ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor

ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
IEC 61089 | ||||||
Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
mm2 | No./mm | mm | kg/km | KN | ohm/km | |
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B231/B 231M | |||||||
Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
BS 215 Part 1 | |||||||
Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
BS EN 50182 | ||||||
Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
We are China ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Cables Products
ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor
Overhead Transmisson Line All Aluminum Strand AAC Aluminum Cables
Overhead Line Conductor for Transmission
PVC XLPE Insulated Duplex, Triplex, Quadruplex Cable Overhead ABC Cable
33 Kv Three Core XLPE Insulated Aluminum Cables 3*50mm² Al/XLPE/Swa/PVC
ACSR/AAC/AAAC/ABC Cable Bare Aluminum Conductor All Aluminum Conductor Standard ASTM B231
Popular Cable Suppliers Products
Hot Bare Aluminum AAC AAAC ACSR ASTM B231overhead Aluminum Conductor Cable
ASTM B231 AAC AAAC ACSR Overhead Bare Aluminum Conductor
Popular Ltd. Products
Bare All Aluminum Conductor AAC Aphis 3/3.35 BS 215
Galvanized Steel Wire Rope Overhead Bare Condcutor
120mm Aluminium Conductor Bare Wire AAC Overhead Aluminum Cable
Popular Zhengzhou Zoom Link Cable Co. Products
China Manufacturer Hot Exporting Heat Resistant Bare Pure Electrical Copper Wire Spool
Goods in Stock AAC Conductor/AAC /ACSR/AAAC Aerial Bundled Electrical Cable Overhead Line Conductor
Copper Strand Wire Flexible PVC Insulated H05V-K/H07V-K
High Quality Aluminum Conductor Steel Core Power Cables ACSR 16mm2 800mm2 Overhead Cable
600/1000V Insulated Aluminum Cable Lxs 4X70+16
Galvanized Steel Wire Gsw 70 35 50 60 95 Gsw Wire
Tags: Aluminum Cables, Cable Suppliers, Ltd., Zhengzhou Zoom Link Cable Co.