Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable

Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
The cable sales avanue is USD 3.7 Billion in 2023.
A China top 10 cable manufacturer with 30 years cable production experience.
Cable model
V V 72-0.6/1kV ,V V 32-0.6/1kV
scope of application
This product is suitable for power supply and distribution energy in lines with AC 50Hz and rated voltage not exceeding 0.6 / 1kV.
construction of cable
electric conductor
Class 1 or class 2 of copper conductor
insulation
PVC (PVC)
Filled (optional)
Polypropylene mesh tear cord
Inner sheath PVC
armour
Aluminum wire or stainless steel wire
(single core)
Galvanized steel wire (multi-core)
oversheath
PVC
product standard
GB/T 12706.1,IEC 60502-1
Specifications range
1 core: 10~630mm2
2 cores: 1.5~400mm2
3-core: 1.5~400mm2
4-core: 1.5~400mm2
5-core: 1.5~400mm2
3 + 1 core: 2.5~400mm2
3 + 2 core: 2.5~400mm2
4 + 1 core: 2.5~400mm2
Wire core recognition
2 core: red blue
3 core: yellow green red or red blue yellow / green
4 core: yellow green red blue
5 core: yellow green red blue yellow / green
technical parameter
rated voltage (U0/U )
0.6/1kV
Maximum system voltage (Um)
1.2kV
temperature grade
Maximum operating temperature of the conductor: + 70ºC
Ambient temperature: -20ºC ~ + 45ºC
Cable laying temperature: not less than 0ºC (if the ambient temperature is less than 0ºC, the cable shall be preheated)
minimum bending radius
Single-core cable: 15D
Multi-core cable: 12D
Note: D, which is the actual outer diameter of the cable
Laying method
Pipe-through laying, shallow channel laying, cable trench laying, tunnel laying, interlayer laying, supporting overhead laying, hanging overhead laying, etc.
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation mm | Inner sheath thickness m m |
metal wire nominal diameter mm |
Outer sheath Nominal thickness of mm |
cable Approximately outer diameter mm |
The approximate weight of the cable kg / km | |
Stainless steel wire armor | aluminium wire armour |
|||||||
1×10 | 4.0 | 1.0 | 1.0 | 0.8 | 1.4 | 13.1 | 353 | / |
1×16 | 5.0 | 1.0 | 1.0 | 0.8 | 1.4 | 14.1 | 437 | / |
1×25 | 6.1 | 1.2 | 1.0 | 0.8 | 1.4 | 15.6 | 571 | / |
1×35 | 7.2 | 1.2 | 1.0 | 0.8 | 1.4 | 16.7 | 690 | / |
1×50 | 8.4 | 1.4 | 1.0 | 1.25 | 1.5 | 19.4 | 1003 | 775 |
1×70 | 10.0 | 1.4 | 1.0 | 1.25 | 1.5 | 21.0 | 1256 | 1002 |
1×95 | 12.0 | 1.6 | 1.0 | 1.25 | 1.6 | 23.7 | 1613 | 1320 |
1×120 | 13.0 | 1.6 | 1.0 | 1.6 | 1.7 | 25.6 | 2021 | 1627 |
1×150 | 14.9 | 1.8 | 1.0 | 1.6 | 1.7 | 27.9 | 2409 | 1961 |
1×185 | 16.5 | 2.0 | 1.0 | 1.6 | 1.8 | 30.1 | 2845 | 2365 |
1×240 | 18.4 | 2.2 | 1.0 | 1.6 | 1.9 | 32.6 | 3520 | 2987 |
1×300 | 21.0 | 2.4 | 1.2 | 2.0 | 2.0 | 37.2 | 4542 | 3792 |
1×400 | 23.4 | 2.6 | 1.2 | 2.0 | 2.1 | 40.3 | 5547 | 4714 |
1×500 | 26.6 | 2.8 | 1.2 | 2.0 | 2.2 | 44.1 | 6788 | 5871 |
1×630 | 30.0 | 2.8 | 1.2 | 2.0 | 2.4 | 47.9 | 8293 | 7293 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | Inner sheath thickness mm | Nominal diameter of the armour wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
2×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 14.6 | 341 |
2×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 15.4 | 387 |
2×4 | 2.25 | 1.0 | 1.0 | 0.8 | 1.8 | 17.2 | 483 |
2×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 19.1 | 679 |
2×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 21.5 | 859 |
2×16 | 5.0 | 1.0 | 1.0 | 1.25 | 1.8 | 23.5 | 1059 |
2×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 27.2 | 1535 |
2×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.8 | 29.4 | 1828 |
2×50 | 8.4 | 1.4 | 1.0 | 1.6 | 1.9 | 33.1 | 2285 |
2×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.0 | 37.9 | 3157 |
2×95 | 12.0 | 1.6 | 1.2 | 2.0 | 2.2 | 43.1 | 4049 |
2×120 | 13.0 | 1.6 | 1.2 | 2.0 | 2.3 | 45.3 | 4654 |
2×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.4 | 51.6 | 6050 |
2×185 | 16.5 | 2.0 | 1.4 | 2.5 | 2.6 | 56.0 | 7135 |
2×240 | 18.4 | 2.2 | 1.4 | 2.5 | 2.8 | 61.0 | 8662 |
2×300 | 21.0 | 2.4 | 1.6 | 2.5 | 2.9 | 67.7 | 10490 |
2×400 | 23.4 | 2.6 | 1.6 | 2.5 | 3.2 | 73.9 | 12753 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | Inner sheath thickness mm | Nominal diameter of the armoured wire mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable kg / km |
3×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 15.1 | 376 |
3×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 15.9 | 432 |
3×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 18.8 | 680 |
3×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 19.8 | 776 |
3×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 22.5 | 1009 |
3×16 | 5.0 | 1.0 | 1.0 | 1.25 | 1.8 | 24.6 | 1265 |
3×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 28.6 | 1855 |
3×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.8 | 31.2 | 2248 |
3×50 | 8.4 | 1.4 | 1.0 | 1.6 | 2.0 | 35.1 | 2835 |
3×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.1 | 40.2 | 3962 |
3×95 | 12.0 | 1.6 | 1.2 | 2.0 | 2.2 | 45.6 | 5070 |
3×120 | 13.0 | 1.6 | 1.2 | 2.0 | 2.3 | 47.9 | 5923 |
3×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.5 | 54.7 | 7676 |
3×185 | 16.5 | 2.0 | 1.4 | 2.5 | 2.7 | 59.5 | 9116 |
3×240 | 18.4 | 2.2 | 1.6 | 2.5 | 2.9 | 65.3 | 11289 |
3×300 | 21.0 | 2.4 | 1.6 | 2.5 | 3.1 | 72.2 | 13681 |
3×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.4 | 80.6 | 17764 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | inside liner thickness mm |
Nominal diameter of the armour wire mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
4×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 15.9 | 422 |
4×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 16.8 | 489 |
4×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 19.9 | 767 |
4×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 21.1 | 897 |
4×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 24.1 | 1184 |
4×16 | 5.0 | 1.0 | 1.0 | 1.6 | 1.8 | 27.2 | 1663 |
4×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 31.1 | 2228 |
4×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.9 | 33.9 | 2738 |
4×50 | 8.4 | 1.4 | 1.2 | 2.0 | 2.1 | 39.6 | 3798 |
4×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.2 | 43.7 | 4846 |
4×95 | 12.0 | 1.6 | 1.4 | 2.5 | 2.4 | 51.4 | 6802 |
4×120 | 13.0 | 1.6 | 1.4 | 2.5 | 2.5 | 54.0 | 7913 |
4×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.7 | 60.0 | 9487 |
4×185 | 16.5 | 2.0 | 1.6 | 2.5 | 2.9 | 65.7 | 11434 |
4×240 | 18.4 | 2.2 | 1.6 | 2.5 | 3.1 | 71.7 | 14183 |
4×300 | 21.0 | 2.4 | 1.6 | 2.5 | 3.3 | 79.4 | 17208 |
4×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.6 | 88.5 | 22351 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the outer sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
5×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 16.7 | 468 |
5×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 17.8 | 553 |
5×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 21.1 | 867 |
5×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 22.5 | 1032 |
5×10 | 4.0 | 1.0 | 1.0 | 1.6 | 1.8 | 26.5 | 1518 |
5×16 | 5.0 | 1.0 | 1.0 | 1.6 | 1.8 | 29.2 | 1932 |
5×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.9 | 33.7 | 2632 |
5×35 | 7.2 | 1.2 | 1.2 | 2.0 | 2.0 | 38.2 | 3559 |
5×50 | 8.4 | 1.4 | 1.2 | 2.0 | 2.2 | 43.0 | 4495 |
5×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.3 | 47.5 | 5756 |
5×95 | 12.0 | 1.6 | 1.4 | 2.5 | 2.5 | 55.9 | 8080 |
5×120 | 13.0 | 1.6 | 1.4 | 2.5 | 2.7 | 59.0 | 9457 |
5×150 | 14.9 | 1.8 | 1.6 | 2.5 | 2.9 | 66.0 | 11477 |
5×185 | 16.5 | 2.0 | 1.6 | 2.5 | 3.0 | 71.7 | 13732 |
5×240 | 18.4 | 2.2 | 1.8 | 3.15 | 3.3 | 80.3 | 18105 |
5×300 | 21.0 | 2.4 | 1.8 | 3.15 | 3.6 | 89.0 | 22013 |
5×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.9 | 97.2 | 27030 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
3×2.5+1×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 16.6 | 472 |
3×4+1×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 19.3 | 728 |
3×6+1×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 20.7 | 860 |
3×10+1×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 23.2 | 1097 |
3×16+1×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 26.5 | 1576 |
3×25+1×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.8 | 29.8 | 2070 |
3×35+1×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 32.3 | 2471 |
3×50+1×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.0 | 37.8 | 3451 |
3×70+1×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 41.6 | 4383 |
3×95+1×50 | 12.0/8.4 | 1.6/1.4 | 1.2 | 2.0 | 2.3 | 47.3 | 5659 |
3×120+1×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 51.8 | 7239 |
3×150+1×70 | 14.9/10.0 | 1.8/1.4 | 1.4 | 2.5 | 2.6 | 56.6 | 8475 |
3×185+1×95 | 16.5/12.0 | 2.0/1.6 | 1.4 | 2.5 | 2.7 | 61.8 | 10205 |
3×240+1×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 2.9 | 67.6 | 12601 |
3×300+1×150 | 21.0/14.9 | 2.4/1.8 | 1.6 | 2.5 | 3.1 | 74.8 | 15277 |
3×400+1×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.4 | 83.5 | 19791 |
V V 32-0.6/1kV Cable structure parameters Table 7
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath layer thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
3×2.5+2×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 17.4 | 518 |
3×4+2×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 20.3 | 797 |
3×6+2×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 22.0 | 963 |
3×10+2×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 25.3 | 1369 |
3×16+2×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 28.2 | 1768 |
3×25+2×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.8 | 32.0 | 2352 |
3×35+2×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 34.2 | 2745 |
3×50+2×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 40.2 | 3885 |
3×70+2×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.2 | 44.3 | 4921 |
3×95+2×50 | 12.0/8.4 | 1.6/1.4 | 1.4 | 2.5 | 2.4 | 51.9 | 6839 |
3×120+2×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 55.2 | 8175 |
3×150+2×70 | 14.9/10.0 | 1.8/1.4 | 1.4 | 2.5 | 2.7 | 59.9 | 9395 |
3×185+2×95 | 16.5/12.0 | 2.0/1.6 | 1.6 | 2.5 | 2.8 | 66.2 | 11550 |
3×240+2×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 3.0 | 72.1 | 14160 |
3×300+2×150 | 21.0/14.9 | 2.4/1.8 | 1.6 | 2.5 | 3.3 | 79.8 | 17214 |
3×400+2×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.6 | 89.0 | 22205 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath layer thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
4×2.5+1×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 17.6 | 536 |
4×4+1×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 20.7 | 832 |
4×6+1×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 22.2 | 996 |
4×10+1×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 25.8 | 1433 |
4×16+1×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 28.6 | 1847 |
4×25+1×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 32.9 | 2489 |
4×35+1×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 2.0 | 35.6 | 3001 |
4×50+1×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 41.5 | 4180 |
4×70+1×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.3 | 45.9 | 5343 |
4×95+1×50 | 12.0/8.4 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 53.9 | 7484 |
4×120+1×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.6 | 57.0 | 8809 |
4×150+1×70 | 14.9/10.0 | 1.8/1.4 | 1.6 | 2.5 | 2.8 | 63.1 | 10473 |
4×185+1×95 | 16.5/12.0 | 2.0/1.6 | 1.6 | 2.5 | 2.9 | 68.8 | 12628 |
4×240+1×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 3.2 | 75.3 | 15657 |
4×300+1×150 | 21.0/14.9 | 2.4/1.8 | 1.8 | 3.15 | 3.4 | 85.0 | 20095 |
4×400+1×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.7 | 92.8 | 24603 |
- Imported equipment with experienced technical team
The company have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X – RAY 8000 on-line eccentricity measuring unit from Germany - Complete certification system
Qifan Cable have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate. - Perfect Production system
Qifan Cable products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc. - Perfect Sales service system
Qifan Cable can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service. Qifan is always your best choice.
We are China Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: Copper Armoured Cable, Ltd., Shanghai QIFAN Cable Co., Swa Armoured Power Cable