Overhead Aac 70mm2 Abc Cable Bare Conductor Aluminum Conductor Cable Aac
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
IEC 61089 | ||||||
Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
mm2 | No./mm | mm | kg/km | KN | ohm/km | |
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B231/B 231M | |||||||
Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
BS 215 Part 1 | |||||||
Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
BS EN 50182 | ||||||
Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Overhead AAC 70mm2 ABC Cable Bare Conductor Aluminum Conductor Cable AAC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Bare Conductor Products
Popular Henan Kingyear Aluminum Industrial Co. Products
Medium and Low Voltage XLPE/PVC/PE Insulation Armoured Power Cable
Control Cable 10 Core 2.5mm2 2.5mm3 2.5mm4
2 Core ABC Cable XLPE Insulated Aluminum Conductor
95mm2 XLPE Insulated Cable Armoured Copper Conductor Electric Power Cable
Power Cable Cu / XLPE /Cts/PVC/Sta/PVC 8.7 / 15kv 12/20 (24) Kv 3/C IEC 60502-2 Power Cable
150 mm2 1000mm2 Kabel 240mm2 Oiled AAAC Conductor Overhead Stranded Aluminum Alloy Cable
Popular Ltd. Products
Galvanized Steel Core Aluminum Hda/ACSR Conductor 100mm2 Dog Hare Hyena BS 215
ABC Cable Insulation Aerial Twisted Aluminum Cable
Low Electrical Conductivity 95mm 100mm Overhead Bare Aluminum ACSR Conductor
High Quality 75ohm Rg59 Communication Cable CCTV Rg59 RG6 Coaxial Cable
Conductor de aluminio reforzado con aleación de aluminio 481mm2 (ACAR) 950MCM
Cable 36 Kv 630mm² Halogen Free Direct Buried Cable Mt - XLPE