 17.1 488
4×10+1×6 4.0/2.76 1.0/1.0 1.8 20.0 699
4×16+1×10 5.0/4.0 1.0/1.0 1.8 22.8 1002
4×25+1×16 6.1/5.0 1.2/1.0 1.8 26.9 1496
4×35+1×16 7.2/5.0 1.2/1.0 1.8 29.4 1898
4×50+1×25 8.4/6.1 1.4/1.2 2.0 34.1 2584
4×70+1×35 10.0/7.2 1.4/1.2 2.1 38.3 3545
4×95+1×50 12.0/8.4 1.6/1.4 2.3 44.9 4871
4×120+1×70 13.0/10.0 1.6/1.4 2.5 48.2 6071
4×150+1×70 14.9/10.0 1.8/1.4 2.6 53.7 7335
4×185+1×95 16.5/12.0 2.0/1.6 2.8 59.6 9186
4×240+1×120 18.4/13.5 2.2/1.6 3.0 65.9 11847
4×300+1×150 21.0/14.9 2.4/1.8 3.2 73.9 14779
4×400+1×185 23.4/16.5 2.6/2.0 3.5 81.7 18761

 


VV-0.6/1kV Long-term allowable current carrying capacity of the cable9
No.of Core Single Core Two core Three ~Five core
permutation
 
1)
 
2)
 
3)
 
3)
Cross section mm2 Carrying Capacity A
2.5 24 31 25 21
4 32 41 53 28
6 40 52 42 36
10 55 70 58 49
16 74 97 76 66
25 95 120 98 84
35 115 150 120 100
50 140 180 145 125
70 180 230 185 160
95 220 280 230 195
120 255 325 265 235
150 295 375 305 260
185 340 430 350 305
240 405 515 360
300 470 595 410
400 550 700 485
500 635 810
630 735 950
800 830 1090
Work Temperature 70ºC
Environment Temperature 40ºC

 

Table of Correction Coefficient of Carrying Current at Different Ambient Temperature Table 10  
  •  
Conductor operating temperature
  •  
(ºC)
Environment Temperature(ºC)(In Air )
10 15 20 25 30 35 40 45
70 1.30 1.30 1.29 1.22 1.15 1.08 1.00 0.91
Detailed Photos

 

VV Rated voltage 0.6/1kV copper core PVC insulated PVC sheathed power cable

 

 


 
 
 
 
 
 
 
Certifications

VV Rated voltage 0.6/1kV copper core PVC insulated PVC sheathed power cable



Our factory


 
 
 

 
workshop

 

 
 
 

Inspection

 

Packaging & Shipping

 

 
 
 
 

We are China IEC60502 Copper Conductor PVC Sheath Underground Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION