High Temperature Resistance 0.6/1kv Nh-Yjlv Wdz Aluminum Conductor XLPE Insulated Fire Resistant Power Electric Cable

China High Temperature Resistance 0.6/1kv Nh-Yjlv Wdz Aluminum Conductor XLPE Insulated Fire Resistant Power Electric Cable  manufacture and supplier

High Temperature Resistance 0.6/1kv Nh-Yjlv Wdz Aluminum Conductor XLPE Insulated Fire Resistant Power Electric Cable image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
wdzyjlv
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjlv
Brand
Guowang
Operating Temperature
Max 90°c
Ambient Temperature
Not Be Lower Than -10ºC
Laying Temperature
Not Be Lower Than 0ºC
Bending Radius
20d
Transport Package
Iron Tray Packing
Specification
As per the customer request
Trademark
GUOWANG
Origin
China
HS Code
8544492100
Production Capacity
500000/Week

Packaging & Delivery

Package Size
2100.00cm * 1100.00cm * 1050.00cm
Package Gross Weight
200.000kg

Product Description

Detailed Photos

Product Description

Scope of application
System    
This product is suitable for transmitting electric energy in power lines with AC 50Hz and rated voltage 0.6/1kV (system maximum voltage 1.2kV).
Occasion
Fixed laying in metallurgy, electric power, construction and other industries indoors, cable trenches, pipelines, direct burial and other places that do not need to withstand mechanical external force.
Features
The raw materials for product production are widely sourced and cheap, and are easy to process and manufacture.
The product is insulated with cross-linked polyethylene. Compared with PVC insulated cables, it has better insulation performance and canwithstand extremely high working temperatures, up to 90 degrees.
Standards compliant
Implementation standards
GB/T 12706.1-2020 Extruded insulated power cables and accessories with rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV ) )cable
additional standards
Usage features
Rated voltage
The rated voltage of power frequency AC is 0.6/1kV, and the maximum voltage of the AC system should not exceed 1.2kV.
Operating temperature
The maximum allowable long-term operating temperature of the cable conductor is 90°C; during a short circuit, the maximum temperature of the cable conductor does not exceed 250°C and the duration does not exceed 5 seconds.
ambient temperature
Minimum working environment temperature -15ºC.
Laying temperature
The laying temperature of cables should not be lower than 0ºC.
radius bend
The bending radius of single-core cables should be no less than 20 times the outer diameter of the cable, and the bending radius of multi-core cables should be no less than 15 times the outer diameter of the cable.
Product Identification
Core
1.Color identification When multi-core cables are marked with different colors, they must comply with the following regulations: 2-core cable: red, blue; 3-core cable:
yellow, green, red; 4-core cable: yellow, green, red, blue; 5-core cable Cable: yellow, green, red, blue, black (or determined by negotiation between the supplier and the buyer). The colors red, yellow and green are used for the main wire core. Blue is used for the neutral core. In order to avoid confusion with other colors, it is recommended to use light blue.
2. Digital identification When multi-core cables use digital identification, they must comply with the following regulations: 2-core cable: 0, 1; 3-core cable: 1, 2, 3; 4-core cable: 0, 1, 2, 3; 5-core cable :0,1,2,3,4. The numbers 1, 2, and 3 are used for the main core, and 0 is used for the neutral core. In a 5-core cable, the number “4” refers to the specific purpose conductor (including the grounding conductor). When the insulated cores are marked with numbers, the insulation should be of the same color and arranged according to the numbers. Numbers should be printed on the surface of the insulated core with Arabic numerals. The color of the numbers should be the same and have obvious contrast with the insulation color and the writing should be clear; the number signs should be repeated at equal intervals along the insulated core, and two adjacent sets of number signs should be Invert each other. When the logo consists of a single number, a dash should be placed below the number. If the The logo consists of two numbers, it should be arranged up and down and a dash should be placed below the subsequent numbers. The spacing between two adjacent sets of digital logos is d. Should be no larger than 50mm.
outer cortex
The outer sheath of the cable is usually black, but it can also be in colors other than black according to the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have continuous identification of the manufacturer’s name, product model and rated voltage . The manufacturer’s name identification can be Duplicate identification of manufacturer or trademark. The printed logo should be scratch-resistant and not fall off, and the printed content on the surface should be clearly legible. Note: The logo on the surface of the sheath can also add other logo contents according to the habits of the user or manufacturer.
Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils, and the delivery length of short-segment cables should not exceed 5% of the total delivery length, or cables of any length can be delivered according to mutual agreement.
Length error
Delivery length measurement error is ±0.5%
 

Product Parameters
Rated
voltage
No,of
CORES
core ×cross secticn
(MM)
CONDUCTOR CORE DIANETER
(MM2)
INSULATION
THCKNESS
(MM)
BELT
(MM)
JACKET
THICKNESS
(MM)
Reference outer diameter
(MM)
Reference weight
(kg/km)
DC
RESISTANCE
 (Ω/KM)
0.6/1KV 1 1×10 7/1.35 4.05 0.7 20×0.20 1.4 8.9 152.7 1.83
1 1×16 7/1.66 4.98 0.7 20×0.20 1.4 9.9 208.2 1.15
1 1×25 7/2.14 6.42 0.9 20×0.20 1.4 11.6 318.3 0.727
1 1×35 7/2.52 7.56 0.9 20×0.20 1.4 12.8 418 0.524
1 1×50 10/2.52 8.4 1 25×0.20 1.4 13.8 544 0.387
1 1×70 14/2.52 10 1.1 30×0.20 1.4 15.6 736.7 0.268
1 1×95 19/2.52 11.6 1.1 35×0.20 1.5 17.4 987.8 0.193
1 1×120 24/2.52 13 1.2 40×0.20 1.5 19 1226.7 0.153
1 1×150 30/2.52 14.6 1.4 45×0.20 1.6 21.2 1522.6 0.124
1 1×185 37/2.52 16.2 1.6 50×0.20 1.6 23.2 1860 0.0991
1 1×240 48/2.52 18.5 1.7 55×0.20 1.7 25.9 2386.3 0.0754
1 1×300 61/2.52 20.6 1.8 60×0.20 1.8 28.4 3000.1 0.0601
1 1×400 61/2.94 23.3 2 60×0.20 1.9 32.2 3870 0.047
1 1×500 60/3.29 26.6 2.2 60×0.20 2 35.6 4951 0.0366
1 1×630 60/3.69 29.6 2.4 60×0.20 2.2 39.4 6204.5 0.0283
Company Profile

Packaging & Shipping

Exihibition

Certifications

FAQ

We are China High Temperature Resistance 0.6/1kv Nh-Yjlv Wdz Aluminum Conductor XLPE Insulated Fire Resistant Power Electric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Henan Guowang Cable Group Co. Products

450/750V Copper Strip Shield Swa Copper Conductor Control Cable Solid Conductor PVC Insulted PVC Sheathed Power Cable

33kv 1*240mm2 3*240mm2 Swa/Awa Armoured Power Cable for Industry

20-650mm2 360mm2 520mm2 580mm2 650mm2 465mm2 AAAC Conductor Cables with High Quality

0.6/1kv Aluminum Conductor XLPE Insulated PVC Sheath Vlv Yjv Yjlv Cable

Stranded/Flexible Power Station High Quality Copper Armour Ug Cable Hot Yjv32, Yjv22

Cable Manufacturer Best Quality of Nyy, N2xy, Ymvk, Xvb-F2, U-1000 R2V Copper Cable 3X1.5mm2 3X2.5mm2 3G1.5mm2 3G2.5mm2

Popular Ltd. Products

Bare Aluminum Conductor E ASTM B232 BS215-2 IEC 61089 ACSR 150/25 mm2 DIN 48204 Standard ACSR Overhead Cable

Factory Price Thwn Thhn Cable Wire Size AWG Standard Stranded Copper Nylon Wire 1/0AWG 2/0AWG

Mining Cable Use in Industry Coal Mine Mobile Rubber Cable Flame Retardant Explosion-Proof Cable

110V AC Power Cord Japan Plug with Ground Wire

Yjlhvs2 XLPE/PVC Self-Locking Armored Aluminum Alloy Cable

Overhead CCS Copper Clad Steel Strand Cable Bare Conductor

Popular Nh-Yjlv Wdz Cable Products

  • No related articles
  • Popular Single Core Products

    Single Core Yjlv XLPE Insualted Power Cable Electric Wire Cable

    Copper Conductor Service Drop Wire Overhead XLPE Insulated Cable with Jkyj 1kv Aerial Bundle Cable

    Single Core Copper Conductor PVC Insulated 450/750V RV Electrical Wire Power Cable

    Single Core 18/30kv Medium Voltage Aluminium Tape Armoured Cable

    Single Core AAC Cable Electric Transmission

    Single Core 19/33kv Medium Voltage Unarmoured Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION