0.6/1kv U1000 RO2V NFC 32-321 Standard Copper PVC Cables Single Core

0.6/1kv U1000 RO2V NFC 32-321 Standard Copper PVC Cables Single Core image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
Scope of application
System
This product is suitable for transmitting electric energy in power lines with AC 50Hz and rated voltage 0.6/1kV (system maximum voltage 1.2kV).
Occasion
Fixed laying in metallurgy, electric power, construction and other industries indoors, cable trenches, pipelines, direct burial and other places that do not need to withstand mechanical external force.
Features
The raw materials for product production are widely sourced and cheap, and are easy to process and manufacture.
The product is insulated with cross-linked polyethylene. Compared with PVC insulated cables, it has better insulation performance and canwithstand extremely high working temperatures, up to 90 degrees.
Standards compliant
Implementation standards
GB/T 12706.1-2020 Extruded insulated power cables and accessories with rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV ) )cable
additional standards
Usage features
Rated voltage
The rated voltage of power frequency AC is 0.6/1kV, and the maximum voltage of the AC system should not exceed 1.2kV.
Operating temperature
The maximum allowable long-term operating temperature of the cable conductor is 90°C; during a short circuit, the maximum temperature of the cable conductor does not exceed 250°C and the duration does not exceed 5 seconds.
ambient temperature
Minimum working environment temperature -15ºC.
Laying temperature
The laying temperature of cables should not be lower than 0ºC.
radius bend
The bending radius of single-core cables should be no less than 20 times the outer diameter of the cable, and the bending radius of multi-core cables should be no less than 15 times the outer diameter of the cable.
Product Identification
Core
1.Color identification When multi-core cables are marked with different colors, they must comply with the following regulations: 2-core cable: red, blue; 3-core cable:
yellow, green, red; 4-core cable: yellow, green, red, blue; 5-core cable Cable: yellow, green, red, blue, black (or determined by negotiation between the supplier and the buyer). The colors red, yellow and green are used for the main wire core. Blue is used for the neutral core. In order to avoid confusion with other colors, it is recommended to use light blue.
2. Digital identification When multi-core cables use digital identification, they must comply with the following regulations: 2-core cable: 0, 1; 3-core cable: 1, 2, 3; 4-core cable: 0, 1, 2, 3; 5-core cable :0,1,2,3,4. The numbers 1, 2, and 3 are used for the main core, and 0 is used for the neutral core. In a 5-core cable, the number “4” refers to the specific purpose conductor (including the grounding conductor). When the insulated cores are marked with numbers, the insulation should be of the same color and arranged according to the numbers. Numbers should be printed on the surface of the insulated core with Arabic numerals. The color of the numbers should be the same and have obvious contrast with the insulation color and the writing should be clear; the number signs should be repeated at equal intervals along the insulated core, and two adjacent sets of number signs should be Invert each other. When the logo consists of a single number, a dash should be placed below the number. If the The logo consists of two numbers, it should be arranged up and down and a dash should be placed below the subsequent numbers. The spacing between two adjacent sets of digital logos is d. Should be no larger than 50mm.
outer cortex
The outer sheath of the cable is usually black, but it can also be in colors other than black according to the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have continuous identification of the manufacturer’s name, product model and rated voltage . The manufacturer’s name identification can be Duplicate identification of manufacturer or trademark. The printed logo should be scratch-resistant and not fall off, and the printed content on the surface should be clearly legible. Note: The logo on the surface of the sheath can also add other logo contents according to the habits of the user or manufacturer.
Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils, and the delivery length of short-segment cables should not exceed 5% of the total delivery length, or cables of any length can be delivered according to mutual agreement.
Length error
Delivery length measurement error is ±0.5%
Rated voltage |
No,of CORES |
core ×cross secticn (MM) |
CONDUCTOR | CORE DIANETER (MM2) |
INSULATION THCKNESS (MM) |
BELT (MM) |
JACKET THICKNESS (MM) |
Reference outer diameter (MM) |
Reference weight (kg/km) |
DC RESISTANCE (Ω/KM) |
0.6/1KV | 1 | 1×10 | 7/1.35 | 4.05 | 0.7 | 20×0.20 | 1.4 | 8.9 | 152.7 | 1.83 |
1 | 1×16 | 7/1.66 | 4.98 | 0.7 | 20×0.20 | 1.4 | 9.9 | 208.2 | 1.15 | |
1 | 1×25 | 7/2.14 | 6.42 | 0.9 | 20×0.20 | 1.4 | 11.6 | 318.3 | 0.727 | |
1 | 1×35 | 7/2.52 | 7.56 | 0.9 | 20×0.20 | 1.4 | 12.8 | 418 | 0.524 | |
1 | 1×50 | 10/2.52 | 8.4 | 1 | 25×0.20 | 1.4 | 13.8 | 544 | 0.387 | |
1 | 1×70 | 14/2.52 | 10 | 1.1 | 30×0.20 | 1.4 | 15.6 | 736.7 | 0.268 | |
1 | 1×95 | 19/2.52 | 11.6 | 1.1 | 35×0.20 | 1.5 | 17.4 | 987.8 | 0.193 | |
1 | 1×120 | 24/2.52 | 13 | 1.2 | 40×0.20 | 1.5 | 19 | 1226.7 | 0.153 | |
1 | 1×150 | 30/2.52 | 14.6 | 1.4 | 45×0.20 | 1.6 | 21.2 | 1522.6 | 0.124 | |
1 | 1×185 | 37/2.52 | 16.2 | 1.6 | 50×0.20 | 1.6 | 23.2 | 1860 | 0.0991 | |
1 | 1×240 | 48/2.52 | 18.5 | 1.7 | 55×0.20 | 1.7 | 25.9 | 2386.3 | 0.0754 | |
1 | 1×300 | 61/2.52 | 20.6 | 1.8 | 60×0.20 | 1.8 | 28.4 | 3000.1 | 0.0601 | |
1 | 1×400 | 61/2.94 | 23.3 | 2 | 60×0.20 | 1.9 | 32.2 | 3870 | 0.047 | |
1 | 1×500 | 60/3.29 | 26.6 | 2.2 | 60×0.20 | 2 | 35.6 | 4951 | 0.0366 | |
1 | 1×630 | 60/3.69 | 29.6 | 2.4 | 60×0.20 | 2.2 | 39.4 | 6204.5 | 0.0283 |
We are China 0.6/1kv U1000 RO2V NFC 32-321 Standard Copper PVC Cables Single Core manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Henan Guowang Cable Group Co. Products
Copper Braid Shielding, Aluminum Foil Shielding Round Wire Electric PVC Cable
Turkey Code Swan Robin Bare Overhead ACSR Conductors with High Quality
H07V-R H07V-F H07V-K H07V-U PVC Insulation Flexible Stranded Cooper Electric Wire Cable 4mm 10mm 6mm
Self-Supporting Insulated Wire SIP-2 3X70+1X95 3X50+1X54.6+1X16 SIP-4 2X16 4X16
Low and Medium Voltage Cable Round Wire ASTM Standard Transmission Overhead
Copper CCC Approved Guowang China Wire IEC 60227 3X1.5 TPS Flat Cable in
Popular Ltd. Products
EV Charging Vehicles Cables AC Alternative Charging Cables
All Aluminum Conductor AAC Bare Conductor Stranded Cable Wire
600/1000V 4X240mm2 Yjv32 Cu/XLPE/PVC/Swa/PVC Armoured Power Cable XLPE Cable
Flat Cable BVVB 2X1.5mm2+E 2*2.5mm2+E Flat Twin and Earth Cable Electrical Wire
ASTM Standard Soft Medium Hard Drawn Bare Copper Conductor 4AWG
Underground Wire Copper Covered Steel CCS
Popular Power Cable Products
Underground Power Cable Copper Cu XLPE
XLPE Insulated Armoured Power Cable Manufacturer
House Wiring Flexible PVC Electrical Stranded Copper Wire
3X35mm2 Low Voltage Power Cable DIN VDE 0276 0.6/1kv Copper Cable
Overhead Bare Aluminum Conductor /AAC/ACSR/AAAC/Acar Cable 50mm2
Popular PVC Sheath Products
Copper Conductor, XLPE Insuated, Swa, PVC Sheath
XLPE XLPE/PVC Conductor Aluminum Cu/PVC Insulated Steel Wire Insulated Power Cable
Na2xy 0.6/1 Kv Aluminum Conductor, XLPE Insulated, PVC Sheath
Fire Resistant Electrical Cable AlXLPEPVC Power Cable
Orange Circular Cable, PVC Sheath, UV-Resistant 3G1.5 0.6/1kv (2 + E)
Steel Wire Armored Cu/PVC/Sta/Swa XLPE/PVC Aluminum Cu/Al Conductor Insulated Power Cable
Tags: Henan Guowang Cable Group Co., Ltd., Power Cable, PVC Sheath