Bare All Aluminium Conductor AAC Aster 2/0 AWG Size for Overhead Line

Bare All Aluminium Conductor AAC Aster 2/0 AWG Size for Overhead Line image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
2.Brief Description:
AAC conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).AAC CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %. The higher strengthAAC CONDUCTORS are used for river crossings, overhead ground wires, installations involving extra long spans etc.. Against any given resistance of conductor, AAC CONDUCTORS may be manufactured for having a wide range of tensile strength as per requirement. The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of AAC CONDUCTORS a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.
3.Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. AAC CONDUTOR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. AAC CONDUTORS are used extensively for overhead ground wires, river crossings etc. These AAC CONDUTORS are available with us in various types for meeting the exact requirements of the clients.
4. AAC all aluminum conductors strand.
IEC standard
Code Number | Area | Number of Wires | Diameter | Linear Mass | Rated Strength | Max.D.C.Resistence at 20ºC | |
mm2 | Wire | Cond. | kg/km | kN | Ω/km | ||
10 | 10 | 7 | 1.35 | 4.05 | 27.4 | 1.95 | 2.8633 |
16 | 16 | 7 | 1.71 | 5.12 | 43.8 | 3.04 | 1.7896 |
25 | 25 | 7 | 2.13 | 6.4 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7 | 2.7 | 8.09 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7 | 3.39 | 10.2 | 172.3 | 10.39 | 0.4545 |
100 | 100 | 19 | 2.59 | 12.9 | 274.8 | 17 | 0.2877 |
125 | 125 | 19 | 2.89 | 14.5 | 343.6 | 21.25 | 0.2302 |
160 | 160 | 19 | 3.27 | 16.4 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19 | 3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19 | 4.09 | 20.5 | 687.1 | 40 | 0.1151 |
315 | 315 | 37 | 3.29 | 23 | 867.9 | 51.97 | 0.0916 |
400 | 400 | 37 | 3.71 | 26 | 1102 | 64 | 0.0721 |
450 | 450 | 37 | 3.94 | 27.5 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37 | 4.15 | 29 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37 | 4.39 | 30.7 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61 | 3.63 | 32.6 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61 | 3.85 | 34.6 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61 | 4.09 | 36.8 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61 | 4.33 | 39 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61 | 4.57 | 41.1 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91 | 3.96 | 43.5 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91 | 4.18 | 46 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91 | 4.43 | 48.7 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91 | 4.58 | 50.4 | 4143.1 | 240 | 0.0193 |
BS 215
Code name | Nominal | Number | Cross- | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
( mm² ) | ( mm ) | ( mm² ) | ( mm ) | ( kg/km ) | daN | Ω/km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpilar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
ASTM B231
Code Name | Total Area | Stranding and wire diameter mm |
Linear Mass kg/km |
Overall Diameter mm |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/k |
|
AWG or MCM |
mm2 | ||||||
Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
Rose | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
Poppy | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
Peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
Syringa | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
Cosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
Mistletoe | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
Orchid | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
Flag | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
DIN 48201
Code Number | Caculated Area | Stranding and wire Diameter | Overall Diameter | Linear Mass | Calculated Breaking Load | Max D.C.Resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω,km |
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 |
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
35 | 34.36 | 7/2 50 | 7.5 | 94 | 585 | 0.8332 |
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 |
50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 |
70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 |
120 | 117 | 19/2.50 | 14 | 322 | 1910 | 0.2459 |
150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 |
185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 |
240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 |
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 |
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.07221 |
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.05781 |
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 |
500 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 |
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
We are China Bare All Aluminium Conductor AAC Aster 2/0 AWG Size for Overhead Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC 2/0AWG Products
Overhead Bare Conductor AAC 2/0AWG Aster
Popular AAC Aster Products
AAC Arbutus 402mm² 37/3.724 Bare All Aluminum Conductor ASTM B399
Popular Ltd. Products
Copper Core PE Insulated Copper Wire Braided Separately Shielded PVC Sheathed Computer
Low Voltage Cable 240mm 4core Stranded Copper Conductor XLPE Cable Prices
5-46kv 100% or 133% Tr-XLPE/LLDPE and Concentric Neutral Primary Ud Cable
Hi-Fi Speaker Cable Wire with 10 / 12 / 14 / 16 / 18 AWG
Popular Shanghai QIFAN Cable Co. Products
R- (N) TscgewÖ U Medium Voltage Rubber Flexible Cable for Reeling Applications
0.6/1 (1.2) Kv Low Voltage Al (Cu) /XLPE/PVC Two Core Copper/Aluminum XLPE Insulated Unarmored Cable
66kv Cu/XLPE/CAS/HDPE (PVC) Copper/Aluminum XLPE High Voltage Cable with Aluminium Corrugated Sheath
Extra High Voltage XLPE Cable 66kv 110kv 132kv 220kv 500kv Hv Power Cable
Tags: AAC 2/0AWG, AAC Aster, Ltd., Shanghai QIFAN Cable Co.