IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core)

IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core) image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
IEC 60502 Type Cable
0.6/1 kV CVV-SWA
IEC 60502 (2-30 core)
Application : For use in duct, tray and for direct burying in ground. The cable subject to immerce in water all the
line.
Conductor : Concentric Stranded annealed copper wire
Insulation : PVC Black color
Identification : Printed White number on the surface of Black insulation
Filler : Suitable filler
Binding tape : Suitable tape
Inner sheath : PVC Black color
Armour : Galvanized steel wire
Binding tape : Suitable tape
Outher Sheath : PVC Black color
2 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thickn ess of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
2 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 36.0 | 0.0162 | 320 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 24.5 | 0.0142 | 345 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 16.0 | 18.1 | 0.0135 | 350 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 12.1 | 0.0115 | 390 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 0.80 | 1.8 | 17.5 | 7.41 | 0.0093 | 460 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 21.0 | 4.61 | 0.0092 | 710 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 22.0 | 3.08 | 0.0078 | 820 | 500/D |
3 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 15.5 | 36.0 | 0.0162 | 365 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 16.0 | 24.5 | 0.0142 | 370 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 18.1 | 0.0135 | 385 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 12.1 | 0.0115 | 430 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 7.41 | 0.0093 | 635 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 21.5 | 4.61 | 0.0092 | 800 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 23.0 | 3.08 | 0.0078 | 935 | 500/D |
4 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm | No.&dia.of wires No./mm | Thickness of insulation mm | Thickness of inner sheath mm | Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at 20C) Ohm/km |
Minimum insulation resistance (at 70C) Ohm/km |
Cable weight (Approx.) kg/km |
Stan dard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 16.5 | 36.0 | 0.0162 | 380 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 24.5 | 0.0142 | 410 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 18.1 | 0.0135 | 425 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 12.1 | 0.0115 | 480 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 7.41 | 0.0093 | 715 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 23.0 | 4.61 | 0.0092 | 915 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.25 | 1.8 | 24.5 | 3.08 | 0.0078 | 1075 | 500/D |
5 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 17.0 | 36.0 | 0.0162 | 420 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 24.5 | 0.0142 | 455 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 19.0 | 18.1 | 0.0135 | 595 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 12.1 | 0.0115 | 665 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 21.5 | 7.41 | 0.0093 | 805 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.25 | 1.8 | 24.5 | 4.61 | 0.0092 | 1040 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 27.0 | 3.08 | 0.0078 | 1385 | 500/D |
6 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thic kness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 36.0 | 0.0162 | 450 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 18.1 | 0.0135 | 635 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 12.1 | 0.0115 | 715 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 7.41 | 0.0093 | 870 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 26.5 | 4.61 | 0.0092 | 1270 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 28.5 | 3.08 | 0.0078 | 1515 | 500/D |
7 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thickn ess of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.2 | 0.80 | 1.8 | 18.0 | 36.0 | 0.0162 | 455 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 19.5 | 24.5 | 0.0142 | 620 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 18.1 | 0.0135 | 650 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 12.1 | 0.0115 | 730 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 7.41 | 0.0093 | 895 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 26.5 | 4.61 | 0.0092 | 1315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 28.5 | 3.08 | 0.0078 | 1580 | 500/D |
Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 20.0 | 36.0 | 0.0162 | 625 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 24.5 | 0.0142 | 680 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 21.0 | 18.1 | 0.0135 | 710 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 12.1 | 0.0115 | 810 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 7.41 | 0.0093 | 995 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 28.0 | 4.61 | 0.0092 | 1470 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.8 | 30.0 | 3.08 | 0.0078 | 1770 | 500/D |
9 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 36.0 | 0.0162 | 680 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 21.5 | 24.5 | 0.0142 | 750 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 18.1 | 0.0135 | 770 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 12.1 | 0.0115 | 885 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 26.0 | 7.41 | 0.0093 | 1230 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.8 | 29.5 | 4.61 | 0.0092 | 1630 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 1.9 | 32.0 | 3.08 | 0.0078 | 1975 | 500/D |
10 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 725 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 22.5 | 24.5 | 0.0142 | 800 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 18.1 | 0.0135 | 835 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 12.1 | 0.0115 | 955 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 7.41 | 0.0093 | 1385 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.0 | 4.61 | 0.0092 | 1775 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 24.5 | 3.08 | 0.0078 | 2170 | 500/D |
11 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
11 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 765 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 24.5 | 0.0142 | 840 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 18.1 | 0.0135 | 880 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 12.1 | 0.0115 | 1150 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 28.0 | 7.41 | 0.0093 | 1415 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.5 | 4.61 | 0.0092 | 1905 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 3.08 | 0.0078 | 2310 | 500/D |
12 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
12 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 22.0 | 36.0 | 0.0162 | 765 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 24.5 | 0.0142 | 845 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 18.1 | 0.0135 | 885 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 12.1 | 0.0115 | 1160 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 28.0 | 7.41 | 0.0093 | 1435 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 32.5 | 4.61 | 0.0092 | 1940 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 3.08 | 0.0078 | 2365 | 500/D |
13 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
13 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 36.0 | 0.0162 | 820 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 24.5 | 0.0142 | 905 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 18.1 | 0.0135 | 950 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 12.1 | 0.0115 | 1230 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 29.0 | 7.41 | 0.0093 | 1545 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 34.0 | 4.61 | 0.0092 | 2085 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.1 | 38.0 | 3.08 | 0.0078 | 2820 | 500/D |
14 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thic kness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stan dard Length m |
14 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.0 | 36.0 | 0.0162 | 825 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.25 | 1.8 | 24.0 | 24.5 | 0.0142 | 915 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.25 | 1.8 | 24.5 | 18.1 | 0.0135 | 955 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 12.1 | 0.0115 | 1240 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 29.0 | 7.41 | 0.0093 | 1565 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 1.9 | 34.0 | 4.61 | 0.0092 | 2120 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 1.60 | 2.1 | 38.0 | 3.08 | 0.0078 | 2570 | 500/D |
15 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm |
No.&dia. of wires No./mm |
Thickness of insulation mm |
Thickness of inner sheath mm |
Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km | Stand ard Length m |
15 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 36.0 | 0.0162 | 880 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 24.5 | 0.0142 | 1115 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.60 | 1.8 | 26.0 | 18.1 | 0.0135 | 1150 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 12.1 | 0.0115 | 1330 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 30.0 | 7.41 | 0.0093 | 1675 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 4.61 | 0.0092 | 2305 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 2.00 | 2.1 | 39.5 | 3.08 | 0.0078 | 3085 | 500/D |
16 Core CVV-SWA Control Cable
No.of core | Nominal cross-sectional area sq.mm | No.&dia.of wires No./mm | Thickness of insulation mm | Thickness of inner sheath mm | Diameter of steel wire armour mm |
Thick ness of outer sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at 20C) Ohm/km |
Minimum insulation resistance (at 70C) Ohm/km |
Cable weight (Approx.) kg/km |
Stan dard Length m |
16 | 0.5 | 7/0.30 | 0.8 | 1.2 | 1.25 | 1.8 | 23.5 | 36.0 | 0.0162 | 885 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.2 | 1.60 | 1.8 | 25.5 | 24.5 | 0.0142 | 1225 | 500/D | |
1 | 7/0.40 | 0.8 | 1.2 | 1.60 | 1.8 | 26.5 | 18.1 | 0.0135 | 1160 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.2 | 1.60 | 1.8 | 27.5 | 12.1 | 0.0115 | 1345 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.60 | 1.8 | 30.0 | 7.41 | 0.0093 | 1700 | 500/D | |
4 | 7/0.85 | 1.0 | 1.2 | 1.60 | 2.0 | 35.5 | 4.61 | 0.0092 | 2340 | 500/D | |
6 | 7/1.04 | 1.0 | 1.2 | 2.00 | 2.1 | 39.5 | 3.08 | 0.0078 | 3135 | 500/D |
The table of 0.6/1 KV CVV-SWA shown concentric stranded conductor only
If you want to have solid or flexible conductor type, please contact with our Sales Department.
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China IEC 60502 Type Cable0.6/1 Kv Cvv-Swaiec 60502 (2-30 core) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 2464 Control Cable Products
Aluminium Concentric BS 7870 Hffr Insulation Cable
Aluminium Concentric BS Standard 7870 PVC Cable
Extra-Flexible Copper Conductor XLPE Insulation and Lsf Jacket Control Cable
VDE Standard Control Cablepur-Cy Control Cables
Italian Standard Control Cable Fg7r
British Standard Control Cable H05vvf
Popular 4mm2 Control Cable Products
VDE Standard Control Cablepur-Cy Control Cables
VDE Standard Control Cableliycy PVC/Tcwb/PVC Control Cable
Aluminium Concentric BS 7870 Low Somke Zero Halogen Cable
British Standard Control Cable H05vvf
Italian Standard Control Cable Fg7m1
BS British Standard Control Cable
Popular HENAN BAOFENG CABLE CO. Products
ACSR Conductor Price List 400mm2 Bare Conductor Sizes
All Aluminium Straneded Conductor AAC
Bare Overhead Aluminum Conductor Steel Reinforced AAC ACSR Mango Conductor
0.6/1kv 1X25+25mm2 Aluminum AAC Conductor XLPE Insulation Caai Cable
PE XLPE Insulated Overhead Aluminum Conductor ABC Cable Power
IEC ASTM 0.6/1kv Customized ABC XLPE Insulated Aluminum/Copper Aerial Bundle Cable
Popular Ltd. Products
Medium Voltage Spacer Overhead Insulated Line Aluminum Aerial Bundle Cable ABC Electric Cable
UL3069 Flexible Tin Copper Silicone Fiberglass Rubber Braided Insulation Electric Wire
DC PV Copper Power Twin Double Dual 2*2.5mm2 2*4mm2 2*10mm2 Solar Cable Solar Kabel
Oxygen-Free Aluminum 25 35 50 70 mm Conductor ABC Cable Manufacturer
Tags: 2464 Control Cable, 4mm2 Control Cable, HENAN BAOFENG CABLE CO., Ltd.