12AWG Copper Electrical Wire 3.5mm2 Stranded Wire

China 12AWG Copper Electrical Wire 3.5mm2 Stranded Wire  manufacture and supplier

12AWG Copper Electrical Wire 3.5mm2 Stranded Wire image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
THW TW THHN THWN
Application
Overhead, Heating, Underground
Conductor Material
Copper
Sheath Material
PVC
Insulation Material
PVC
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC
Brand
OEM
Cores
1 Cores
Transport Package
in Roll
Specification
12 14 10 8 6 1 6 4
Trademark
HENAN HONGDA
Origin
China
HS Code
8544422900
Production Capacity
10000 M Per Day

Product Description

Application

  • When used as type THHN/THWN-2, conductors are suitable for use in wet or dry locations at temperatures not to exceed 90°C both dry and wet locations or not to exceed 75°C exposed to oil and gasoline.
  • For 50mm²-500mm², Cable tray (CT) rated THHN/THWN-2 can be installed in Cable Trays

Specification

  • The THHN/THWN-2 conductors are designed according to local and internationally recognized and accepted standards: ASTM: B3, B8
  • ASTM: B3, B8
  • Underwriters Laboratory: Listed under file #E-55448 for AWG Conductor sizes
  • PNS: 35, 260, and 1207 Specification
  • PEC 2009 Article 3.18 compliant for Cable tray
  • NEC Article 318 compliant for Cable tray

Features

  • Designed to operate at a maximum conductor temperature of 90°C both for wet and dry locations
  • Higher cable ampacity
  • Available in six standard colors (red, black, white, green, yellow, and blue)
  • Jacketed with nylon for mechanical protection; greater resistance against abrasion, resistance to petroleum by-products, chemical agents and oils, and termite resistant.
  • With sequential cable marker printed on the cable surface for sizes 38mm² up to 500mm² to indicate the length of the cable, act as cable usage reference and for inventory control
  • Residential Homes
  • Residential & Commercial Buildings (Mixed Use)
  • Industrial/Manufacturing Buildings/Facilities
  • Power Utliities
  • Distributions/Transmissions
  • Power Generation/Industrial Plants/Renewables
  • Telcoms Distribution
  • Data Centers
  • Cell Sites
  • Special Buildings such as infra projects (airports/LRT-Train/Subways)

COPPER BUILDING WIRE TYPE THHN/THWN – 2

Copper 600V 90°C Dry or Wet PVC Insulated and Polyamide (Nylon) Jacketed, Single Core

 

Sizes Equivalent sizes Conductor diameter Cable Diameter Cable weight Cable ampacity Packaging scheme
    mm mm kg/km A** m
1.6mm solid 14 awg 1.6 2.6 22 25+ 150m
2.0mm solid 12 awg 2.0 3.0 33 30+ 150m
2.6mm solid 10 awg 2.6 3.8 55 40+ 150m
3.2mm solid 8 awg 3.2 5.1 88 55+ 150m
2.0mm2 strands 14 awg 1.8 2.8 24 25+ 150m
3.5mm2 strands 12 awg 2.3 3.3 37 30+ 150m
5.5mm2 strands 10 awg 2.9 4.1 58 40+ 150m
8.0mm2 strands 8 awg 3.6 5.5 96 55 150m
14mm2 strands 6 awg 4.6 6.5 147 70 150m
22mm2 strands 4 awg 5.7 8.1 232 90 150m
30mm2 strands 2 awg 6.7 9.0 311 115 150m
38mm2 strands 1 awg 7.8 10.8 414 130 300m
50mm2 strands 1/0 awg 8.8 11.8 514 150 300m
60mm2 strands 2/0 awg 9.8 12.7 625 170 300m
80mm2 strands 3/0 awg 11.2 14.2 813 205 300m
100mm2 strands 4/0 awg 12.7 15.7 1026 225 300m
125mm2 strands 250 mcm 14.3 17.8 1298 265 300m
150mm2 strands 300 mcm 15.7 19.3 1556 295 300m
175mm2 strands 350 mcm 17.0 20.8 1741 325 300m
200mm2 strands 400 mcm 17.8 21.4 1967 355 300m
250mm2 strands 500 mcm 20.2 23.8 2519 400 300m
300mm2 strands 600 mcm 22.3 26.3 2964 447 300m
325mm2 strands 650 mcm 22.9 26.9 3218 470 300m
375mm2 strands 750 mcm 25.0 29.6 3677 500 300m
400mm2 strands 800 mcm 25.5 29.7 3974 515 300m
500mm2 strands 1000 mcm 28.2 32.2 4809 580 300m

 

*Unless otherwise specifically permitted, the overcurrent protection shall both exceed 15A for 2.0mm2 (1.6mm); 20A for 3.5mm2 (2.0mm) and 25A for 5.5mm2 as per PEC.
**Ampacity is based on 90°C not more than three current carrying conductors in conduit based on ambient temperature of 30°C as per PEC 2000.
***Effective impedance for three conductors in conduit 60Hz, 75°C and 600 Volts at P.F. multiplying current by effective impedance gives a good approximation for line to
neutral voltage drop.
+Diagrams of cables are illustrative only and not necessarily to scale. PDP reserves the right to change or vary the construction of any of their products without notice.
While every care has been taken in the preparation of this data sheet, PDP accept no liability of any kind and are not responsible for the results of any actions taken on
the basis of this information or resulting from errors or omissions. This technical data sheet is intended as a guide only; any person using it must make reference to
the appropriate local standards or authorities.

We are China 12AWG Copper Electrical Wire 3.5mm2 Stranded Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Tags: ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION