Product Description
0.6/1kv Bttw/Yttw, Fire Resistant Cable Multi Cores Inorganic Mineral Insulated Corrugated Copper/LSZH Sheath Power Cable
I Product Details
BTTW/YTTW Metal Sheathed Inorganic Mineral Insulated Cable
Flexible fireproof cable and copper sheath embossing mineral insulated cable. The cable is a new fireproof cable defects based on modified insulated cables in mineral, it can overcome the disadvantages of mineral insulated cable production is limited by the length of the middle joint installation, avoid appearing in question, has the advantages of the insulation layer is not easy to damp, installation convenience, with the continuous promotion of the product excellent performance, they are increasingly affected by the broad masses of customers, it has been widely used in industrial and civil construction.
II Properties
Fireproof performance, fire resistance rating will not only meet the national standard GB12666.6A 950 degree Celsius, 90min, but also to meet the provisions of the United Kingdom BS6387-1994 A Grade of 650 degree Celsius 3H; B 750 degree Celsius 3H; C 950 degree Celsius 3H requirements; At the same time, in the combustion can tolerance water spray and mechanical impact; 2, continuous length, whether it is single core, or multi-core cable, its length can satisfy the power supply need of length, above each continuous lengths up to 1000m; 3, section of a large, single core cable section is 630mm2, multicore cables up to 70mm2; 4, with flexible, cable disc in the disc, the bending radius is 6-10D; 5, burning smoke-free non-toxic using inorganic materials, insulation, does not produce any harmful gas during burning, no 2 pollution, is the real green environmental protection products; 6, the overload capacity is large, the cable ampacity not only large, but also has large overload capacity. According to the wiring to be shown, usually cable surface temperature ≤ 70 degree Celsius, if the wiring can not touch, nor with the combustible materials in contact, cable sheathing temperature up to 105 degree Celsius. Overload fireproof cable long-term working temperature can reach 250 degree Celsius 7, corrosion resistance, good shielding property, the copper sheath good corrosion resistance, in particular or corrosion of the copper environment, should be applied a layer of low smoke zero halogen or plastic external protecting layer on the copper sheath. In the shielded copper sheath, no electromagnetic interference, have not the signal, control cable transmission information interference 8, good safety, fire cable to normal power supply in the flame (normal power supply 950 degree Celsius for more than 3 hours), starting a fire extinguisher, reducing fire loss. The copper sheath is a good conductor, grounding is best, greatly improve the sensitivity and reliability of grounding protection 9, long service life, high temperature is not easy to aging, in the normal condition, its service life is more than 100 years. 10, flexible fire-proof cable transportation, installation, assembly is simple, similar to that of an ordinary cable, 11, economical, flexible fire-proof cable because of advanced technology, simple installation, low in the same conditions the comprehensive cost than mineral insulated cable charges.
III Scope of Application
Shopping mall, department store, hospital, school, stadium, exhibition center, train station, airport, subway, commercial buildings, hotels, places with dense population, iron and steel enterprises, 100 meters above the building.
Two Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
2×2.5 | 10 | 0.8 | 8 | 7.41 |
2×4 | 15 | 0.8 | 9.3 | 4.61 |
2×6 | 17 | 0.8 | 10.7 | 3.08 |
2×10 | 39 | 1 | 14.2 | 1.83 |
2×16 | 45 | 1 | 16.8 | 1.5 |
2×25 | 54 | 1 | 19.3 | 0.727 |
2×35 | 67 | 1.1 | 21.55 | 0.524 |
2×50 | 82 | 1.2 | 19.7 | 0.387 |
2×70 | 96 | 1.2 | 21.9 | 0.268 |
2×95 | 110 | 1.2 | 24.1 | 0.193 |
2×120 | 126 | 1.2 | 25 | 0.153 |
Three Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
3×2.5 | 13.6 | 0.8 | 8.8 | 7.41 |
3×4 | 15.4 | 0.8 | 10.2 | 4.61 |
3×6 | 17.4 | 0.8 | 11.3 | 3.08 |
3×10 | 27.7 | 1 | 14.8 | 1.83 |
3×16 | 32.3 | 1 | 17.7 | 1.5 |
3×25 | 44.3 | 1 | 20.4 | 0.727 |
3×35 | 57.8 | 1.1 | 22.7 | 0.524 |
3×50 | 66.2 | 1.2 | 22.8 | 0.387 |
3×70 | 85.8 | 1.2 | 25.6 | 0.268 |
3×95 | 98.1 | 1.2 | 28.5 | 0.193 |
3×120 | 108.7 | 1.2 | 31.3 | 0.153 |
3+1 Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
3×16+1×10 | 41.6 | 1 | 18.8 | 1.665 |
3×25+1×16 | 55.9 | 1 | 21.6 | 1.1135 |
3×35+1×16 | 69.6 | 1.1 | 23.7 | 1.012 |
3×50+1×25 | 81.2 | 1.2 | 24.3 | 1.557 |
3×70+1×35 | 93.6 | 1.2 | 28.2 | 0.396 |
3×95+1×50 | 106.4 | 1.2 | 32.8 | 0.29 |
3×120+1×70 | 132.2 | 1.2 | 37.2 | 0.2105 |
Four Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
4×6 | 20 | 0.8 | 12.6 | 3.08 |
4×10 | 31.9 | 1 | 16.9 | 1.83 |
4×16 | 43.2 | 1 | 19.2 | 1.5 |
4×25 | 58.1 | 1 | 22.2 | 0.727 |
4×35 | 74.9 | 1.1 | 24.9 | 0.524 |
4×50 | 85.8 | 1.2 | 25 | 0.387 |
4×70 | 99.5 | 1.2 | 28.2 | 0.268 |
4×95 | 113.9 | 1.2 | 32.2 | 0.193 |
4×120 | 139.6 | 1.2 | 35 | 0.153 |
- Imported equipment with experienced technical team
The company have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X – RAY 8000 on-line eccentricity measuring unit from Germany - Complete certification system
Qifan Cable have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate. - Perfect Production system
Qifan Cable products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc. - Perfect Sales service system
Qifan Cable can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service. Qifan is always your best choice.
We are China Mica Insulated Flexible Halogen Free Low Smoke Sheathed Fire Proof Copper Power Cable Yttwy 0.6/1kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Fire Proof Cable Products
Popular Ltd. Products
Low Carbon Steel Q235 SAE1010 SAE1020 Lighting Protection System Grounding Rod 3/4′′
Low and Medium Voltage Red Copper Wire Esp Price Motor Cable
Factory Supply Different Size AAC AAAC Aluminum Alloy Conductor 75mm2 100mm2
Medium Voltage Electrical Wire Copper/Aluminum Conductor XLPE Insulated Power Cable
Rg58 Rg59 Signal Cables Rg 59 Coaxial Cable TV Cables TV Wire
Popular Mica Insulated Cable Products
Popular Shanghai QIFAN Cable Co. Products
8.7/15 (17.5) Kv Copper/ Aluminum Conductor Single Core 95mm2 XLPE Insulated Cts Awa Armored Cable
300/500V H05VV-F Cable Multicore 1.5mm2 Rvv
3.6/6kv Medium Voltage Single Core 70mm2 XLPE Insulation Power Cable
450V/750V Twin Core Flat Cable Earth Flat TPS Cable for Australian Market
19/33kv Medium Voltage Single Core Copper Conductor 500mm2 630mm2 Cu/XLPE/Cws /PVC Cable
Tags: Fire Proof Cable, Ltd., Mica Insulated Cable, Shanghai QIFAN Cable Co.