Low Voltage Two Cores 4mm2 10mm2 16mm2 PVC Insulated and Jacket Copper VV Energy Industry Cable

China Low Voltage Two Cores 4mm2 10mm2 16mm2 PVC Insulated and Jacket Copper VV Energy Industry Cable  manufacture and supplier

Low Voltage Two Cores 4mm2 10mm2 16mm2 PVC Insulated and Jacket Copper VV Energy Industry Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
ZRYJV22
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjv22
Brand
Guowang
Operating Temperature
Max 90°c
Ambient Temperature
Not Be Lower Than -10ºC
Laying Temperature
Not Be Lower Than 0ºC
Bending Radius
15×overall Diameter
Transport Package
Iron Drum Packing
Specification
As per the customer request
Trademark
GUOWANG
Origin
China
HS Code
8544492100
Production Capacity
500000/Week

Packaging & Delivery

Package Size
2100.00cm * 1100.00cm * 1050.00cm
Package Gross Weight
200.000kg

Product Description

 

Detailed Photos

Product Description

System
This product is suitable for AC 50Hz, rated voltage 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/30KV, 21/35KV, 26/35kV distribution network or industrial installations in the fixed laying.
Occasion
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution.  For example, can be used in power distribution and other places within industrial and mining enterprises.
Features
It has the characteristics of high normal operation temperature of conductor, simple structure, convenient use, and not limited by laying drop.
This product uses double-steel tape armoured, can withstand greater mechanical pressure.
Implementation Standards
GB/T 12706-2020 Extruded insulated power cables and accessories with rated voltages 1kV (Um=1.2kV) to 35kV (Um=40.5kV)
Usage features
Rated voltage
The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/15kV, and the maximum voltage of the AC system should not exceed 17.5kV.
The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.
The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.
The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously the time does not exceed 5s.
Ambient Temperature
The minimum ambient temperature for cable operation is -10°C.
Laying Temperature
During installation and laying, the temperature should not be lower than 0ºC.
Bending Radius
When the single-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 20D. When the single-core cable is armored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is armored, the recommended minimum bending radius of the cable during installation is 12D. Note: D is the outer diameter of the cable.
Product Identification
Cores of Cable Wire
Color mark 1 core: omit  3 core: red, yellow, green (plus color tape)
Sheath
The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer’s name, product model, rated voltage, and the manufacturer’s name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete mark and the beginning of the next mark: should not exceed 500mm on the cable outer sheath; The cable insulation or tape should not exceed 200mm.Printed signs should be rub resistant and not easy to fall off, and the print on the surface should be legible.
Note: The mark on the surface of the sheath can also add other content according
to the custom of the user or the manufacturer.
Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils, if there is no agreement, the delivery length is not less than 100 meters.   Delivery of short sections of cable not less than 20 meters in length is permitted, the quantity of which does not exceed 10% of the total length of delivery, or any length of cable may be delivered according to mutual agreement.
Length Error
The measurement error of delivery length is ±0.5%.

Product Parameters
Rated Voltage No. of CORES CORSS SECTIONAL(MM2) CONDUCTOR CORE DIAMETER (MM) CONDUCTOR SHIELD THICKNESS(MM) INSULATION THICKNESS(MM) NON METAL SHIELD SPEC. (MM) METAL SHIELD SPEC. (MM) BELT (MM) INNER SHEATH THICKNESS(MM) ARMOURED SPEC. (MM) JACKET THICKNESS (MM) OVERALL DIAMETER (MM) WEIGHT (KG/KM)
3.6/6KV 3 25 7/2.18 6 0.8 2.5 0.7 30×0.10 60×0.20 1.2 35×0.5 2.2 40.2 2501.5
3 3×35 7/2.58 7 0.8 2.5 0.7 30×0.10 60×0.20 1.3 40×0.5 2.3 42.8 2948.9
3 3×50 10/2.58 8.4 0.8 2.5 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46 3540.7
3 3×70 19/2.18 10 0.8 2.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 4340
3 3×95 19/2.58 11.6 0.8 2.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 53.5 5305.7
3 3×120 24/2.58 13 0.8 2.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.1 6261.2
3 3×150 30/2.58 14.6 0.8 2.5 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 60.9 7364.4
3 3×185 37/2.58 16.2 0.8 2.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 64.6 8581.2
3 3×240 48/2.58 18.5 0.8 2.6 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.6 10567.3
3 3×300 60/2.58 20.6 0.8 2.8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.4 76.5 12727.7
3 3×400 61/2.94 23.8 0.8 3 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.5 16926.8
6/6KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 1.3 40×0.5 2.4 44.7 2874.3
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46.8 3290.8
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 1.4 45×0.5 2.6 50.4 3949
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 1.5 50×0.5 2.7 54.3 4777.7
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.9 5763.8
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 61.4 6720.3
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 3 65 7815.6
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68.9 9086.8
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.4 11054
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.5 13136.9
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 2 60×0.8 3.7 88.2 17185.7
6/10KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 1.3 40×0.5 2.4 44.7 2874.3
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46.8 3290.8
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 1.4 45×0.5 2.6 50.4 3949
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 1.5 50×0.5 2.7 54.3 4777.7
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.9 5763.8
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 61.4 6720.3
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 3 65 7815.6
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68.9 9086.8
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.4 11054
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.5 13136.9
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 2 60×0.8 3.7 88.2 17185.7
8.7/10KV 3 3×25 7/2.18 6 0.8 4.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 3330.9
3 3×35 7/2.58 7 0.8 4.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 52.2 3789.7
3 3×50 10/2.58 8.4 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.7 55.6 4452.4
3 3×70 19/2.18 10 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 59.2 5276.9
3 3×95 19/2.58 11.6 0.8 4.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 63.3 6351.4
3 3×120 24/2.58 13 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 66.7 7331.5
3 3×150 30/2.58 14.6 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.3 8454.9
3 3×185 37/2.58 16.2 0.8 4.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.2 9756.8
3 3×240 48/2.58 18.5 0.8 4.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.7 11768.1
3 3×300 60/2.58 20.6 0.8 4.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.1 14708.5
3 3×400 61/2.94 23.8 0.8 4.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.6 18055.8
8.7/15KV 3 3×25 7/2.18 6 0.8 4.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 3330.9
3 3×35 7/2.58 7 0.8 4.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 52.2 3789.7
3 3×50 10/2.58 8.4 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.7 55.6 4452.4
3 3×70 19/2.18 10 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 59.2 5276.9
3 3×95 19/2.58 11.6 0.8 4.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 63.3 6351.4
3 3×120 24/2.58 13 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 66.7 7331.5
3 3×150 30/2.58 14.6 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.3 8454.9
3 3×185 37/2.58 16.2 0.8 4.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.2 9756.8
3 3×240 48/2.58 18.5 0.8 4.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.7 11768.1
3 3×300 60/2.58 20.6 0.8 4.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.1 14708.5
3 3×400 61/2.94 23.8 0.8 4.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.6 18055.8
12/20KV 3 3×35 7/2.58 7 0.8 5.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.1 4285.4
3 3×50 10/2.58 8.4 0.8 5.5 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 60.5 4973.4
3 3×70 19/2.18 10 0.8 5.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 64.1 5823.8
3 3×95 19/2.58 11.6 0.8 5.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68 6897.9
3 3×120 24/2.58 13 0.8 5.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.2 71.4 7901.8
3 3×150 30/2.58 14.6 0.8 5.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 75.1 9053.5
3 3×185 37/2.58 16.2 0.8 5.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.1 10413.9
3 3×240 48/2.58 18.5 0.8 5.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 85.9 13280.5
3 3×300 60/2.58 20.6 0.8 5.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.8 90.8 15449.8
3 3×400 61/2.94 23.8 0.8 5.5 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 98.5 18892.9
18/30KV 3 3×50 10/2.58 8.4 0.8 8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 72.5 6386.5
3 3×70 19/2.18 10 0.8 8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.4 76.1 7299.4
3 3×95 19/2.58 11.6 0.8 8 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 80 8441.8
3 3×120 24/2.58 13 0.8 8 0.7 40×0.10 60×0.20 2 60×0.8 3.7 84.8 10343.6
3 3×150 30/2.58 14.6 0.8 8 0.7 40×0.10 60×0.20 2 60×0.8 3.8 88.4 11590.4
3 3×185 37/2.58 16.2 0.8 8 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 92.3 13027
3 3×240 48/2.58 18.5 0.8 8 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 97.8 15230.4
3 3×300 60/2.58 20.6 0.8 8 0.7 40×0.10 60×0.20 2.3 60×0.8 4.2 102.7 17485.5
3 3×400 61/2.94 23.8 0.8 8 0.7 40×0.10 60×0.20 2.4 60×0.8 4.5 110.4 21064.6
21/35KV 3 3×50 10/2.58 8.4 0.8 9.3 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 78.7 7199.8
3 3×70 19/2.18 10 0.8 9.3 0.7 40×0.10 60×0.20 2 60×0.8 3.6 83.7 8974.4
3 3×95 19/2.58 11.6 0.8 9.3 0.7 40×0.10 60×0.20 2 60×0.8 3.8 87.6 10187.9
3 3×120 24/2.58 13 0.8 9.3 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 91 11318.7
3 3×150 30/2.58 14.6 0.8 9.3 0.7 40×0.10 60×0.20 2.2 60×0.8 4 94.8 12644.9
3 3×185 37/2.58 16.2 0.8 9.3 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 98.5 14069.7
3 3×240 48/2.58 18.5 0.8 9.3 0.7 40×0.10 60×0.20 2.3 60×0.8 4.3 104 16323.9
3 3×300 60/2.58 20.6 0.8 9.3 0.7 40×0.10 60×0.20 2.4 60×0.8 4.4 108.9 18623.5
3 3×400 61/2.94 23.8 0.8 9.3 0.7 40×0.10 60×0.20 2.5 60×0.8 4.7 116.6 22273
26/35KV 3 3×50 10/2.58 8.4 0.8 10.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 85.6 8813.9
3 3×70 19/2.18 10 0.8 10.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.8 89.5 9874.4
3 3×95 19/2.58 11.6 0.8 10.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.1 11072.9
3 3×120 24/2.58 13 0.8 10.5 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 96.7 12275.5
3 3×150 30/2.58 14.6 0.8 10.5 0.7 40×0.10 60×0.20 2.3 60×0.8 4.2 100.6 13640.3
3 3×185 37/2.58 16.2 0.8 10.5 0.7 40×0.10 60×0.20 2.3 60×0.8 4.3 104.2 15089.6
3 3×240 48/2.58 18.5 0.8 10.5 0.7 40×0.10 60×0.20 2.4 60×0.8 4.5 109.8 17397.2
3 3×300 60/2.58 20.6 0.8 10.5 0.7 40×0.10 60×0.20 2.5 60×0.8 4.6 114.7 19738.2
3 3×400 61/2.94 23.8 0.8 10.5 0.7 40×0.10 60×0.20 2.6 60×0.8 4.9 122.4 23453.6
Company Profile

Packaging & Shipping

Exihibition

 

Certifications

FAQ

We are China Low Voltage Two Cores 4mm2 10mm2 16mm2 PVC Insulated and Jacket Copper VV Energy Industry Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Armoured Copper Cable Products

Factory Price Yjv22 6mm 0.6/1kv LV XLPE Power Turkey Insulated Cables Standard Wire Cable 3*6+1*4 2 3 4 5 Core

Popular Henan Guowang Cable Group Co. Products

Copper Cable Solid 95mm 4 Core ISO Standard 0.6/1kv Low Voltage XLPE Power Cable

0.6/35kv Sta Swa Awa Multi Core Copper/ Aluminum Conductor XLPE Insulated PVC Sheathed Power Cable Electric Cable

N2xy/N2xcy/Yjv22 4*300+1*150mm2 Sta Construction Industrial LSZH XLPE Insulated PVC Sheathed Rigid Copper Conductor Fire Resistant Electric Power Cable

PVC XLPE Guowang 4/0 Slippery Rock Aluminum Aerial Bundle Cable

CE Approved Rubber PVC Flexible Copper Wire 450V 750V Cable

Flexible Copper Conductor PVC Insulation PVC Jacket Control Cable

Popular Ltd. Products

Wholesale RG6 Coaxial Cable RG6 for CCTV Camera Electric Wire Coaxial Cable Rg-6/U

Computer PVC Guowang Pallet/According to Your Need Copper Braid Shielding Electric Cable

Electrical Cable for African Country Used Overhead Cable

Medium Voltage Electrical Copper/Aluminum Conductor XLPE Insulated Power Cable

R- (N) Tscgewou 3.6/6 to 18/30 Kv 3X50+3X25/3 3X70+3X50/3 3X95+3X50/3 3X120+3X70/3 3X150+3X70/3

H01n2-D H01n2-E Electric Welding Cable Wire 10mm2 16mm2

Popular XLPE Insulation Armored Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION