Product Details

Model NO.
Yjv/Yjlv/Yjv22/Yjv32/Yjv62/Yjv72
Insulation
XLPE/PVC
Length
Lengths Customize
Conductor
Copper
Sample
Free
Transport Package
Standard Seaworthy Packing
Specification
1.5-300 mm2
Trademark
GUOWANG
Origin
China
HS Code
8544601290
Production Capacity
500km/Mouth

Packaging & Delivery

Package Size
200.00cm * 100.00cm * 200.00cm
Package Gross Weight
1500.000kg

Product Description

Product Description

 

System

This product is suitable for AC 50Hz, rated voltage 3.6/35KV distribution network or industrial installations in the fixed laying.

Occasion

It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution.  For example, can be used in power distribution and other places within industrial and mining enterprises.

Features

It has the characteristics of high normal operation temperature of conductor, simple structure, convenient use, and not limited by laying drop.

Standards Compliant

Implementation Standards

GB/T 12706-2020 Extruded insulated power cables and accessories with rated voltages 1kV (Um=1.2kV) to 35kV (Um=40.5kV)

Additional Standards

Usage features

Rated voltage

The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.

The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.

The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.

The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.

The rated voltage is 8.7/15kV, and the maximum voltage of the AC system should not exceed 17.5kV.

The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.

The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.

The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.

The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.

Operating temperature

The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously the time does not exceed 5s.

Ambient Temperature

The minimum ambient temperature for cable operation is -10°C.

Laying Temperature

During installation and laying, the temperature should not be lower than 0ºC.

Bending Radius

When the single-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 20D. When the single-core cable is armored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is armored, the recommended minimum bending radius of the cable during installation is 12D. Note: D is the outer diameter of the cable.

Cores of Cable Wire

Color mark 1 core: omit  3 core: red, yellow, green (plus color tape)

Sheath

The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer’s name, product model, rated voltage, and the manufacturer’s name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete mark and the beginning of the next mark: should not exceed 500mm on the cable outer sheath; The cable insulation or tape should not exceed 200mm. Printed signs should be rub resistant and not easy to fall off, and the print on the surface should be legible.

Note: The mark on the surface of the sheath can also add other content according to the custom of the user or the manufacturer.

Product Parameters
Rated Voltage No. of CORES CORSS SECTIONAL(MM2) CONDUCTOR CORE DIAMETER (MM) CONDUCTOR SHIELD THICKNESS(MM) INSULATION THICKNESS(MM) NON METAL SHIELD SPEC. (MM) METAL SHIELD SPEC. (MM) BELT (MM) JACKET THICKNESS (MM) OVERALL DIAMETER (MM) WEIGHT (KG/KM)
3.6/6KV 3 3×25 7/2.18 6 0.8 2.5 0.7 30×0.10 60×0.20 2.1 35.6 1674.8
3 3×35 7/2.58 7 0.8 2.5 0.7 30×0.10 60×0.20 2.1 37.8 2030.8
3 3×50 10/2.58 8.4 0.8 2.5 0.7 30×0.10 60×0.20 2.2 41 2549.1
3 3×70 19/2.18 10 0.8 2.5 0.7 30×0.10 60×0.20 2.4 44.8 3260.6
3 3×95 19/2.58 11.6 0.8 2.5 0.7 40×0.10 60×0.20 2.5 48.5 4141
3 3×120 24/2.58 13 0.8 2.5 0.7 40×0.10 60×0.20 2.6 51.7 4968.7
3 3×150 30/2.58 14.6 0.8 2.5 0.7 40×0.10 60×0.20 2.7 55.3 5955.5
3 3×185 37/2.58 16.2 0.8 2.5 0.7 40×0.10 60×0.20 2.8 59 7081.9
3 3×240 48/2.58 18.5 0.8 2.6 0.7 40×0.10 60×0.20 3 64.8 8892.8
3 3×300 60/2.58 20.6 0.8 2.8 0.7 40×0.10 60×0.20 3.2 70.5 10875.2
3 3×400 61/2.94 23.8 0.8 3 0.7 40×0.10 60×0.20 3.4 78.7 13928.6
6/6KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 2.2 39.7 1913.5
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 2.3 42 2299.2
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 2.4 45.2 2837.2
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 2.5 48.9 3551.8
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 2.6 52.5 4451.6
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 2.7 55.8 5298.8
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 2.8 59.4 6306.2
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 2.9 63.1 7453.3
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 3.1 68.4 9253.6
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 3.3 73.3 11175.4
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 3.5 80.6 14160.5
6/10KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 2.2 39.7 1913.5
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 2.3 42 2299.2
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 2.4 45.2 2837.2
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 2.5 48.9 3551.8
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 2.6 52.5 4451.6
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 2.7 55.8 5298.8
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 2.8 59.4 6306.2
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 2.9 63.1 7453.3
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 3.1 68.4 9253.6
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 3.3 73.3 11175.4
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 3.5 80.6 14160.5
Company Profile

 

Certifications

 

Packaging & Shipping

 

FAQ

 

 

We are China Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Henan Guowang Cable Group Co. Products

Nylon Sheathed Thhn&Thwn Electrical Electric Cable Thhn 12AWG 14AWG UL83

Good Price IEC Standard 10mm2 16mm2 25mm2 450mm2 All Aluminum Conductors AAC

0.6/1kv Copper Conductor Multicore PVC Insulated Power Cable Zra-Yjv Zrb-Yjv Zrc-Yjv

XLPE Insulated Multi Cores Cu/PVC XLPE/PVC Aluminum Conductor Copper Cable Insulated Steel Wire

IEC 60502 Standard 0.6/1kv Low Voltage Copper Conductor PVC Insulated PVC Sheathed Steel Tape Armour Sta Power Cable Cu Conductor Electrical Wire

Hennan Guowang UL Electric Wire Industrial and Agricultural Use Towline Fabricado En China Cable

Popular Ltd. Products

High Quality PVC Communication Connecting Wire Networking Cable Connection Cable PE Insulation Cable

High Voltage Overhead Acar Alloy Conductor 750mcm

20-650mm2 520mm2 580mm2 650mm2 IEC Standard 300mm2 AAAC Conductor Cables in China

All Aluminum AAC Transmission Line Electric Power Wire Cable 70mm2 Single Core Electric Wire Cable Round Bare Conductor

LV Aerial Bundle Cable (600/1000V) 3X35 AAC/XLPE+35mm AAAC

11kv 22kv 15kv 33kv 35kv 3 Core 95mm 120mm 150mm 185mm 240mm 300mm 400mm Medium Voltage Mv Underground 3-Core XLPE Kable Insulated Wire Cu Swa PVC Power Cable

Popular Power Cable Products

Steel Wire Armored Underground Cu/Al Conductor Aluminum XLPE/PVC Insulated Copper Cable

OEM Spilt Concentric Cable Airdac SNE Service Copper Cable with Communication Cores 0.6/1kV

Yjv / Yjv22 /Yjlv /Yjlv22 /Zr Yjv 0.6/1kv Cu/Al/XLPE/PVC/Swa/Sta Power Cable

Cuivre U1000 RO2V 2 X 10mm2 Copper Power Cable XLPE Insulated Cable

DC & AMP; AC Guowang 1*25, 1*30, 120/70, 500/45 Bare Cable Conductor with ISO

3*120 Sqmm H05rn-F/H07rn-F 450/750V Epr Pcp Oil Resistance Flexible Copper Conductor Rubber Cable

Popular Single Core Products

1kv Jklgyj Overhead XLPE Insulated Cable with Aluminum/Steel Conductor Aerial Bundle Cable Service Drop Wire

6/10kv Single Core Mv Aluminum Conductor XLPE Insulation PVC Sheath Power Cable

Overhead Insulated Service Drop Cable Aerial Bundle Cable Jklv 1kv Aluminum Conductor PVC Insulated Service Drop Wire

Sta Yjlv62 Single Core Mv Power Cable Aluminum Conductor Armoured XLPE Insulated PVC Sheathed

Single Core 6.35/11kv Medium Voltage Unarmoured Cable

500mm2 Single Core XLPE Cable with Copper Core RO2V Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION