500mm2 DIN 48201 All Aluminum Alloy Conductor AAAC

500mm2 DIN 48201 All Aluminum Alloy Conductor AAAC image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
Aerial Bundled Cables
Aluminium Conductor Cables
All Aluminum Alloy Conductor (AAAC) Cables
Application
AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is
also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Standard
Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201-6 standards
Construction
AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.
This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International
Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant
standard.
Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher trength
but lower conductivity than pure aluminium.
Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind
loadings are low.
Electrical Properties
Density@20ºC | 2.70 kg/dm |
Temperature Coefficient@20°C | 0.00360 (°C) |
Resistivity@20°C | 0.0326 Ohms mm²/m |
Linear Expansivity | 23 x10-6(°C) |
Service Conditions
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m² |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic Level | 10 – 18 |
Relative Humidity | 5 – 100% |
Construction Parameters
BS 3242
Code | AL Nominal Area | Cu Nominal Area Equivalent | Total Area | Stranding | Overall Diameter | Weight |
mm² | mm² | mm² | No.×mm | mm | kg/km | |
– | – | 6.45 | 11.7 | 7/1.47 | 4.41 | 32.2 |
Box | – | 9.68 | 18.8 | 7/1.85 | 5.55 | 51.7 |
Acacia | – | 12.9 | 21.9 | 7/2.08 | 6.24 | 66.1 |
Almond | 25 | 16.1 | 30.1 | 7/2.34 | 7.02 | 82.9 |
Ceda | 30 | 19.4 | 35.5 | 7/2.54 | 7.62 | 97.8 |
– | 40 | 22.6 | 42.2 | 7/2.77 | 8.31 | 116.4 |
Fir | 50 | 25.8 | 47.8 | 7/2.95 | 8.85 | 131.8 |
Hazel | 100 | 32.3 | 59.9 | 7/3.30 | 9.9 | 165 |
Pine | – | 38.7 | 71.7 | 7/3.61 | 10.83 | 197.7 |
– | – | 45.2 | 84.1 | 7/3.91 | 11.73 | 231.6 |
Willow | 150 | 48.4 | 89.8 | 7/4.04 | 12.12 | 247.5 |
– | 175 | 51.6 | 96.5 | 7/4.19 | 12.57 | 266.2 |
– | 300 | 58.1 | 108.8 | 7/4.45 | 13.35 | 299.8 |
Oak | – | 64.5 | 118.9 | 7/4.65 | 13.95 | 327.8 |
– | – | 80.6 | 118.8 | 19/2.82 | 14.1 | 327.6 |
Mulberry | – | 96.8 | 151.1 | 19/3.18 | 15.9 | 416.7 |
Ash | – | 113 | 180.7 | 19/3.48 | 17.4 | 498.1 |
Elm | – | 129 | 211 | 19/3.76 | 18.8 | 582.1 |
Poplar | – | 145 | 239 | 37/2.87 | 20.09 | 658.8 |
– | – | 161 | 270.8 | 37/3.05 | 21.35 | 746.7 |
Sycamore | – | 194 | 303 | 37/3.23 | 22.61 | 834.9 |
Upas | – | 226 | 362.1 | 37/3.53 | 24.71 | 998.6 |
– | – | 258 | 421.8 | 37/3.81 | 26.47 | 1163 |
Yew | – | – | 479.9 | 37/4.06 | 28.42 | 1323 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
BS EN 50182
Code | Stranding | Nominal Area | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
No.×mm | mm² | mm | kg/km | KN | Ω/Km | A | |
Box | 7/1.85 | 18.8 | 5.55 | 51.4 | 5.55 | 1.748 | 87 |
Acacia | 7/2.08 | 23.8 | 6.24 | 64.9 | 7.02 | 1.3828 | 101 |
Almond | 7/2.34 | 30.1 | 7.02 | 82.2 | 8.88 | 1.0926 | 116 |
Cedar | 7/2.54 | 35.5 | 7.62 | 96.8 | 10.46 | 0.9273 | 129 |
Deodar | 7/2.77 | 42.2 | 8.31 | 115.2 | 12.44 | 0.7797 | 143 |
Fir | 7/2.95 | 47.8 | 8.85 | 130.6 | 14.11 | 0.6875 | 155 |
Hazel | 7/3.30 | 59.9 | 9.9 | 163.4 | 17.66 | 0.5494 | 178 |
Pine | 7/3.61 | 71.6 | 10.83 | 195.6 | 21.14 | 0.4591 | 199 |
Holly | 7/3.91 | 84.1 | 11.73 | 229.5 | 24.79 | 0.3913 | 219 |
Willow | 7/4.04 | 89.7 | 12.12 | 245 | 26.47 | 0.3665 | 228 |
Oak | 7/4.65 | 118.9 | 13.95 | 324.5 | 35.07 | 0.2767 | 272 |
Mulberry | 19/3.18 | 150.9 | 15.9 | 414.3 | 44.52 | 0.2192 | 314 |
Ash | 19/3.48 | 180.7 | 17.4 | 496.1 | 53.31 | 0.183 | 351 |
Elm | 19/3.76 | 211 | 18.8 | 579.2 | 62.24 | 0.1568 | 386 |
Poplar | 37/2.87 | 239.4 | 20.09 | 659.4 | 70.61 | 0.1387 | 416 |
Sycamore | 37/3.23 | 303.2 | 22.61 | 835.2 | 89.4 | 0.1095 | 480 |
Upas | 37/3.53 | 362.1 | 24.71 | 997.5 | 106.82 | 0.0917 | 535 |
Yew | 37/4.06 | 479 | 28.42 | 1319.6 | 141.31 | 0.0693 | 633 |
Totara | 37/4.14 | 498.1 | 28.98 | 1372.1 | 146.93 | 0.0666 | 648 |
Rubus | 61/3.50 | 586.9 | 31.5 | 1622 | 173.13 | 0.0567 | 714 |
Sorbus | 61/3.71 | 659.4 | 33.39 | 1822.5 | 194.53 | 0.0505 | 764 |
Araucaria | 61/4.14 | 821.1 | 37.26 | 2269.4 | 242.24 | 0.0406 | 868 |
Redwood | 61/4.56 | 996.2 | 41.04 | 2753.2 | 293.88 | 0.0334 | 970 |
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
IEC 61089
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
mm² | No.×mm | mm | kg/km | KN | Ω/Km | A | |
16 | 18.4 | 18.4 | 5.49 | 50.4 | 5.43 | 1.7896 | 86 |
25 | 28.8 | 28.8 | 6.87 | 78.7 | 8.49 | 1.1453 | 113 |
40 | 46 | 46 | 8.67 | 125.9 | 13.58 | 0.7158 | 151 |
63 | 72.5 | 72.5 | 10.89 | 198.3 | 21.39 | 0.4545 | 200 |
100 | 115 | 115 | 13.9 | 316.3 | 33.95 | 0.2877 | 266 |
125 | 144 | 144 | 15.5 | 395.4 | 42.44 | 0.2302 | 305 |
160 | 184 | 184 | 17.55 | 506.1 | 54.32 | 0.1798 | 355 |
200 | 230 | 230 | 19.65 | 632.7 | 67.91 | 0.1439 | 407 |
250 | 288 | 288 | 21.95 | 790.8 | 84.88 | 0.1151 | 466 |
315 | 363 | 363 | 24.71 | 998.9 | 106.95 | 0.0916 | 535 |
400 | 460 | 460 | 27.86 | 1268.4 | 135.81 | 0.0721 | 618 |
450 | 518 | 518 | 29.54 | 1426.9 | 152.79 | 0.0641 | 663 |
500 | 575 | 575 | 31.15 | 1585.5 | 169.76 | 0.0577 | 706 |
560 | 645 | 645 | 33.03 | 1778.4 | 190.14 | 0.0516 | 755 |
630 | 725 | 725 | 35.01 | 2000.7 | 213.9 | 0.0458 | 809 |
710 | 817 | 817 | 37.17 | 2254.8 | 241.07 | 0.0407 | 866 |
800 | 921 | 921 | 39.42 | 2540.6 | 271.62 | 0.0361 | 928 |
900* | 1036 | 1036 | 41.91 | 2861.1 | 305.58 | 0.0321 | 992 |
1000* | 1151 | 1151 | 44.11 | 3179 | 339.53 | 0.0289 | 1051 |
1120* | 1289 | 1289 | 46.75 | 3560.5 | 380.27 | 0.0258 | 1118 |
1250* | 1439 | 1439 | 49.39 | 3973.7 | 424.41 | 0.0231 | 1185 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
ASTM B 399/B 399M
Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 |
4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 |
2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 |
0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 |
2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 |
3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 |
4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 |
250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 |
300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 |
350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 |
400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 |
450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 |
500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 |
550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 |
600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 |
650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 |
700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 |
750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 |
800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 |
900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 |
1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 |
1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 |
1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 |
1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
DIN 48201 Part 6
Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
Nominal | Teorical | ||||||
mm² | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
16 | 15.89 | 7/1.70 | 5.1 | 43 | 4.44 | 2.0742 | 78 |
25 | 24.25 | 7/2.10 | 6.3 | 66 | 6.77 | 1.3593 | 102 |
35 | 34.36 | 7/2.50 | 7.5 | 94 | 9.6 | 0.9591 | 126 |
50 | 49.48 | 7/3.00 | 9 | 135 | 13.82 | 0.666 | 158 |
50 | 48.35 | 19/1.80 | 9 | 133 | 13.5 | 0.6849 | 156 |
70 | 65.81 | 19/2.10 | 10.5 | 181 | 18.38 | 0.5032 | 189 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 26.05 | 0.3551 | 234 |
120 | 116.99 | 19/2.80 | 14 | 322 | 32.68 | 0.2831 | 269 |
150 | 147.11 | 37/2.25 | 15.8 | 406 | 41.09 | 0.2256 | 309 |
185 | 181.62 | 37/2.50 | 17.5 | 500 | 50.73 | 0.1828 | 352 |
240 | 242.54 | 61/2.25 | 20.3 | 670 | 67.74 | 0.1371 | 420 |
300 | 299.43 | 61/2.50 | 22.5 | 827 | 83.63 | 0.111 | 477 |
400 | 400.14 | 61/2.89 | 26 | 1104 | 111.76 | 0.0831 | 568 |
500 | 499.83 | 61/3.23 | 29.1 | 1379 | 139.6 | 0.0665 | 649 |
625* | 626.2 | 91/2.96 | 32.6 | 1732 | 174.9 | 0.0531 | 742 |
800* | 802.09 | 91/3.35 | 36.9 | 2218 | 224.02 | 0.0415 | 857 |
1000* | 999.71 | 91/3.74 | 41.1 | 2767 | 279.22 | 0.0333 | 971 |
* The items marked with “*” are not in our current product range and the details are for information only.
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Technical Data
Code | AL Nominal Area | Maximum Resistance DC at 20º | Current Rating | ||
Temperate | Tropical | ||||
mm² | Ω / km | Ω / 1000ft | Amp | Amp | |
– | – | 2.87 | 0.873 | 90 | 73 |
Box | – | 1.79 | 0.544 | 121 | 98 |
Acacia | – | 1.4 | 0.426 | 140 | 114 |
Almond | 25 | 1.11 | 0.339 | 162 | 131 |
Ceda | 30 | 0.944 | 0.288 | 180 | 145 |
– | 40 | 0.794 | 0.242 | 200 | 162 |
Fir | 50 | 0.7 | 0.213 | 217 | 175 |
Hazel | 100 | 0.559 | 0.17 | 250 | 201 |
Pine | – | 0.467 | 0.142 | 279 | 224 |
– | – | 0.398 | 0.121 | 309 | 247 |
Willow | 150 | 0.373 | 0.114 | 322 | 258 |
– | 175 | 0.347 | 0.106 | 337 | 270 |
– | 300 | 0.308 | 0.0938 | 343 | 290 |
Oak | – | 0.282 | 0.0859 | 384 | 307 |
– | – | 0.282 | 0.086 | 385 | 307 |
Mulberry | – | 0.222 | 0.0676 | 448 | 356 |
Ash | – | 0.185 | 0.0565 | 501 | 398 |
Elm | – | 0.159 | 0.048 | 553 | 438 |
Poplar | – | 0.14 | 0.0427 | 598 | 473 |
– | – | 0.124 | 0.0337 | 647 | 511 |
Sycamore | – | 0.111 | 0.0377 | 694 | 547 |
Upas | – | 0.0925 | 0.0282 | 776 | 610 |
– | – | 0.0794 | 0.0242 | 854 | 669 |
Yew | – | 0.0698 | 0.0213 | 925 | 723 |
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China 500mm2 DIN 48201 All Aluminum Alloy Conductor AAAC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular (all aluminium alloy conductor) AAAC Products
16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC
Cicada BS En 50182 All Aluminum Conductor AAC
Box 18.8mm2 BS En 50182 All Aluminum Alloy Conductor AAAC
BS En 50182 Totara All Aluminum Alloy Conductor AAAC Wire
Gnat BS En 50182 All Aluminum Conductor AAC
Mosquito BS215 All Aluminum Conductor AAC
Popular 740.8mcm AAAC Flint Conductor Products
Box 18.8mm2 BS En 50182 All Aluminum Alloy Conductor AAAC
2/0AWG ASTM B399 All Aluminum Alloy Conductor AAAC
Fir 50 mm2 All Aluminum Alloy Conductor AAAC
BS En 50182 All Aluminum Alloy Conductor AAAC Wire
BS En 50182 Upas All Aluminum Alloy Conductor AAAC Wire
Almond 25 mm2 Aluminum Alloy Conductor AAAC
Popular HENAN BAOFENG CABLE CO. Products
H07rn-F 4 Core Type 450/750V Epr/Pcp Trailing Rubber Cable
Bare Conductor ASTM Standard Narcissus 1272AWG AAC Overhead Transmission Line
0.6/1kv 4 Core Armoured Cable 120mm PVC Armoured Power Cable
Bare Overhead Conductor Electrical Cable PE Insulated ABC Cable
BS Standard Wolf ACSR Aluminium Conductor Steel Reinforced Conductor
Low Voltage ABC Aluminum Conductor Multi Core Cable Aerial Bundle Cable Size
Popular Ltd. Products
Hot Sale 450/750V 4mm2 Rvv PVC Insulated and Jacket Copper Conductor Wire
UL Building Wire PVC Insulated Copper Thw Wire 2/0 4/0 AWG
38/66kv Cu/XLPE/Cws/Lat/HDPE (PVC) Single Aluminium or Copper Core 240mm2 Power Cable
0.6/1kv 1 Core 1X35mm2 Al/XLPE/PVC Aluminum Power Cable
Duplex Triplex Quadruplex Service Drop AWG#6 Shepherd Overhead ABC Aerial Bundled Cable
Tags: (all aluminium alloy conductor) AAAC, 740.8mcm AAAC Flint Conductor, HENAN BAOFENG CABLE CO., Ltd.