0.6/1kv Low Voltage AAC ACSR AAAC ABC Cable XLPE/PE Insulation Overhead Aluminum Cable Aerial Bundled Electrical Cable for Power Transmission Line

China 0.6/1kv Low Voltage AAC ACSR AAAC ABC Cable XLPE/PE Insulation Overhead Aluminum Cable Aerial Bundled Electrical Cable for Power Transmission Line  manufacture and supplier

0.6/1kv Low Voltage AAC ACSR AAAC ABC Cable XLPE/PE Insulation Overhead Aluminum Cable Aerial Bundled Electrical Cable for Power Transmission Line image

Get Latest Price Request a quote

You May Like

Product Details

Model NO.
Low Voltage Abc Cable
Current
DC & AC
Insulation Material
PE
Sheath Material
PVC/XLPE/PE
Material Shape
Round Wire
Wire Core Material
Aluminum Alloy
Certification
ISO, CCC, CE, RoHS
Model
ABC Cable
Brand
Henway
Quality
High Quality
Standard
ASTM, BS, as, DIN, CSA, IEC, GB/T
Conductor Material
Aluminum Alloy
Transport Package
Wooden Drums, Steel-Wooden Drums, Steel Drums
Trademark
Henway
Origin
China
HS Code
7614900000
Production Capacity
10, 000, 000km Per Year

Product Description

Low Voltage Overhead Insulated Cable (ABC cable),Aerial bundle cable

Application: 

Aerial bundle cable is used primarily for overhead and distribution line, or to supply 120/220V aerial service for tem service at construction sites, as a service drop (power pole to service entrance) as a secondary cable (Pole to Pole), or street lighting. Working voltage at 600V and 1000V, ABC cable working temperature is 75ºC or 90ºC.

Applicable standards:

ABC cable are produced according to ANSI/ICEA S-70-547, ANSI/ICEA S-76-474, NFC 33-209, IEC60502-1, BS7870.50, VDE 027-626 GB/T12527 SANS1418 or the standards agreed by both of the customers and us. ICEA S-76-474 and NFC 33-209 are used widely.

Production Scope:

Voltage: 1KV and below.

Phase Core: 1 to 6 Cores, Cross section from 6AWG (13.3mm2) to 500MCM (253.4mm2).

Bare Neutral: Cross Section from 6AWG (13.3mm2) to 500MCM (253.4mm2)

Construction:

Phase Core:

Conductor: Hard bare copper wire /Aluminum wire/Aluminum alloy wire. etc.

Insulation: PVC/XLPE/PE

Neutral Conductor (optional):  ACSR /AAAC/AAC 

Insulation: PVC/XLPE/PE

Street Lighting core (optional):

Conductor: AAC

Insulation: PVC/XLPE/PE

* We can design and produce ABC cable according to client’s requirement.

Number of Cores x Nominal Cross Section,No.x mm2 Nominal Thickness of Insulation mm Approx Overall Diameter
mm
Approx. mass
Kg/Km
Maximum Conductor Resistance
Ω/Km
Minimum Breaking Load,KN Current Rating
A
Phase core Neutral core Lighting core
2×16  1.2 1.2 15 130 1.91 2.3 93
2×16 + 2×1.5  1.2 1.2 16 175 1.91 / 12.1
4×16 1.2 1.2 18 260 1.91 83
4×16 + 2×1.5  1.2 1.2 20 310 1.91 / 12.1
2×25  1.4 1.4 18 202 1.2 3.8 122
2×25 + 2×1.5  1.4 1.4 19.5 250 1.2 / 12.1
4×25  1.4 1.4 22 404 1.2 111
4×25 + 2×1.5  1.4 1.4 24 452 1.2/ 12.1
 3×35 +1×54.6 + K×16
(K can be 0,1,2,3)
1.6 1.6 1.2 28.5/29.5/31/33 620/685/750/815 0.868/0.63/1.91 16.6 138/83
3×50 +1×54.6 + K×16
(K can be 0,1,2,3)
1.6 1.6 1.2 30.5/32.5/34/36 740/805/870/935 0.641/0.63/1.91 165/83
 3×70  +1×54.6 + K×16
(K can be 0,1,2,3)
1.8 1.6 1.2 34.5/36/39/41 975/1040/1105/1170 0.868/0.63/1.91 213/83
 3×95 +1×70+K×16
(K can be 0,1,2,3)
1.8 1.5 1.2 37/39.5/42/44 1210/1275/1340/1405 0.32/0.50/1.91 20.5 258/83
 3×120 +1×70+K×16
(K can be 0,1,2,3)
1.8 1.5 1.2 38.5/40.5/43.5/46 1477/1542/1607/1672 0.253/0.50/1.91 300/83
 3×120 +1×95+K×16
(K can be 0,1,2,3)
1.8 1.6 1.2 39.5/41.5/44.5/47 1535/1600/1665/1730 0.253/0.343/1.91 27.5
 3×150 +1×70+K×16
(K can be 0,1,2,3)
1.7 1.5 1.2 40.5/42/44.5/48 1755/1820/1885/1950 0.206/0.50/1.91 20.5 344/83
 3×150 +1×95+K×16
 
(K can be 0,1,2,3)
1.7 1.6 1.2 43.2/45.3/47/49 1832/1897/1961/2026 0.206/0.343/1.91 27.5
Item# Phase Conductor Phase Conductor Insulation Bare Neutral Messenger Size AWG Bare Neutral Messenger Breaking Strength Weight Per 1000ft-XLPE Weight Per 1000ft-PE Ampacity-XLPE
A
Ampacity-PE
A
Bay 6 45mls 6 1110Lbs 145Lbs 140.0 Lbs 75 60
French coach 6 45mls 6 155Lbs 144.3 Lbs
German Coach 4 45mls 4 1760Lbs 214Lbs 208.3 Lbs 100 80
Arabian 4 45mls 4 229 Lbs 214.4 Lbs
Belgian 2 45mls 2 2800Lbs 344 Lbs 323.1 Lbs 135 105
Shetland 1/0 60mls 1/0 4460Lbs 546 Lbs 521.1 Lbs 180 140
Thoroughbred 2/0 60mls 2/0 5390Lbs 670 Lbs 641.5 Lbs 205 160
Trotter 3/0 60mls 3/0 6790Lbs 825 Lbs 791.8 Lbs 235 185
Walking 4/0 60mls 4/0 8560Lbs 1019 Lbs 979.7 Lbs 275 210

Products Pictures

Packing and loading containers pictures:

* We can design and produce ACSR according to client’s requirement. Any requirement, feel free to contact us!

Company Information


Certification


FAQ

1. Q:How does your factory control the quality?

A:Factory has a quick and enthusiastic merchandisers team, strict and responsible QC team, service for many well-known brands all around the world with our high-quality products and strict.

2. Q:Can I visit your company?

A: Sure,If you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?

A: Contact me on below,Determin sample and address for shipping.

4. Q:Have you ever supplied cables to our country?

A:  Henway Cables have been sold to over 100 countries and regions in the world. you can contact me for details.

5. Q:What is your MOQ?

A: MOQ Normally 500 meters for big diameter cables. Please contact me for detail info if you have specific cable requirement.

6.  Q:When can I get the price?

A: Usually quote within 6 hours after we get your inquiry.

7. Q:How long is your delivery time?

A: According to your order’s quantity. Usually our lead time is 3 – 20 working days.

 

For more information about wires and cables, please feel free to contact us. Your inquiries will be replied to within 6 hours!!

We are China 0.6/1kv Low Voltage AAC ACSR AAAC ABC Cable XLPE/PE Insulation Overhead Aluminum Cable Aerial Bundled Electrical Cable for Power Transmission Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 0.6/1kv Products

Control Cable 0.6/1kv High Quality

0.6/1kv LV PVC Insulated Single Phase Copper Aluminum Concentric Cable

High Quality Electric Wire Radiant Cross-Linked Polyolefin Insulated Power Cable of Rated Voltage 0.6/1kv Power Cable

French Type U1000 R2V RO2V Rvfv Copper Electric Power Installation Cable Wire

Duplex Triplex Quadruplex AAC AAAC ACSR 0.6/1kv ABC Cable Aluminum Conductor Aerial Bundled Overhead Cables

Pilot Communication Wire Sne Cne Airdac Cable

Popular Henway Electric Group Inc Products

TUV PV System Cable UV Resistant Wire H1z2z2-K PV1-F Xlpo Single Core Solar Cable Renewable Energy Wire Electrical Wire Electric Cable

Two Coresolar System Photovoltaic Flexible Copper PV Solar Panel Electrical Wire 2.5mm2 4mm2 6mm2 10mm2 DC Electric Solar Fiber Optic Cable

ACSR 153 Dorking Bare Aluminum Conductor Steel Reinforced Aluminium Conductors ACSR for 400kv Line Project (CSA49.1-1957)

1000V Concentric PVC Insulated Power Cable Nycwy Mcmk

BS. IEC. ASTM Standards Overhead Bare Aluminum Conductors AAC ACSR AAAC Acar Conductor

Factory Price Photovoltaic Solar Cable Wire H1z2z2-K 6mm2 DC Solar Cable for Solar Power Station/Solar Power System

Popular Service Drop Wire Products

Service Drop Wire Thriplex 2X2/0AWG+1/0AWG

3 Phases ABC Cable Low Voltage 600V Aerial Bundled Cable XLPE Insulation 4 Core ABC Conductors Cable Price

10 mm 35 mm 50mm 3 Phase Aluminium Conductor Triplex Service Drop Wire ABC Aerial Bundled Power Cable

0.6/1kv #2 #5 #6 Aerial Bundle Service Drop Wire XLPE ABC Aluminum Cable

0.6/1kv Service Drop Wire, Insulated Aerial Bundled Cable, ABC Cable

Aerial Cable 54.6mm2 Messenger Conductor Service Drop Wire Cable

Popular Products

0.6/1kv Multi Core Aluminum Conductor PVC Insulation PVC Sheath Steel Tape Armoured Power Cable

0.6/1kv Overhead 185mm2 185mm Price LV Amka-T Cables ABC Aerial Bundled Cable

Low Voltage Na2xs2y XLPE/PVC Sheath Al Power Cable

Conductor, ABC, LV, 3X95+70+16 mm2, MDPE Cable UV Resistant, 0.6/1kv

0.6/1kv Single Core Aluminum Conductor PVC Insulation PVC Sheath Flame Retardant Power Cable

Factory Price of 0.6/1kv Cu/XLPE/Swa/PVC Power Cable

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION