Single Core Awa Aluminium Wire Armored Yjlv72 Aluminium Conductor Armoured XLPE Insulated PVC Sheathed Power Cable

Single Core Awa Aluminium Wire Armored Yjlv72 Aluminium Conductor Armoured XLPE Insulated PVC Sheathed Power Cable image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
Scope of application
System
The product is suitable for fixed laying in the distribution network or industrial installations with AC 50Hz and rated voltage 3.6/6kV,6/6/6kV,6/10kV,8.7/10kV, 8.7/15kV ,12/20kV,18/30kV,21/35kV 26/35kV.
Occasion
Fixed in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution. For example, it can be used in power distribution and other places within industrial and mining enterprises.
Product characteristics
It has the characteristics of high normal operating temperature of conductor, simple structure, easy to use and not limited by laying drop.
Standards Compliant
Implementation Standards
GB/T 12706-2020 Rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cables and accessories.
Additional standard
Usage features
Rated voltage
The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/150kV, and the maximum voltage of the AC system should not exceed 17.5kV.
The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.
The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.
The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously The time does not exceed 5s.
Ambient Temperature
Minimum working environment temperature -10ºC.
Laying Temperature
The laying temperature of cables should not be lower than 0ºC.
Bending Radius
The minimum bending radius of single-core cable without armour is recommended to be 20D. The minimum bending radius of single-core cable with armour is recommended to be 15D. The minimum bending radius of three-core cable without armour is recommended to be 15D. The minimum bending radius of three-core cable with armour is recommended to be 12D.
Note: D is the outer diameter of the cable.
Product Identification
Core
Color code
1 core: omitted
3 cores: red, yellow, green (add color ribbon)
Sheath
The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer’s name, product model, rated voltage, and the manufacturer’s name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete logo and the beginning of the next logo should not exceed 500mm on the outer sheath of the cable; it should not exceed 200mm on the cable insulation or tape; the printed logo should be scratch-resistant and not fall off, and the printing on the surface Content should be clear and legible.
Note: The mark on the surface of the sheath can also add other content according to the custom of the user or the manufacturer.
specification | conductor structure | Outer diameter of conductor(mm) | insulation thickness (mm) |
Tape specification(mm) | Inner sheath thickness(mm) | Armor specification(mm) | Thickness of outer sheath(mm) | Reference outside diameter(mm) | Reference weight(kg/km) | 20ºC maximum DC resistance(Ω/km) | Minimum insulation resistance at operating temperature(MΩ·km) | testing voltage (kV/min) |
Maximum allowable tractive force of conductor(N) |
1×10 | 7/1.35 | 4.05 | 0.7 | 20×0.20 | 1 | 33×0.8 | 1.8 | 13.7 | 319.8 | 3.08 | 3.67 | 3.5/5 | 400 |
1×16 | 7/1.66 | 4.98 | 0.7 | 20×0.20 | 1 | 37×0.8 | 1.8 | 14.7 | 367.1 | 1.91 | 3.67 | 3.5/5 | 640 |
1×25 | 7/2.14 | 6.42 | 0.9 | 20×0.20 | 1 | 44×0.8 | 1.8 | 16.5 | 458.1 | 1.2 | 3.67 | 3.5/5 | 1000 |
1×35 | 7/2.52 | 7.56 | 0.9 | 20×0.20 | 1 | 48×0.8 | 1.8 | 17.7 | 522.3 | 0.868 | 3.67 | 3.5/5 | 1400 |
1×50 | 10/2.52 | 8.4 | 1 | 25×0.20 | 1 | 33×1.25 | 1.8 | 19.7 | 706.4 | 0.641 | 3.67 | 3.5/5 | 2000 |
1×70 | 14/2.52 | 10 | 1.1 | 30×0.20 | 1 | 38×1.25 | 1.8 | 21.5 | 842.2 | 0.443 | 3.67 | 3.5/5 | 2800 |
1×95 | 19/2.52 | 11.6 | 1.1 | 35×0.20 | 1 | 41×1.25 | 1.8 | 23.1 | 968.5 | 0.32 | 3.67 | 3.5/5 | 3800 |
1×120 | 24/2.52 | 13 | 1.2 | 40×0.20 | 1 | 36×1.6 | 1.8 | 25.4 | 1253.9 | 0.253 | 3.67 | 3.5/5 | 4800 |
1×150 | 30/2.52 | 14.6 | 1.4 | 45×0.20 | 1 | 40×1.6 | 1.8 | 27.4 | 1441.1 | 0.206 | 3.67 | 3.5/5 | 6000 |
1×185 | 37/2.52 | 16.2 | 1.6 | 50×0.20 | 1 | 43×1.6 | 1.8 | 29.4 | 1628.4 | 0.164 | 3.67 | 3.5/5 | 7400 |
1×240 | 48/2.52 | 18.5 | 1.7 | 55×0.20 | 1 | 48×1.6 | 1.9 | 32.1 | 1922.8 | 0.125 | 3.67 | 3.5/5 | 9600 |
1×300 | 61/2.52 | 20.6 | 1.8 | 60×0.20 | 1 | 52×1.6 | 1.9 | 34.4 | 2210.6 | 0.1 | 3.67 | 3.5/5 | 12000 |
1×400 | 61/2.94 | 23.3 | 2 | 60×0.20 | 1.2 | 48×2.0 | 2.1 | 39.6 | 3011.2 | 0.0778 | 3.67 | 3.5/5 | 16000 |
1×500 | 60/3.29 | 26.6 | 2.2 | 60×0.20 | 1.2 | 53×2.0 | 2.2 | 43 | 3533 | 0.0605 | 3.67 | 3.5/5 | 20000 |
1×630 | 60/3.69 | 29.6 | 2.4 | 60×0.20 | 1.2 | 58×2.0 | 2.3 | 46.6 | 4127.7 | 0.0469 | 3.67 | 3.5/5 | 25200 |
We are China Single Core Awa Aluminium Wire Armored Yjlv72 Aluminium Conductor Armoured XLPE Insulated PVC Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Henan Guowang Cable Group Co. Products
Factory 0.6/1kv 300/500V Roll Copper China Copper PVC Elevator BVV Cable
Multi Cores XLPE Cu/PVC/Sta/Swa XLPE/PVC Aluminum Cu/Al Conductor Copper Cable
Guowang Construction Armour Copper Aluminum High Quality Ug Cable Manufacture Yjv32, Yjv22
Low Voltage Multie Core Fire Resistance Lsnh Electric Flat Cable
XLPE 5 or 4 Cores 4*35*1*16mm2 4*240mm2 Armored Power Cable Manufacture Na2xy/Na2xby
10-500sqmm Aluminum BS215 Conductor ACSR AAC AAAC Acss Accc Aacsr
Popular Ltd. Products
0.6/1 Kv PVC 1 X 150 mm2 4 Core Copper Armoured Power Cable
TUV Approved Solar PV Cable Olx 4AWG 12AWG 10AWG (1X6.0mm2) Solar Cable
0.6/1kv 10kv 25kv 35kv XLPE or PVC Copper Conductor Cable 400mm2
Round Wire Guowang Pallet/According to Your Need Nylon Sheath House Wires with ISO
Bare Conductor ASTM Standard Raven 1/0 AWG ACSR Overhead Transmission Line
Popular Mv Cable Products
12/20kv (24KV) Power Cable Aluminum Conductor Galvanized Steel Wire Armour 3X300mm2
36kv Cis Hta Cable According to NFC 33226
Yjly Yjly23 8.7/10kv 3X240mm Aluminium XLPE PVC Mv Cables
3*120mm+2*70mm2 Low/Medium Voltage Na2xsh/Na2xs (F) H Cable Aluminum Conductor XLPE/PVC Power Cable
Mv/Cu& Al/ XLPE /Sta/PVC 18/30 (36) Kv Power Cable
12 Kv 400 Sqmm Single Core XLPE Copper Power Cable for Nepal Market
Popular Power Cable Products
Yjv Cable 3 Core 4 Core 5 Core Insulated Armoured Cable Copper Waterproof Low Voltage Cable
U1000 R2V RO2V Rvfv 3 4 5 Core 10mm 16mm 25mm 35mm 50mm 70mm 95mm Rigid Copper Electric Power Cable
0.6/1kv XLPE Insulated and Tray Flame-Retardant PVC Sheathed Tfr-CV Cable
Low Voltage Power Cable 3X4+1X4mm2 XLPE Insulation Armoured Flame Retardant
12/20kv 33kv 3*70mm2 3*240mm2 Copper/Aluminum Power Cable Manufacture New Design
Tags: Henan Guowang Cable Group Co., Ltd., Mv Cable, Power Cable