Factory Price Aluminum Cable 70mm2 95mm2 AAC Conductor Cable

Factory Price Aluminum Cable 70mm2 95mm2 AAC Conductor Cable image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
Factory Price Aluminum Cable 70mm2 95mm2 Aac Conductor Cable
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
IEC 61089 | ||||||
Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
mm2 | No./mm | mm | kg/km | KN | ohm/km | |
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B231/B 231M | |||||||
Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
BS 215 Part 1 | |||||||
Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
BS EN 50182 | ||||||
Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Factory Price Aluminum Cable 70mm2 95mm2 AAC Conductor Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Cable 95mm2 Products
Popular Factory Price Aluminum Cable 70mm2 Products
Popular Henan Kingyear Aluminum Industrial Co. Products
Hard Drawn Aluminum Conductor Hda Conductor 25mm 11kv
0.6/1kv Aluminum Conductor XLPE Insulated Concentric Netural Cable
2 X 1.5 mm Cable Fire Resistant Flexible / Solid Electrical Copper Cable PVC Cable Wire
0.6/1kv Cu/XLPE/Swa/PVC 4X35mm Armoured Power Cable
ASTM B232 All Aluminum Conuductor Steel Reinforced 477mcm ACSR Conductor
Popular Ltd. Products
Manufacture of AAC/ACSR/AAAC Aluminum Electrical Wire Bare Conductor Overhead Line
XLPE Insulated Aerial Bundle Overhead Aluminum Cable ABC Cable 2X25mm2
0.6/1kv ACSR Conductor XLPE Insulated Quadruplex Overhead Cable
Wholesale Copperweld Conductivity 15-70% Enamel Coated Copper Clad Steel Wire CCS
AAAC Overhead Bare Conductors All Aluminum Alloy Conductor
Ahxcmk-Wtc Cables 3X50/35 Ahxcmk-Wtc 12/20 (24) Kv Axlj-F Tt Medium Voltage Power Cable
Tags: Aluminum Cable 95mm2, Factory Price Aluminum Cable 70mm2, Henan Kingyear Aluminum Industrial Co., Ltd.