Scope of application
System
This product is suitable for transmitting electric energy in power lines with AC 50Hz and rated voltage 0.6/1kV (system maximum voltage 1.2kV).
Occasion
Fixed laying in metallurgy, electric power, construction and other industries indoors, cable trenches, pipelines, direct burial and other places that do not need to withstand mechanical external force.
Product Characteristics
The raw materials for product production are widely sourced and cheap, and are easy to process and manufacture.
The product is insulated with cross-linked polyethylene. Compared with PVC insulated cables, it has better insulation performance and canwithstand extremely high working temperatures, up to 90 degrees.
The product is armored with steel wire and can withstand greater mechanical pressure.
The standard
Executive standard
GB/T 12706.1-2020 Extruded insulated power cables and accessories with rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV ) )cable
additional standards
Using features
Rated voltage
The rated voltage is 0.6/1kV, and the maximum voltage of the AC system should not exceed 1.2kV.
Operating temperature
The maximum allowable long-term operating temperature of the cable conductor is 90°C; In the case of short circuit, the maximum temperature of the cable conductor shall not exceed 250 ° C and the duration shall not exceed 5s.
ambient temperature
The minimum ambient temperature for cable operation is -15ºC.
Laying temperature
When installing and laying, the temperature should not be lower than 0ºC.
bending radius
The bending radius of single-core cables should be no less than 20 times the outer diameter of the cable, and the bending radius of multi-core cables should be no less than 15 times the outer diameter of the cable.
Product Identification
Core of cable
1.Color identification When multi-core cables are marked with different colors, they must comply with the following regulations: 2-core cable: red, blue; 3-core cable: yellow, green, red; 4-core cable: yellow, green, red, blue; 5-core cable Cable: yellow, green, red, blue, black (or determined by negotiation between the supplier and the buyer). The colors red, yellow and green are used for the main wire core. Blue is used for the neutral core. In order to avoid confusion with other colors, it is recommended to use light blue.
2. Digital identification When multi-core cables use digital identification, they must comply with the following regulations: 2-core cable: 0, 1; 3-core cable: 1, 2, 3; 4-core cable: 0, 1, 2, 3; 5-core cable :0,1,2,3,4. The numbers 1, 2, and 3 are used for the main core, and 0 is used for the neutral core. In a 5-core cable, the number “4” refers to the specific purpose conductor (including the grounding conductor). When the insulated cores are marked with numbers, the insulation should be of the same color and arranged according to the numbers. Numbers should be printed on the surface of the insulated core with Arabic numerals. The color of the numbers should be the same and have obvious contrast with the insulation color and the writing should be clear; the number signs should be repeated at equal intervals along the insulated core, and two adjacent sets of number signs should be Invert each other. When the logo consists of a single number, a dash should be placed
below the number. If the The logo consists of two numbers, it should be arranged up and down and a dash should be placed below the subsequent numbers. The spacing between two adjacent sets of digital logos is d. Should be no larger than 50mm.
Sheath
The outer sheath of the cable is usually black, but it can also be in colors other than black according to the manufacturer or buyer’s agreement to adapt to its use environment. The cable should have continuous identification of the manufacturer’s name, product model and rated voltage . The manufacturer’s name identification can be Duplicate identification of manufacturer or trademark. The printed logo should be scratch-resistant and not fall off, and the printed content on the surface should be clearly legible. Note: The logo on the surface of the sheath can also add other logo contents according to the habits of the user or manufacturer.
Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils, and the delivery length of short-segment cables should not exceed 5% of the total delivery length, or cables of any length can be delivered according to mutual agreement.
Delivery and Tolerance
Delivery length measurement error is ±0.5%
Rated voltage |
No,of CORES |
core ×cross secticn (MM) |
CONDUCTOR | CORE DIANETER (MM2) |
INSULATION THCKNESS (MM) |
BELT (MM) |
JACKET THICKNESS (MM) |
Reference outer diameter (MM) |
Reference weight (kg/km) |
DC RESISTANCE (Ω/KM) |
0.6/1KV | 1 | 1×10 | 7/1.35 | 4.1 | 0.7 | 20×0.20 | 1.4 | 8.9 | 89.7 | 3.08 |
1 | 1×16 | 7/1.66 | 5.0 | 0.7 | 20×0.20 | 1.4 | 9.9 | 112.9 | 1.91 | |
1 | 1×25 | 7/2.14 | 6.4 | 0.9 | 20×0.20 | 1.4 | 11.6 | 159.9 | 1.2 | |
1 | 1×35 | 7/2.52 | 7.6 | 0.9 | 25×0.20 | 1.4 | 12.8 | 198.2 | 0.868 | |
1 | 1×50 | 10/2.52 | 8.4 | 1.0 | 25×0.20 | 1.4 | 13.8 | 245 | 0.641 | |
1 | 1×70 | 14/2.52 | 10.0 | 1.1 | 30×0.20 | 1.4 | 15.6 | 318.2 | 0.443 | |
1 | 1×95 | 19/2.52 | 11.6 | 1.1 | 35×0.20 | 1.5 | 17.4 | 411.6 | 0.32 | |
1 | 1×120 | 24/2.52 | 13.0 | 1.2 | 40×0.20 | 1.5 | 19 | 498.9 | 0.253 | |
1 | 1×150 | 30/2.52 | 14.6 | 1.4 | 45×0.20 | 1.6 | 21.2 | 617.2 | 0.206 | |
1 | 1×185 | 37/2.52 | 16.2 | 1.6 | 50×0.20 | 1.6 | 23.2 | 743.4 | 0.164 | |
1 | 1×240 | 48/2.52 | 18.5 | 1.7 | 55×0.20 | 1.7 | 25.9 | 937.6 | 0.125 | |
1 | 1×300 | 61/2.52 | 20.6 | 1.8 | 60×0.20 | 1.8 | 28.4 | 1159.2 | 0.1 | |
1 | 1×400 | 61/2.94 | 23.3 | 2.0 | 60×0.20 | 1.9 | 32.2 | 1480.7 | 0.0778 | |
1 | 1×500 | 60/3.29 | 26.6 | 2.2 | 60×0.20 | 2.0 | 35.6 | 1864.6 | 0.0605 | |
1 | 1×630 | 60/3.69 | 29.6 | 2.4 | 60×0.20 | 2.2 | 39.4 | 2322 | 0.0469 |
We are China 0.6/1kv Single Core Aluminum Conductor PVC Insulation PVC Sheath Flame Retardant Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6/1kv Products
Good Price Industrial PVC 1.8kv Copper Core XLPE Manufacturer Supply Yjv Cable 0.6/1kv
Conductor, ABC, LV, 3X16+25 mm2, MDPE Cable UV Resistant, 0.6/1kv
0.6/1kv Copper Conductor XLPE Insulated PVC Sheathed Power Cable (YJV) 4*16mm, 4*50mm and 4*120mm
0.6/1kv Aluminum Conductor XLPE Insulation PVC Sheath Steel Wire Armoured Power Cable
0.6 1kv Cable, Copper Conductor XLPE Insulated Aluminum Wire Armoured PVC
Popular Aluminum Wire Products
Low Voltage Aerial Bundled Cable
Aluminum Cable 11kv 15kv 20kv 33kv 35kv High Voltage Cable
Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR
Multi Core Low Voltage Aerial Bundled Cable
Overhead Strand Aluminum AAC Conductor 73.6mm2
Ec Grade Aluminium Wire Rod 9.5mm for Electrical Purpose
Popular Henan Guowang Cable Group Co. Products
450/750V 16mm2 25mm2 35mm2 Welding Cable Flexible Copper Conductor Rubber Battery Cable
18/30kv Medium Voltage Cable Al-Rhz1-2ol 1X240 1X300 1X400 1X630
Low Smoke Free Halogen PVC Insulated Power Cable Underground Armoured Electrical Cable
6201 Bare All Aluminum Alloy Conductor AAAC ACSR Acar ACSR Bare Aluminum Core Overhead Cable
PVC Insulated Nylon Coated Building Light Wire Thhn Cable
Popular Ltd. Products
Flexible Single Core Copper Conductor Rubber Insulated Welding Cable H01n2-E
Copper UL Certificated Coils, Rolls or Drums Electric Cable PVC Insulation Wire
High Voltage XLPE Insulated Power Cable
Hot Sale High Quality Galvanized Steel Wire / Stay Wire / Guy Wire for Overhead
PVC Insulated Electric Wire Building Electric Copper Conductor
Tags: 0.6/1kv, Aluminum Wire, Henan Guowang Cable Group Co., Ltd.