3.8/6.6 (7.2) Kv U/G Cables 6.6kv, XLPE, 3X185mm2 Copper Conductor BS-6622 IEC 60502
                         3.8/6.6 (7.2) Kv U/G Cables 6.6kv, XLPE, 3X185mm2 Copper Conductor BS-6622 IEC 60502 image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
1. Application and Main type
| 
 Type  | 
 Description  | 
 Main Application  | 
|
| 
 Copper Conductor  | 
 Aluminum Conductor  | 
||
| 
 YJV Cu/XLPE/PVC  | 
 YJLV Al/XLPE/PVC  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen PVC sheathed power cable  | 
 For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid.  | 
| 
 YJV Cu/XLPE/L(H)DPE  | 
 YJLV Al/XLPE/L(H)DPE  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen PE/LDPE/HDPE sheathed power cable  | 
|
| 
 YJE Cu/XLPE/LSOH  | 
 YJLE Al/XLPE/LSOH  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen LSOH sheathed power cable  | 
|
| 
 YJSV Cu/XLPE/CWS/PVC N2XS(SE)Y  | 
 YJLSV Al/XLPE/CWS/PVC N2XS(SE)Y  | 
 Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen PVC sheathed power cable  | 
 
 For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid, fault current requires large. CWS(Copper wire screen) type: A: Fixed section B: Full/one third/one sixth/one eighth/one sixteenth neutral  | 
| 
 YJSY Cu/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y  | 
 
 YJLSY Al/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y  | 
 Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen PE/LDPE/HDPE sheathed power cable  | 
|
| 
 YJE Cu/XLPE/CWS/LSOH  | 
 YJLE Al/XLPE/CWS/LSOH  | 
 Copper or aluminum conductor XLPE Copper wire+ Copper tape screen LSOH sheathed power cable  | 
|
| 
 YJV22 Cu/XLPE/STA/PVC  | 
 YJLV22 Al/XLPE/STA/PVC  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PVC sheathed power cable  | 
 
 For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force.  | 
| 
 YJV23 Cu/XLPE/STA/L(M.H)PE  | 
 YJLV23 Al/XLPE/STA/L(M.H)PE  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PE/LDPE/HDPE sheathed power cable  | 
|
| 
 WD-YJY23 Cu/XLPE/STA/LSOH  | 
 WD-YJLY23 Al/XLPE/STA/LSOH  | 
 Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PVC sheathed power cable 
  | 
|
| 
 YJSV22 Cu/XLPE/CWS/STA/PVC N2XSEBY  | 
 YJLSV22 Al/XLPE/CWS/STA/PVC N2XSEBY  | 
 Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen, steel tape armored, PVC sheathed power cable  | 
 
 For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large. CWS(Copper wire screen) type: A: Fixed section  | 
2. Scope of voltage grade and core number and cross-section
a) National standard
| 
 Rated voltage(KV)  | 
 3.6/6  | 
 6/6  | 
 6/10  | 
 8.7/10  | 
 8.7/15  | 
 12/15  | 
 12/20  | 
 18/20  | 
 18/30  | 
 21/35  | 
 26/35  | 
|
| 
 Core Number  | 
 1 core, 3 core  | 
|||||||||||
| 
 Cross-section mm2  | 
 1C  | 
 25~800  | 
 35~800  | 
|||||||||
| 
 3C  | 
 25~400  | 
 35~400  | 
||||||||||
b) IEC/BS/DIN standard
| 
 Rated voltage(KV)  | 
 3.6/6  | 
 6/6  | 
 6/10  | 
 8.7/10  | 
 8.7/15  | 
 12/15  | 
 12/20  | 
 18/20  | 
 18/30  | 
 21/35  | 
 26/35  | 
|
| 
 Core Number  | 
 1 core, 3 core  | 
|||||||||||
| 
 Cross-section mm2  | 
 1C  | 
 25~800  | 
 35~800  | 
|||||||||
| 
 3C  | 
 25~400  | 
 35~400  | 
||||||||||
c) ASTM standard
| 
 Rated voltage(KV)  | 
 5001-8000  | 
 8001-15000  | 
 15001-25000  | 
 25001-28000  | 
 28001-35000  | 
 35001-46000  | 
|
| 
 1 core, 3 core  | 
|||||||
| 
 Cross-section mm2  | 
 1C  | 
 6AWG~1600kcmil  | 
 2AWG~1600kcmil  | 
 1AWG~1600kcmil  | 
 2AWG~1600kcmil  | 
 1/0AWG~1600kcmil  | 
|
| 
 
 3C  | 
 6AWG~1600kcmil  | 
 2AWG~1600kcmil  | 
 1AWG~1600kcmil  | 
 2AWG~1600kcmil  | 
 4/0AWG~1600kcmil  | 
||
3. Service conditions and operation parameters of cable
A) Max. conductor operating temperature: 90oC
B) Short circuit temperature: 250oC
C) Ambient temperature: 30oC
D) Soil temperature: 20oC
E) Depth of laying in direct: 0.8m
F) Thermal resistance of soil: 150oC.cm/W
G) Thermal resistance of ducts: 120oC.cm/W
We are China 3.8/6.6 (7.2) Kv U/G Cables 6.6kv, XLPE, 3X185mm2 Copper Conductor BS-6622 IEC 60502 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: 3.8/6.6kv, 3X185mm2 Copper Conductor BS-6622 IEC 60502, 6.6kv, XLPE, YIFANG ELECTRIC GROUP INC.
				
					
                                    
                                    
                                    
                                    
                                    
                                    
                                    
                                    