LV Triplex Service Drop Aluminum Conductor XLPE Insulated AAC/AAAC/ACSR ABC Power Cable

LV Triplex Service Drop Aluminum Conductor XLPE Insulated AAC/AAAC/ACSR ABC Power Cable image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
ONE-STOP SOLUTIONS FOR WIRES&CABLES – HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
2. Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene Insulation, concentric strand AAC, ACSR, OR 6201 alloy neutral messenger.
3. Standard
ASTM B-230, B-231, B-232 and B-399, IECA S-76-474
Triplex-AAC
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSENGER | ||||||||||
Patella | 6 | 7 | 45 | 6 | 7 | 563 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 1118 | 1118 | 420 | 325 |
+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2ft./sec. wind in sun. |
Triplex-AAAC
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Equiv. Dia. (AWG)++ |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 101 | 101 | 85 | 70 |
Hippa | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 107 | 107 | 85 | 70 |
Prawn | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 152 | 152 | 115 | 90 |
Barnacle | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 160 | 160 | 115 | 90 |
Shrimp | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 243 | 243 | 150 | 120 |
Gammarus | 1/0 | 7 | 60 | 1/0 | 123.3 | 7 | 4460 | 390 | 390 | 205 | 160 |
Leda | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 384 | 384 | 205 | 160 |
Dungenese | 2/0 | 7 | 60 | 2/0 | 155.4 | 7 | 5390 | 483 | 483 | 235 | 185 |
Cyclops | 2/0 | 11 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Flustra | 3/0 | 17 | 60 | 3/0 | 195.7 | 7 | 6790 | 587 | 587 | 275 | 215 |
Lepas | 4/0 | 18 | 60 | 4/0 | 246.9 | 7 | 8560 | 728 | 728 | 315 | 245 |
Triplex-AAAC Reduced
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Equiv. Dia. (AWG)++ |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 135 | 135 | 115 | 90 |
Crab | 4 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 143 | 143 | 115 | 90 |
Solaster | 2 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 216 | 216 | 150 | 120 |
Sandcrab | 1/0 | 7 | 60 | 2 | 77.47 | 7 | 2800 | 347 | 347 | 205 | 160 |
Echinus | 1/0 | 9 | 60 | 2 | 77.47 | 7 | 2800 | 341 | 341 | 205 | 160 |
Fulgar | 3/0 | 17 | 60 | 1/0 | 123.3 | 7 | 4460 | 519 | 519 | 275 | 215 |
Arca | 4/0 | 18 | 60 | 2/0 | 155.4 | 7 | 5390 | 643 | 643 | 315 | 245 |
Triplex-ACSR
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
ACSR NEUTRAL-MESSENGER | ||||||||||
Paludina | 6 | 1 | 45 | 6 | 43252 | 1190 | 109 | 109 | 85 | 70 |
Voluta | 6 | 7 | 45 | 6 | 43252 | 1190 | 114 | 114 | 85 | 70 |
Whelk | 4 | 1 | 45 | 4 | 43252 | 1860 | — | 164 | 115 | 90 |
Periwinkle | 4 | 7 | 45 | 4 | 43252 | 1860 | 172 | 172 | 115 | 90 |
Conch | 2 | 7 | 45 | 2 | 43252 | 2850 | 262 | 262 | 150 | 120 |
Neritina | 1/0 | 7 | 60 | 1/0 | 43252 | 4380 | 420 | 420 | 205 | 160 |
Cenia | 1/0 | 9 | 60 | 1/0 | 43252 | 4380 | 414 | 414 | 205 | 160 |
Runcina | 2/0 | 7 | 60 | 2/0 | 43252 | 5310 | 520 | 520 | 235 | 185 |
Triton | 2/0 | 11 | 60 | 2/0 | 43252 | 5310 | 512 | 512 | 235 | 185 |
Mursia | 3/0 | 17 | 60 | 3/0 | 43252 | 6620 | 635 | 635 | 275 | 215 |
Zuzara | 4/0 | 18 | 60 | 4/0 | 43252 | 8350 | 789 | 789 | 315 | 245 |
Limpet | 336.4 | 19 | 80 | 336.4 | 43118 | 8680 | 1167 | 1167 | 420 | 325 |
Triplex-ACSR Reduced
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
ACSR REDUCED NEUTRAL-MESSENGER | ||||||||||
Scallop | 4 | 1 | 45 | 6 | 43252 | 1190 | — | 142 | 115 | 90 |
Strombus | 4 | 7 | 45 | 6 | 43252 | 1190 | 151 | 151 | 115 | 90 |
Cockle | 2 | 7 | 45 | 4 | 43252 | 1860 | 228 | 228 | 150 | 120 |
Janthina | 1/0 | 7 | 60 | 2 | 43252 | 2853 | 366 | 366 | 205 | 160 |
Ranella | 1/0 | 9 | 60 | 2 | 43252 | 2853 | 360 | 360 | 205 | 160 |
Cavolinia | 2/0 | 7 | 60 | 1 | 43252 | 3550 | 453 | 453 | 235 | 185 |
Clio | 2/0 | 11 | 60 | 1 | 43252 | 3550 | 444 | 444 | 235 | 185 |
Aega | 3/0 | 17 | 60 | 1/0 | 43252 | 4380 | 549 | 549 | 275 | 215 |
Cerapus | 4/0 | 18 | 60 | 2/0 | 43252 | 5310 | 681 | 681 | 315 | 245 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
- Raw material inspection and test
- Production process test
- Unqualified product control
- Regular test and examination
- Finished product inspection
UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s’ Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.
We are China LV Triplex Service Drop Aluminum Conductor XLPE Insulated AAC/AAAC/ACSR ABC Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Triplex Service Drop Cable Products
2AWG Clam/Conch/Shrimp Triplex Service Drop Cable ABC Cable
Triplex Service Drop Aluminum Conductor XLPE Insulated for Supply Power Icea S-76-474
2AWG Clam/Conch/Shrimp Triplex Service Drop Cable ABC Cable
Triplex Service Drop Cable Triplex-AAC/AAAC/ACSR Aluminum Conductor ABC Cable
Popular Aerial Bundled Cable Products
Overhead Aerial Bundled Cable ABC Cable
Service Drop Wire PE/XLPE Insulated Cable
ABC Cable, Aerial Bundled Cable, 0.6/1 Kv (NF C 33-209)
0.6/1kv ABC Cable Caai Overhead Transmission Line Low Voltage Aerial Bundle ABC Cable
NFC Medium Voltage Mv 11kv 22kv 33kv Aluminum XLPE Insulated Overhead ABC Aerial Bundled Power Cable
Popular HENAN UME CABLE CO. Products
No Sheathed Stranded Conductor Overhead Transmission Line Bare Copper Conductor
Service Drop Cable Neutral Messenger AAAC Triplex Cable 6AWG Hippa
Popular Ltd. Products
Thhn Electrical Wire Nylon Wire Electrical Cable Wire 1.5mm 2.5mm 4mm 6mm 10mm
Aluminum Alloy Cables Class 2 Copper Conductor PVC/XLPE/ Peconcentric Cables
Hot Sale 1X95mm2 Single Core ABC Cable Al XLPE Cable
Rvv H05VV-F Cable Multicore 1.5mm 2.5mm Flexible Cable Copper Wire
Hot Flat Cord Twin Solid Copper Conductor PVC House Electric Cable Wire
Tags: ABC Cable Triplex Service Drop Cable, Aerial Bundled Cable, HENAN UME CABLE CO., Ltd.